Literature DB >> 20510508

Lead(II) ion selective electrodes with PVC membranes based on two bis-thioureas as ionophores: 1,3-bis(N'-benzoylthioureido)benzene and 1,3-bis(N'-furoylthioureido)benzene.

Deivy Wilson1, María de los Angeles Arada, Salvador Alegret, Manel del Valle.   

Abstract

Two PVC membrane ion selective electrodes for Pb(II) ion based on two bis-thioureas: 1,3-bis(N'-benzoylthioureido)benzene and 1,3-bis(N'-furoylthioureido)benzene as ionophores, are reported. A first membrane formulated using 1,3-bis(N'-benzoylthioureido)benzene as carrier exhibited a Nernstian response to Pb(II) over a wide concentration range (4.0x10(-6) to 1.0x10(-2)M) with a slope of 31.5+/-1.6 mV/dec. It showed a fast response time (t(90%)=14 s) and could be used for 10 weeks without any divergence in potentials. The membrane formulated using 1,3-bis(N'-furoylthioureido)benzene as carrier exhibited a Nernstian response in the concentration range (5.0x10(-6) to 1.0x10(-2) M), with a slope of 30.0+/-1.3 mV/dec. Its response time was t(90%)=14 s, and it could be used for 14 weeks without any divergence in potentials. The two proposed potentiometric sensors revealed acceptable selectivities for Pb(II) over a wide variety of other metal ions and could be used in a pH range of 2.2-6.0. Both electrodes were assayed in direct potentiometric determination of lead in soils (10-30 mg/kg range) with very good performance (0.99935 correlation coefficient in the comparison against ICP-MS method). Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20510508     DOI: 10.1016/j.jhazmat.2010.04.107

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  4 in total

1.  A highly sensitive, selective and renewable carbon paste electrode based on a unique acyclic diamide ionophore for the potentiometric determination of lead ions in polluted water samples.

Authors:  M A Zayed; Walaa H Mahmoud; Ashraf A Abbas; Aya E Ali; Gehad G Mohamed
Journal:  RSC Adv       Date:  2020-05-06       Impact factor: 3.361

2.  1-(2-Furo-yl)-3-(2-meth-oxy-4-nitro-phen-yl)thio-urea.

Authors:  Seema Pratap; Durga P Singh; Sushil K Gupta; Sema Öztürk Yildirim; Ray J Butcher
Journal:  Acta Crystallogr Sect E Struct Rep Online       Date:  2013-02-02

3.  Dynamic potential and surface morphology study of sertraline membrane sensors.

Authors:  M M Khater; Y M Issa; H B Hassib; S H Mohammed
Journal:  J Adv Res       Date:  2014-12-01       Impact factor: 10.479

4.  3-Chloro-N-[N-(furan-2-carbon-yl)hydrazinocarbo-thio-yl]benzamide.

Authors:  Bohari M Yamin; Diyana Yusof; Siti Aishah Hasbullah
Journal:  Acta Crystallogr Sect E Struct Rep Online       Date:  2013-09-21
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.