Literature DB >> 20505225

Dosimetry measurements with an intra-operative x-ray device.

D J Eaton1, S Duck.   

Abstract

The INTRABEAM 50 kV x-ray device can be used for intra-operative partial breast irradiation. Spherical applicators are added to the source probe to deliver a radially symmetric radiation dose. Dosimetric data for calculation of absorbed dose were measured for this unit and a superficial unit with a similar beam quality, as defined by half value layer (HVL). Chamber calibration factors, N(K), and chamber correction factors, k(ch), were determined based on HVL, according to the IPEMB code of practice and addendum. Depth doses were also measured using an ionization chamber and GafChromic EBT film. HVL was measured as 0.85-1.30 mm Al across the range of applicator sizes. Values for N(K) and k(ch) were found to be similar for the two units and all INTRABEAM applicator sizes. Therefore, calibration of ionization chambers, radiochromic film and other relative dosimeters could be performed on the superficial unit. This has the advantage of higher dose rates and lower dependence on small variations in detector positioning. Depth dose measurements performed using film also agreed with chamber values, published and manufacturer data, giving a simple and robust method for commissioning and regular quality assurance.

Entities:  

Mesh:

Year:  2010        PMID: 20505225     DOI: 10.1088/0031-9155/55/12/N02

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

1.  A national dosimetry audit of intraoperative radiotherapy.

Authors:  D J Eaton; B Earner; P Faulkner; N Dancer
Journal:  Br J Radiol       Date:  2013-10-16       Impact factor: 3.039

2.  Radiation protection for an intra-operative X-ray device.

Authors:  D J Eaton; R Gonzalez; S Duck; M Keshtgar
Journal:  Br J Radiol       Date:  2011-02-08       Impact factor: 3.039

Review 3.  Electronic brachytherapy--current status and future directions.

Authors:  D J Eaton
Journal:  Br J Radiol       Date:  2015-03-06       Impact factor: 3.039

4.  Dosimetric characteristics of the INTRABEAM ® system with spherical applicators in the presence of air gaps and tissue heterogeneities.

Authors:  Eyachew Misganew Tegaw; Somayeh Gholami; Gilnaz Omyan; Ghazale Geraily
Journal:  Radiat Environ Biophys       Date:  2020-03-31       Impact factor: 1.925

5.  The Effects on Absorbed Dose Distribution in Intraoral X-ray Imaging When Using Tube Voltages of 60 and 70 kV for Bitewing Imaging.

Authors:  Kristina Hellén-Halme; Mats Nilsson
Journal:  J Oral Maxillofac Res       Date:  2013-10-01

Review 6.  Present state and issues in IORT Physics.

Authors:  Frank W Hensley
Journal:  Radiat Oncol       Date:  2017-01-27       Impact factor: 3.481

7.  Therapeutic analysis of Intrabeam-based intraoperative radiation therapy in the treatment of unicentric breast cancer lesions utilizing a spherical target volume model.

Authors:  Madeline Schwid; Eric D Donnelly; Hualin Zhang
Journal:  J Appl Clin Med Phys       Date:  2017-07-25       Impact factor: 2.102

8.  Evaluation of the Effect of Source Geometry on the Output of Miniature X-ray Tube for Electronic Brachytherapy through Simulation.

Authors:  B Barati; M Zabihzadeh; M J Tahmasebi Birgani; N Chegini; J Fatahiasl; I Mirr
Journal:  J Biomed Phys Eng       Date:  2018-03-01

9.  A novel approach for superficial intraoperative radiotherapy (IORT) using a 50 kV X-ray source: a technical and case report.

Authors:  Frank Schneider; Sven Clausen; Johannes Thölking; Frederik Wenz; Yasser Abo-Madyan
Journal:  J Appl Clin Med Phys       Date:  2014-01-06       Impact factor: 2.102

10.  INTRABEAM intraoperative radiotherapy combined with portal vein infusion chemotherapy for treating hepatocellular carcinoma with portal vein tumor thrombus.

Authors:  Xiaodong Song; Yong He; Huihong Liang; Menling Han; Zili Shao
Journal:  BMC Surg       Date:  2020-08-01       Impact factor: 2.102