Literature DB >> 20493653

Clinical and angiographic outcomes after treatment of de novo coronary stenoses with a novel platinum chromium thin-strut stent: primary results of the PERSEUS (Prospective Evaluation in a Randomized Trial of the Safety and Efficacy of the Use of the TAXUS Element Paclitaxel-Eluting Coronary Stent System) trial.

Dean J Kereiakes1, Louis A Cannon, Robert L Feldman, Jeffrey J Popma, Raymond Magorien, Robert Whitbourn, Ira M Dauber, Abram C Rabinowitz, Michael W Ball, Barry Bertolet, Ameer Kabour, Michael C Foster, John C Wang, Paul Underwood, Keith D Dawkins.   

Abstract

OBJECTIVES: The aim of this study was to evaluate the safety and efficacy of the novel platinum chromium TAXUS Element paclitaxel-eluting stent (PES) compared with the TAXUS Express PES (Boston Scientific, Natick, Massachusetts) in treating coronary artery stenoses.
BACKGROUND: The TAXUS Element is a novel thin-strut (81 microm), platinum chromium alloy PES designed to improve radial strength, radiopacity, and deliverability, while safely providing comparable restenosis benefit compared with a previous-generation PES.
METHODS: The PERSEUS (Prospective Evaluation in a Randomized Trial of the Safety and Efficacy of the Use of the TAXUS Element Paclitaxel-Eluting Coronary Stent System) Workhorse (WH) trial is a prospective, randomized (3:1), controlled, multicenter study of the TAXUS Element (vs. TAXUS Express) PES for the treatment of de novo coronary atherosclerotic lesions<or=28 mm in length in reference vessels>or=2.75 to <or=4.0 mm in diameter. The primary end point was the 12-month rate of target lesion failure, and the secondary end point was 9-month angiographic in-segment percentage diameter stenosis. The study was powered to demonstrate noninferiority to TAXUS Express for both end points.
RESULTS: The intent-to-treat analysis included 1,262 patients (320 TAXUS Express, 942 TAXUS Element). The TAXUS Element was noninferior to TAXUS Express with respect to both the incidence of target lesion failure (5.57% vs. 6.14%, respectively; difference: 0.57%; 95% credible interval: 1.85%; Bayesian posterior probability of noninferiority=0.9996) and percentage diameter stenosis (ln[%DS] 3.09 vs. 3.12, respectively; difference: 0.03; 95% credible interval: 0.11; Bayesian posterior probability of noninferiority=0.9970). No differences in clinical outcomes to 12 months were observed between stent treatments, and stent thrombosis was infrequent (0.3% Express, 0.4% Element).
CONCLUSIONS: At 1 year, the TAXUS Element is comparable in efficacy to the TAXUS Express PES. Furthermore, no safety concerns related to the novel platinum chromium alloy or stent design were observed. (A Prospective Evaluation in a Randomized Trial of the Safety and Efficacy of the Use of the TAXUS Element Paclitaxel-Eluting Coronary Stent System for the Treatment of De Novo Coronary Artery Lesions; NCT00484315). Copyright (c) 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20493653     DOI: 10.1016/j.jacc.2010.04.011

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  12 in total

Review 1.  Restenosis after PCI. Part 2: prevention and therapy.

Authors:  J Wouter Jukema; Tarek A N Ahmed; Jeffrey J W Verschuren; Paul H A Quax
Journal:  Nat Rev Cardiol       Date:  2011-10-11       Impact factor: 32.419

2.  Interventional cardiology: Promising improvements in DES technology.

Authors:  Bryony M Mearns
Journal:  Nat Rev Cardiol       Date:  2010-09       Impact factor: 32.419

3.  Comparison of vascular responses after different types of second-generation drug-eluting stents implantation detected by optical coherence tomography.

Authors:  Hirofumi Ohtani; Shigeki Kimura; Tomoyo Sugiyama; Keiichi Hishikari; Toru Misawa; Masafumi Mizusawa; Kazuto Hayasaka; Yosuke Yamakami; Keisuke Kojima; Yuichiro Sagawa; Hiroyuki Hikita; Takashi Ashikaga; Atsushi Takahashi; Mitsuaki Isobe
Journal:  Int J Cardiovasc Imaging       Date:  2016-10-19       Impact factor: 2.357

4.  [New developments in drug-eluting stents].

Authors:  M Kollum; C Bode
Journal:  Herz       Date:  2011-05       Impact factor: 1.443

Review 5.  Novel drug-eluting stents in the treatment of de novo coronary lesions.

Authors:  Davide Capodanno; Fabio Dipasqua; Corrado Tamburino
Journal:  Vasc Health Risk Manag       Date:  2011-02-25

6.  Influence of metal alloy and the profile of coronary stents in patients with multivessel coronary disease.

Authors:  Luciano Maurício de Abreu Filho; Antonio Artur da Cruz Forte; Marcos Kiyoshi Sumita; Desidério Favarato; George Cesar Ximenes Meireles
Journal:  Clinics (Sao Paulo)       Date:  2011       Impact factor: 2.365

7.  New stent design for use in small coronary arteries during percutaneous coronary intervention.

Authors:  Juan F Granada; Barbara A Huibregtse; Keith D Dawkins
Journal:  Med Devices (Auckl)       Date:  2010-10-19

8.  Safety and efficacy outcomes of first and second generation durable polymer drug eluting stents and biodegradable polymer biolimus eluting stents in clinical practice: comprehensive network meta-analysis.

Authors:  Eliano P Navarese; Kenneth Tandjung; Bimmer Claessen; Felicita Andreotti; Mariusz Kowalewski; David E Kandzari; Dean J Kereiakes; Ron Waksman; Laura Mauri; Ian T Meredith; Aloke V Finn; Hyo-Soo Kim; Jacek Kubica; Harry Suryapranata; Toni Mustahsani Aprami; Giuseppe Di Pasquale; Clemens von Birgelen; Elvin Kedhi
Journal:  BMJ       Date:  2013-11-06

Review 9.  Nanoparticle drug- and gene-eluting stents for the prevention and treatment of coronary restenosis.

Authors:  Rui-Xing Yin; De-Zhai Yang; Jin-Zhen Wu
Journal:  Theranostics       Date:  2014-01-08       Impact factor: 11.556

Review 10.  Advances in stent technologies and their effect on clinical efficacy and safety.

Authors:  Navin Nikam; Toby B Steinberg; Daniel H Steinberg
Journal:  Med Devices (Auckl)       Date:  2014-06-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.