Literature DB >> 20491822

Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature.

Jan D'haese1, Tommie Van De Velde, Ai Komiyama, Margaretha Hultin, Hugo De Bruyn.   

Abstract

BACKGROUND: In the last decade several stereolithographic guided surgery systems were introduced to the market. In this context, scientific information regarding accuracy of implant placement and surgical and prosthodontical complications is highly relevant as it provides evidence to implement this surgical technique in a clinical setting.
PURPOSE: To review data on accuracy and surgical and prosthodontical complications using stereolithographical surgical guides for implant rehabilitation.
MATERIAL AND METHODS: PubMed database was searched using the following keywords: "three dimensional imaging,""image based surgery,""flapless guided surgery,""customized drill guides,""computer assisted surgery,""surgical template," and "stereolithography." Only papers in English were selected. Additional references found through reading of selected papers completed the list.
RESULTS: In total 31 papers were selected. Ten reported deviations between the preoperative implant planning and the postoperative implant locations. One in vitro study reported a mean apical deviation of 1.0 mm, three ex vivo studies a mean apical deviation ranging between 0.6 and 1.2 mm. In six in vivo studies an apical deviation between 0.95 and 4.5 mm was found. Six papers reported on complications mounting to 42% of the cases when stereolithographic guided surgery was combined with immediate loading.
CONCLUSION: Substantial deviations in three-dimensional directions are found between virtual planning and actually obtained implant position. This finding and additionally reported postsurgical complications leads to the conclusion that care should be taken whenever applying this technique on a routine basis.
© 2010 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20491822     DOI: 10.1111/j.1708-8208.2010.00275.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  26 in total

1.  Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement.

Authors:  Wei Geng; Changying Liu; Yucheng Su; Jun Li; Yanmin Zhou
Journal:  Int J Clin Exp Med       Date:  2015-06-15

2.  Stereolithographic surgical template: a review.

Authors:  Shilpa Sudesh Dandekeri; M K Sowmya; Shruthi Bhandary
Journal:  J Clin Diagn Res       Date:  2013-09-10

3.  Calibrated segmentation of CBCT and CT images for digitization of dental prostheses.

Authors:  Veerle Wouters; Wouter Mollemans; Filip Schutyser
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-05-03       Impact factor: 2.924

4.  Implant Bed Preparation with an Erbium, Chromium Doped Yttrium Scandium Gallium Garnet (Er,Cr: YSGG) Laser Using Stereolithographic Surgical Guide.

Authors:  Gülin Seymen; Zeynep Turgut; Gizem Berk; Ayşen Bodur
Journal:  J Lasers Med Sci       Date:  2013

Review 5.  Flapless dental implant surgery and use of cone beam computer tomography guided surgery.

Authors:  D P Laverty; J Buglass; A Patel
Journal:  Br Dent J       Date:  2018-04-06       Impact factor: 1.626

6.  Evaluation of accuracy in implant site preparation performed in single- or multi-step drilling procedures.

Authors:  Nadine Marheineke; Uta Scherer; Martin Rücker; Constantin von See; Björn Rahlf; Nils-Claudius Gellrich; Marcus Stoetzer
Journal:  Clin Oral Investig       Date:  2017-12-17       Impact factor: 3.573

Review 7.  3D imaging, 3D printing and 3D virtual planning in endodontics.

Authors:  Pratik Shah; B S Chong
Journal:  Clin Oral Investig       Date:  2018-01-12       Impact factor: 3.573

8.  [Research advances in the use of digital surgical guides in implantology].

Authors:  Xiao-Hua Wang; Ai-Peng Liu; Wen-Zheng Deng
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-02-01

9.  Accuracy of a cone beam computed tomography-guided surgical stent for orthodontic mini-implant placement.

Authors:  Jae-Jung Yu; Gyu-Tae Kim; Yong-Suk Choi; Eui-Hwan Hwang; Janghyun Paek; Seong-Hun Kim; John C Huang
Journal:  Angle Orthod       Date:  2011-08-29       Impact factor: 2.079

10.  Computer guided implantology accuracy and complications.

Authors:  Vincenzo Bruno; Mauro Badino; Francesco Riccitiello; Gianrico Spagnuolo; Massimo Amato
Journal:  Case Rep Dent       Date:  2013-09-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.