Literature DB >> 20488465

Use of a nonpledgeted suture technique is safe and efficient for aortic valve replacement.

Damien J LaPar1, Gorav Ailawadi, Castigliano M Bhamidipati, Mansher Singh, David Dare, John A Kern, Irving L Kron.   

Abstract

OBJECTIVE: The use of pledgeted sutures to secure the prosthetic valve to the annulus during aortic valve replacement is thought to decrease the incidence of paravalvular leak. We hypothesized that use of nonpledgeted sutures in aortic valve replacement would provide equivalent outcomes to those of a pledgeted suture technique.
METHODS: Between January 1995 and April 2009, a total of 802 patients (511 nonpledgeted, 291 pledgeted) underwent isolated aortic valve replacement, including 671 patients who underwent primary, isolated aortic valve replacement (412 nonpledgeted, 259 pledgeted). Preoperative risk, intraoperative findings, and postoperative complications, including operative mortality, were evaluated.
RESULTS: Operative mortalities in isolated AVR operations were similar at 2.5% and 3.1% (P>.66) for nonpledgeted and pledgeted groups, respectively. Paravalvular leak rates after aortic valve replacement were equivalent in nonpledgeted and pledgeted groups (0.8% vs 1.4%, respectively, P=.47). Reoperation for paravalvular leak was rare in both groups. Importantly, the nonpledgeted technique incurred significantly shorter aortic crossclamp time (58.1±0.3 minutes vs 61.6±0.4 minutes, P<.001) and cardiopulmonary bypass time (87.5±0.8 minutes vs 90.3±0.8 minutes, P=.02) than did the pledgeted technique.
CONCLUSIONS: A nonpledgeted suture technique offers an equivalent alternative to the traditional use of pledgets during aortic valve replacement, with no increase in paravalvular leak rate. This nonpledgeted suture technique provides a time efficient and safe approach to aortic valve replacement operations. Copyright Â
© 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20488465      PMCID: PMC3073056          DOI: 10.1016/j.jtcvs.2010.04.011

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  8 in total

1.  Repeat heart valve surgery: risk factors for operative mortality.

Authors:  J M Jones; H O'kane; D J Gladstone; M A Sarsam; G Campalani; S W MacGowan; J Cleland; G W Cran
Journal:  J Thorac Cardiovasc Surg       Date:  2001-11       Impact factor: 5.209

2.  Importance of implant technique on risk of major paravalvular leak (PVL) after St. Jude mechanical heart valve replacement: a report from the Artificial Valve Endocarditis Reduction Trial (AVERT).

Authors:  Lars Englberger; Hartzell V Schaff; W R Eric Jamieson; Elizabeth D Kennard; Kyung A Im; Richard Holubkov; Thierry P Carrel
Journal:  Eur J Cardiothorac Surg       Date:  2005-11-07       Impact factor: 4.191

3.  Factors associated with periprosthetic leakage following primary mitral valve replacement: with special consideration of the suture technique.

Authors:  J P Dhasmana; E H Blackstone; J W Kirklin; N T Kouchoukos
Journal:  Ann Thorac Surg       Date:  1983-02       Impact factor: 4.330

4.  Natural history of early aortic paraprosthetic regurgitation: a five-year follow-up.

Authors:  L S Rallidis; I E Moyssakis; I Ikonomidis; P Nihoyannopoulos
Journal:  Am Heart J       Date:  1999-08       Impact factor: 4.749

5.  Paraprosthetic leak: a complication of cardiac valve replacement.

Authors:  A Jindani; E M Neville; G Venn; B T Williams
Journal:  J Cardiovasc Surg (Torino)       Date:  1991 Jul-Aug       Impact factor: 1.888

6.  Reoperation for aortic valve periprosthetic leakage: identification of patients at risk and results of operation.

Authors:  D L Miller; J J Morris; H V Schaff; C J Mullany; R A Nishimura; T A Orszulak
Journal:  J Heart Valve Dis       Date:  1995-03

7.  Prevalence and severity of valvular aortic stenosis determined by Doppler echocardiography and its association with echocardiographic and electrocardiographic left ventricular hypertrophy and physical signs of aortic stenosis in elderly patients.

Authors:  W S Aronow; I Kronzon
Journal:  Am J Cardiol       Date:  1991-04-01       Impact factor: 2.778

8.  Risk of reoperation for aortic bioprosthesis dysfunction.

Authors:  Nicolas Jaussaud; Vlad Gariboldi; Roch Giorgi; Dominique Grisoli; Virginie Chalvignac; Franck Thuny; Alberto Riberi; Frederic Collart
Journal:  J Heart Valve Dis       Date:  2009-05
  8 in total
  3 in total

1.  Safety and Feasibility of a Nonpledgeted Suture Technique for Heart Valve Replacement.

Authors:  Patrick G Chan; Ernest G Chan; Laura Seese; Ibrahim Sultan; Arman Kilic; Thomas G Gleason; Danny Chu
Journal:  JAMA Surg       Date:  2019-03-01       Impact factor: 14.766

2.  Outcomes of nonpledgeted horizontal mattress suture technique for mitral valve replacement.

Authors:  Gun Jik Kim; Jong Tae Lee; Young Ok Lee; Joon Young Cho; Tak-Hyuk Oh
Journal:  Korean J Thorac Cardiovasc Surg       Date:  2014-12-05

3.  Tear resistance of soft collagenous tissues.

Authors:  Kevin Bircher; Manuel Zündel; Marco Pensalfini; Alexander E Ehret; Edoardo Mazza
Journal:  Nat Commun       Date:  2019-02-15       Impact factor: 14.919

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.