Literature DB >> 1864881

Paraprosthetic leak: a complication of cardiac valve replacement.

A Jindani1, E M Neville, G Venn, B T Williams.   

Abstract

Paraprosthetic leak (PPL) is a rare but potentially serious complication of cardiac valve replacement. Between 1974 and 1988, 1175 prosthetic valves were implanted in 1026 patients by one cardiac surgeon at St. Thomas' Hospital, London. Of these 539 (52.5%) were aortic (AVR), 334 (32.6%) mitral (MVR), 7 (0.7%) tricuspid, and 144 (14%) AV and MV double valve replacements (DVR). There were only 2 triple valve replacements. The prosthetic valves implanted were the Starr-Edwards (7%), Bjork Shiley (11.8%), Lillehei-Kaster (23%), Carpentier-Edwards bioprosthesis (35.2%), Duromedics bileaflet (16.4%) and a variety of other mechanical and bioprosthetic valves (6.6%). Over the 15 year period there were a total of 82 (7%) valve failures of which PPL was diagnosed in 29 (2.5%) valves in 24 patients. Presenting features included cardiac decompensation in 72%, bacterial endocarditis in 12% and haemolytic anaemia in 12%. One patient (4%) had no symptoms. Nineteen patients underwent re-operation. Median time to re-operation was 15 months (range 1-65 months) with a re-operative mortality of 22%. Clinical evidence of prosthetic valve infection was found in 79% of MVR and 67% of AVR. A heavily calcified aortic annulus, found in 47% of patients, may also have contributed to PPL after AVR.

Entities:  

Mesh:

Year:  1991        PMID: 1864881

Source DB:  PubMed          Journal:  J Cardiovasc Surg (Torino)        ISSN: 0021-9509            Impact factor:   1.888


  23 in total

1.  Real-time three-dimensional TEE guidance of a paravalvular mitral valve leak closure procedure.

Authors:  N Wunderlich; J Franke; H Sievert
Journal:  Herz       Date:  2011-11-17       Impact factor: 1.443

2.  Repair of paravalvular prosthetic mitral valve leaks with septal occluder devices in severely high-risk patients: a word of caution.

Authors:  Craig R Smith; Sotiris C Stamou; William M Merhi; Robert L Hooker
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-05-28

3.  Three dimensional transesophageal echocardiography guided transcatheter closure of mitral paraprosthesis regurgitation - a case report.

Authors:  Vinay Kumar Sharma; S Radhakrishnan; Atul Mathur; Sameer Shrivastava
Journal:  Indian Heart J       Date:  2013-04-09

4.  Transapical septal occluder for paravalvular leakage of the mitral valve: a novel method for interventional treatment in high-risk patients.

Authors:  Karim Ibrahim; Marian Christoph; Joachim Nicolai; Hagen Schroetter; Thorsten Schmidt; Utz Kappert; Steffen Schoen; Ruth H Strasser
Journal:  Clin Res Cardiol       Date:  2011-06-05       Impact factor: 5.460

Review 5.  Percutaneous mitral and aortic paravalvular leak repair: indications, current application, and future directions.

Authors:  Ronald K Binder; John G Webb
Journal:  Curr Cardiol Rep       Date:  2013-03       Impact factor: 2.931

6.  Use of a nonpledgeted suture technique is safe and efficient for aortic valve replacement.

Authors:  Damien J LaPar; Gorav Ailawadi; Castigliano M Bhamidipati; Mansher Singh; David Dare; John A Kern; Irving L Kron
Journal:  J Thorac Cardiovasc Surg       Date:  2010-05-20       Impact factor: 5.209

7.  [Mechanical versus biological heart valves].

Authors:  J Ennker; A Lauruschkat
Journal:  Z Kardiol       Date:  2001-12

8.  Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiography.

Authors:  A Ionescu; A G Fraser; E G Butchart
Journal:  Heart       Date:  2003-11       Impact factor: 5.994

Review 9.  Acetyl-coenzyme A synthetase (AMP forming).

Authors:  V J Starai; J C Escalante-Semerena
Journal:  Cell Mol Life Sci       Date:  2004-08       Impact factor: 9.261

10.  Interventional closure of two fistulas after aortic valve surgery.

Authors:  Robert Dalla Pozza; R Kozlik-Feldmann; T-P Le; C Schmitz; R Sodian; B Reichart; Heinrich Netz
Journal:  Clin Res Cardiol       Date:  2009-04-09       Impact factor: 5.460

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.