Literature DB >> 20488325

Preliminary 3D computational analysis of the relationship between aortic displacement force and direction of endograft movement.

C Alberto Figueroa1, Charles A Taylor, Victoria Yeh, Allen J Chiou, Madhu L Gorrepati, Christopher K Zarins.   

Abstract

OBJECTIVE: Endograft migration is usually described as a downward displacement of the endograft with respect to the renal arteries. However, change in endograft position is actually a complex process in three-dimensional (3D) space. Currently, there are no established techniques to define such positional changes over time. The purpose of this study is to determine whether the direction of aortic endograft movement as observed in follow-up computed tomography (CT) scans is related to the directional displacement force acting on the endograft.
METHODS: We quantitated the 3D positional change over time of five abdominal endografts by determining the endograft centroid at baseline (postoperative scan) and on follow-up CT scans. The time interval between CT scans for the 5 patients ranged from 8 months to 8 years. We then used 3D image segmentation and computational fluid dynamics (CFD) techniques to quantitate the pulsatile displacement force (in Newtons [N]) acting on the endografts in the postoperative configurations. Finally, we calculated a correlation metric between the direction of the displacement force vector and the endograft movement by computing the cosine of the angle of these two vectors.
RESULTS: The average 3D movement of the endograft centroid was 18 mm (range, 9-29 mm) with greater movement in patients with longer follow-up times. In all cases, the movement of the endograft had significant components in all three spatial directions: Two of the endografts had the largest component of movement in the transverse direction, whereas three endografts had the largest component of movement in the axial direction. The magnitude and orientation of the endograft displacement force varied depending on aortic angulation and hemodynamic conditions. The average magnitude of displacement force for all endografts was 5.8 N (range, 3.7-9.5 N). The orientation of displacement force was in general perpendicular to the greatest curvature of the endograft. The average correlation metric, defined as the cosine of the angle between the displacement force and the endograft centroid movement, was 0.38 (range, 0.08-0.66).
CONCLUSIONS: Computational methods applied to patient-specific postoperative image data can be used to quantitate 3D displacement force and movement of endografts over time. It appears that endograft movement is related to the magnitude and direction of the displacement force acting on aortic endografts. These methods can be used to increase our understanding of clinical endograft migration. Copyright (c) 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20488325      PMCID: PMC2874723          DOI: 10.1016/j.jvs.2010.01.058

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  17 in total

Review 1.  Medical image registration.

Authors:  D L Hill; P G Batchelor; M Holden; D J Hawkes
Journal:  Phys Med Biol       Date:  2001-03       Impact factor: 3.609

2.  Quality of life endovascular and open AAA repair. Results of a randomised trial.

Authors:  M Prinssen; E Buskens; J D Blankensteijn
Journal:  Eur J Vasc Endovasc Surg       Date:  2004-02       Impact factor: 7.069

3.  Stent graft migration after endovascular aneurysm repair: importance of proximal fixation.

Authors:  Christopher K Zarins; Daniel A Bloch; Tami Crabtree; Alan H Matsumoto; Rodney A White; Thomas J Fogarty
Journal:  J Vasc Surg       Date:  2003-12       Impact factor: 4.268

4.  Magnitude and direction of pulsatile displacement forces acting on thoracic aortic endografts.

Authors:  C Alberto Figueroa; Charles A Taylor; Allen J Chiou; Victoria Yeh; Christopher K Zarins
Journal:  J Endovasc Ther       Date:  2009-06       Impact factor: 3.487

5.  Effect of curvature on displacement forces acting on aortic endografts: a 3-dimensional computational analysis.

Authors:  C Alberto Figueroa; Charles A Taylor; Victoria Yeh; Allen J Chiou; Christopher K Zarins
Journal:  J Endovasc Ther       Date:  2009-06       Impact factor: 3.487

6.  Geometrical enhancements for abdominal aortic stent-grafts.

Authors:  David S Molony; Anthony Callanan; Liam G Morris; Barry J Doyle; Michael T Walsh; Tim M McGloughlin
Journal:  J Endovasc Ther       Date:  2008-10       Impact factor: 3.487

7.  Iliac fixation inhibits migration of both suprarenal and infrarenal aortic endografts.

Authors:  Peyman Benharash; Jason T Lee; Oscar J Abilez; Tami Crabtree; Daniel A Bloch; Christopher K Zarins
Journal:  J Vasc Surg       Date:  2007-02       Impact factor: 4.268

8.  Computational fluid dynamics within bifurcated abdominal aortic stent-grafts.

Authors:  Benjamin A Howell; Tom Kim; Angela Cheer; Harry Dwyer; David Saloner; Timothy A M Chuter
Journal:  J Endovasc Ther       Date:  2007-04       Impact factor: 3.487

9.  Lateral movement of endografts within the aneurysm sac is an indicator of stent-graft instability.

Authors:  Benjamin Y Rafii; Oscar J Abilez; Peyman Benharash; Christopher K Zarins
Journal:  J Endovasc Ther       Date:  2008-06       Impact factor: 3.487

10.  A multicenter controlled clinical trial of open versus endovascular treatment of abdominal aortic aneurysm.

Authors:  Jon S Matsumura; David C Brewster; Michel S Makaroun; David C Naftel
Journal:  J Vasc Surg       Date:  2003-02       Impact factor: 4.268

View more
  8 in total

1.  Altered hemodynamics, endothelial function, and protein expression occur with aortic coarctation and persist after repair.

Authors:  Arjun Menon; Thomas J Eddinger; Hongfeng Wang; David C Wendell; Jeffrey M Toth; John F LaDisa
Journal:  Am J Physiol Heart Circ Physiol       Date:  2012-09-28       Impact factor: 4.733

2.  A Pilot Study Characterizing Flow Patterns in the Thoracic Aorta of Patients With Connective Tissue Disease: Comparison to Age- and Gender-Matched Controls via Fluid Structure Interaction.

Authors:  Joseph A Camarda; Ronak J Dholakia; Hongfeng Wang; Margaret M Samyn; Joseph R Cava; John F LaDisa
Journal:  Front Pediatr       Date:  2022-05-04       Impact factor: 3.569

3.  Treating a 20 mm Hg gradient alleviates myocardial hypertrophy in experimental aortic coarctation.

Authors:  David C Wendell; Ingeborg Friehs; Margaret M Samyn; Leanne M Harmann; John F LaDisa
Journal:  J Surg Res       Date:  2017-06-19       Impact factor: 2.192

4.  Endovascular ascending aortic repair in type A dissection: A systematic review.

Authors:  Yunus Ahmed; Ignas B Houben; C Alberto Figueroa; Nicholas S Burris; David M Williams; Frans L Moll; Himanshu J Patel; Joost A van Herwaarden
Journal:  J Card Surg       Date:  2020-11-10       Impact factor: 1.620

5.  Gene Expression in Experimental Aortic Coarctation and Repair: Candidate Genes for Therapeutic Intervention?

Authors:  John F LaDisa; Serdar Bozdag; Jessica Olson; Ramani Ramchandran; Judy R Kersten; Thomas J Eddinger
Journal:  PLoS One       Date:  2015-07-24       Impact factor: 3.240

6.  Deformation and dynamic response of abdominal aortic aneurysm sealing.

Authors:  L P Argani; F Torella; R K Fisher; R G McWilliams; M L Wall; A B Movchan
Journal:  Sci Rep       Date:  2017-12-18       Impact factor: 4.379

7.  Stent-graft surface movement after endovascular aneurysm repair: baseline parameters for prediction, and association with migration and stent-graft-related endoleaks.

Authors:  Ulrika Asenbaum; Maria Schoder; Ernst Schwartz; Georg Langs; Pascal Baltzer; Florian Wolf; Alexander M Prusa; Christian Loewe; Richard Nolz
Journal:  Eur Radiol       Date:  2019-06-27       Impact factor: 5.315

8.  Fast and Accurate Computation of the Displacement Force of Stent Grafts after Endovascular Aneurysm Repair.

Authors:  Ming Qing; Zhan Liu; Tinghui Zheng
Journal:  Bioengineering (Basel)       Date:  2022-09-06
  8 in total