Literature DB >> 2048543

MR examination of the knee: interpretation with multiscreen digital workstation vs hardcopy format.

J J Brown1, S C Malchow, W G Totty, A J Wilson, J K Lee, M W Vannier, R G Jost.   

Abstract

A multiscreen imaging workstation was compared with conventional hardcopy format for diagnostic interpretation of MR images of the knee. MR examinations from 30 patients were interpreted by two observers using film displayed both on a standard film panel alternator and an eight-screen digital workstation. Arthroscopic examination of these patients disclosed 30 meniscal tears and five anterior cruciate ligament tears in 28 patients. Two patients had normal arthroscopic examinations. The MR examinations were evaluated with a five-point confidence rating scale. Results were correlated with arthroscopic findings, and receiver-operating-characteristic curves were generated from these data. No significant difference was found between the areas under the receiver-operating-characteristic curves for film and digital display. The time required for image interpretation was greater when using the digital workstation than when using the film by a factor of approximately 2.7. Our data indicate that a multiscreen digital workstation can be used for interpreting MR examinations of the knee without impairment of diagnostic performance, but with increased time required for image interpretation when compared with radiographic film and a film panel alternator.

Entities:  

Mesh:

Year:  1991        PMID: 2048543     DOI: 10.2214/ajr.157.1.2048543

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  3 in total

1.  Diagnostic performance of liquid crystal and cathode-ray-tube monitors in brain computed tomography.

Authors:  Gerald Pärtan; Rudolf Mayrhofer; Michael Urban; Manfred Wassipaul; Ludwig Pichler; Walter Hruby
Journal:  Eur Radiol       Date:  2003-02-19       Impact factor: 5.315

2.  How many screens does a CT workstation need?

Authors:  D V Beard; B M Hemminger; K M Denelsbeck; R E Johnston
Journal:  J Digit Imaging       Date:  1994-05       Impact factor: 4.056

3.  Computed tomography interpretations with a low-cost workstation: a timing study.

Authors:  D V Beard; B M Hemminger; E D Pisano; K M Denelsbeck; D M Warshauer; M A Mauro; B Keefe; W H McCartney; C B Wilcox
Journal:  J Digit Imaging       Date:  1994-08       Impact factor: 4.056

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.