Literature DB >> 20483638

Assessment of resolution parameters for CID-based shotgun proteomic experiments on the LTQ-Orbitrap mass spectrometer.

Min-Sik Kim1, Kumaran Kandasamy, Raghothama Chaerkady, Akhilesh Pandey.   

Abstract

Shotgun proteomics has been used extensively for characterization of a number of proteomes. High-resolution Fourier transform mass spectrometry (FTMS) has emerged as a powerful tool owing to its high mass accuracy and resolving power. One of its major limitations, however, is that the confidence level of peptide identification and sensitivity cannot be maximized simultaneously. Although it is generally assumed that higher resolution is better for peptide identifications, the precise effect of varying resolution as a parameter on peptide identification has not yet been systematically evaluated. We used the Escherichia coli proteome and a standard 48 protein mix to study the effect of different resolution parameters on peptide identifications in the setting of a shotgun proteomics experiment on an LTQ-Orbitrap mass spectrometer. We observed a higher number of peptide-spectrum matches (PSMs) whenever the MS scan was carried out by FT and the MS/MS in the ion-trap (IT) with the maximum PSMs obtained at an MS resolution of 30,000. In contrast, when samples were analyzed by FT for both MS and MS/MS, the number of PSMs was significantly lower (approximately 40% compared with FT-IT experiments) with the maximum PSMs obtained when both the MS and MS/MS resolution were set to 15,000. Thus, a 15K-15K resolution setting may provide the best compromise for studies where both speed and accuracy such as high-throughput post-translational analysis and de novo sequencing are important. We hope that our study will allow researchers to choose between different resolution parameters to achieve their desired results from proteomic analyses. 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20483638      PMCID: PMC3030983          DOI: 10.1016/j.jasms.2010.04.011

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  24 in total

1.  Electrostatic axially harmonic orbital trapping: a high-performance technique of mass analysis

Authors: 
Journal:  Anal Chem       Date:  2000-03-15       Impact factor: 6.986

2.  Role of accurate mass measurement (+/- 10 ppm) in protein identification strategies employing MS or MS/MS and database searching.

Authors:  K R Clauser; P Baker; A L Burlingame
Journal:  Anal Chem       Date:  1999-07-15       Impact factor: 6.986

3.  Utility of accurate mass tags for proteome-wide protein identification.

Authors:  T P Conrads; G A Anderson; T D Veenstra; L Pasa-Tolić; R D Smith
Journal:  Anal Chem       Date:  2000-07-15       Impact factor: 6.986

4.  Factors that affect ion trap data-dependent MS/MS in proteomics.

Authors:  Brett R Wenner; Bert C Lynn
Journal:  J Am Soc Mass Spectrom       Date:  2004-02       Impact factor: 3.109

5.  TANDEM: matching proteins with tandem mass spectra.

Authors:  Robertson Craig; Ronald C Beavis
Journal:  Bioinformatics       Date:  2004-02-19       Impact factor: 6.937

6.  Open mass spectrometry search algorithm.

Authors:  Lewis Y Geer; Sanford P Markey; Jeffrey A Kowalak; Lukas Wagner; Ming Xu; Dawn M Maynard; Xiaoyu Yang; Wenyao Shi; Stephen H Bryant
Journal:  J Proteome Res       Date:  2004 Sep-Oct       Impact factor: 4.466

Review 7.  Proteomics by mass spectrometry: approaches, advances, and applications.

Authors:  John R Yates; Cristian I Ruse; Aleksey Nakorchevsky
Journal:  Annu Rev Biomed Eng       Date:  2009       Impact factor: 9.590

8.  Effect of dynamic exclusion duration on spectral count based quantitative proteomics.

Authors:  Ying Zhang; Zhihui Wen; Michael P Washburn; Laurence Florens
Journal:  Anal Chem       Date:  2009-08-01       Impact factor: 6.986

9.  Hybridization of pulsed-Q dissociation and collision-activated dissociation in linear ion trap mass spectrometer for iTRAQ quantitation.

Authors:  Tiannan Guo; Chee Sian Gan; Huoming Zhang; Yi Zhu; Oi Lian Kon; Siu Kwan Sze
Journal:  J Proteome Res       Date:  2008-10-07       Impact factor: 4.466

10.  NCBI Peptidome: a new public repository for mass spectrometry peptide identifications.

Authors:  Douglas J Slotta; Tanya Barrett; Ron Edgar
Journal:  Nat Biotechnol       Date:  2009-07       Impact factor: 54.908

View more
  14 in total

1.  Regulation of lipid metabolism by Dicer revealed through SILAC mice.

Authors:  Tai-Chung Huang; Nandini A Sahasrabuddhe; Min-Sik Kim; Derese Getnet; Yi Yang; Jonathan M Peterson; Bidyut Ghosh; Raghothama Chaerkady; Steven D Leach; Luigi Marchionni; G William Wong; Akhilesh Pandey
Journal:  J Proteome Res       Date:  2012-02-28       Impact factor: 4.466

2.  Optimization of mass spectrometric parameters improve the identification performance of capillary zone electrophoresis for single-shot bottom-up proteomics analysis.

Authors:  Zhenbin Zhang; Norman J Dovichi
Journal:  Anal Chim Acta       Date:  2017-11-14       Impact factor: 6.558

3.  Monoclonal antibody cocktail as an enrichment tool for acetylome analysis.

Authors:  Patrick G Shaw; Raghothama Chaerkady; Zhen Zhang; Nancy E Davidson; Akhilesh Pandey
Journal:  Anal Chem       Date:  2011-04-14       Impact factor: 6.986

4.  Systematic evaluation of alternating CID and ETD fragmentation for phosphorylated peptides.

Authors:  Min-Sik Kim; Jun Zhong; Kumaran Kandasamy; Bernard Delanghe; Akhilesh Pandey
Journal:  Proteomics       Date:  2011-05-20       Impact factor: 3.984

5.  Improving proteome coverage on a LTQ-Orbitrap using design of experiments.

Authors:  Genna L Andrews; Ralph A Dean; Adam M Hawkridge; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2011-02-15       Impact factor: 3.109

6.  Heterogeneity of pancreatic cancer metastases in a single patient revealed by quantitative proteomics.

Authors:  Min-Sik Kim; Yi Zhong; Shinichi Yachida; N V Rajeshkumar; Melissa L Abel; Arivusudar Marimuthu; Keshav Mudgal; Ralph H Hruban; Justin S Poling; Jeffrey W Tyner; Anirban Maitra; Christine A Iacobuzio-Donahue; Akhilesh Pandey
Journal:  Mol Cell Proteomics       Date:  2014-06-03       Impact factor: 5.911

7.  Multifactorial Understanding of Ion Abundance in Tandem Mass Spectrometry Experiments.

Authors:  Zeeshan Fazal; Bruce R Southey; Jonathan V Sweedler; Sandra L Rodriguez-Zas
Journal:  J Proteomics Bioinform       Date:  2013-01-29

Review 8.  Common errors in mass spectrometry-based analysis of post-translational modifications.

Authors:  Min-Sik Kim; Jun Zhong; Akhilesh Pandey
Journal:  Proteomics       Date:  2016-03       Impact factor: 3.984

9.  Evaluation and optimization of mass spectrometric settings during data-dependent acquisition mode: focus on LTQ-Orbitrap mass analyzers.

Authors:  Anastasia Kalli; Geoffrey T Smith; Michael J Sweredoski; Sonja Hess
Journal:  J Proteome Res       Date:  2013-05-31       Impact factor: 4.466

10.  Organophosphate Hydrolase Is a Lipoprotein and Interacts with Pi-specific Transport System to Facilitate Growth of Brevundimonas diminuta Using OP Insecticide as Source of Phosphate.

Authors:  Sunil Parthasarathy; Hari Parapatla; Aparna Nandavaram; Tracy Palmer; Dayananda Siddavattam
Journal:  J Biol Chem       Date:  2016-02-09       Impact factor: 5.157

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.