Literature DB >> 20462587

A study of the precision and accuracy of peak quantification in comprehensive two-dimensional liquid chromatography in time.

Dennis F Thekkudan1, Sarah C Rutan, Peter W Carr.   

Abstract

Simulated chromatographic data were used to determine the precision and accuracy in the estimation of peak volumes (i.e., peak sizes) in comprehensive two-dimensional liquid chromatography in time (LCxLC). Peak volumes were determined both by summing the areas in the second dimension chromatograms and by fitting the second dimension areas to a Gaussian peak. The Gaussian method is better at predicting the peak volume than the moments method provided there are at least three second dimension injections above the limit of detection (LOD). However, when only two of the second dimension signals are substantially above baseline, the accuracy and precision of the Gaussian fit method become quite poor because the results from the fitting algorithm become indeterminate. Based on simulations in which the modulation ratio (M(R)=4(1)sigma/t(s)) and sampling phase (phi) were varied, we conclude for well-resolved peaks that the optimum precision in peak volumes in 2D separations will be obtained when the M(R) is between two and five, such that there are typically four to ten second dimension peaks recorded over the eight sigma width of the first dimension peak. This sampling rate is similar to that suggested by the Murphy-Schure-Foley criterion. This provides an RSD of approximately 2% for the signal-to-noise ratio used in the present simulations. The precision of the peak volume of experimental data was also assessed, and RSD values were in the range of 4-5%. We conclude that the poorer precision found in the LCxLC experimental data as compared to LC may be due to experimental imprecision in sampling the effluent from the first dimension column. Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20462587      PMCID: PMC2914511          DOI: 10.1016/j.chroma.2010.04.039

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  46 in total

Review 1.  Comprehensive two-dimensional gas chromatography: a hyphenated method with strong coupling between the two dimensions.

Authors:  J B Phillips; J Beens
Journal:  J Chromatogr A       Date:  1999-09-24       Impact factor: 4.759

2.  Comprehensive two-dimensional gas chromatography with fast enantioseparation.

Authors:  Robert Shellie; Philip J Marriott
Journal:  Anal Chem       Date:  2002-10-15       Impact factor: 6.986

3.  Retention time reproducibility in comprehensive two-dimensional gas chromatography using cryogenic modulation an intralaboratory study.

Authors:  Robert A Shellie; Li-Ling Xie; Philip J Marriott
Journal:  J Chromatogr A       Date:  2002-08-30       Impact factor: 4.759

4.  Quantitation of suspected allergens in fragrances part II. Evaluation of comprehensive gas chromatography-conventional mass spectrometry.

Authors:  Christian Debonneville; Alain Chaintreau
Journal:  J Chromatogr A       Date:  2004-02-20       Impact factor: 4.759

5.  Effect of first-dimension undersampling on effective peak capacity in comprehensive two-dimensional separations.

Authors:  Joe M Davis; Dwight R Stoll; Peter W Carr
Journal:  Anal Chem       Date:  2007-12-13       Impact factor: 6.986

6.  Quantification in comprehensive two-dimensional liquid chromatography.

Authors:  Stephen E Reichenbach
Journal:  Anal Chem       Date:  2009-06-15       Impact factor: 6.986

7.  Approaches to comprehensive multidimensional liquid chromatography systems.

Authors:  Jacob N Fairchild; Krisztián Horváth; Georges Guiochon
Journal:  J Chromatogr A       Date:  2008-12-30       Impact factor: 4.759

8.  Accumulating resampling (modulation) in comprehensive two-dimensional capillary GC (GC x GC).

Authors:  Leonid M Blumberg
Journal:  J Sep Sci       Date:  2008-10       Impact factor: 3.645

9.  Equation for peak capacity estimation in two-dimensional liquid chromatography.

Authors:  Xiaoping Li; Dwight R Stoll; Peter W Carr
Journal:  Anal Chem       Date:  2009-01-15       Impact factor: 6.986

10.  Comprehensive two-dimensional liquid chromatography with ultraviolet, evaporative light scattering and mass spectrometric detection of triacylglycerols in corn oil.

Authors:  Elbert J C van der Klift; Gabriel Vivó-Truyols; Frank W Claassen; Frederique L van Holthoon; Teris A van Beek
Journal:  J Chromatogr A       Date:  2007-11-19       Impact factor: 4.759

View more
  2 in total

1.  Chemometric Resolution and Quantification of Four-Way Data Arising from Comprehensive 2D-LC-DAD Analysis of Human Urine.

Authors:  Hope P Bailey; Sarah C Rutan
Journal:  Chemometr Intell Lab Syst       Date:  2011-03-15       Impact factor: 3.491

2.  Investigation of interpolation techniques for the reconstruction of the first dimension of comprehensive two-dimensional liquid chromatography-diode array detector data.

Authors:  Robert C Allen; Sarah C Rutan
Journal:  Anal Chim Acta       Date:  2011-06-23       Impact factor: 6.558

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.