Literature DB >> 24013363

Chemometric Resolution and Quantification of Four-Way Data Arising from Comprehensive 2D-LC-DAD Analysis of Human Urine.

Hope P Bailey1, Sarah C Rutan.   

Abstract

Two-dimensional liquid chromatography (LC×LC) is quickly becoming an important technique for the analysis of complex samples, owing largely to the relatively high peak capacities attainable by this analytical technique. With the increase in the complexity of the sample comes a corresponding increase in the complexity of the collected data. Thus the need for chemometric methods capable of resolving and quantifying such data is ever more urgent in order to obtain the maximum information available from the data. To this end, we have developed a chemometric method that combines iterative key set factor analysis and multivariate curve resolution-alternating least squares analysis with a spectral selectivity constraint that is shown to be capable of resolving chromatographically rank deficient, non-multilinear data. (Spectrally rank deficient compounds can only be quantified if the peaks having the same spectra are chromatographically resolved.) Over 50 chromatographic peaks were found in a relatively small section of a LC×LC-diode array data set of replicate urine samples (a four-way data set) using the developed method. The relative concentrations for 34 of the 50 peaks were determined with % RSD values ranging from 0.09 % to 16 %.

Entities:  

Keywords:  2D liquid chromatography; alternating least squares; iterative key set factor analysis; multivariate curve resolution

Year:  2011        PMID: 24013363      PMCID: PMC3762254          DOI: 10.1016/j.chemolab.2010.07.008

Source DB:  PubMed          Journal:  Chemometr Intell Lab Syst        ISSN: 0169-7439            Impact factor:   3.491


  22 in total

Review 1.  Metabonomics technologies and their applications in physiological monitoring, drug safety assessment and disease diagnosis.

Authors:  John C Lindon; Elaine Holmes; Mary E Bollard; Elizabeth G Stanley; Jeremy K Nicholson
Journal:  Biomarkers       Date:  2004 Jan-Feb       Impact factor: 2.658

2.  Fast, comprehensive online two-dimensional high performance liquid chromatography through the use of high temperature ultra-fast gradient elution reversed-phase liquid chromatography.

Authors:  Dwight R Stoll; Jerry D Cohen; Peter W Carr
Journal:  J Chromatogr A       Date:  2006-05-23       Impact factor: 4.759

Review 3.  Fast, comprehensive two-dimensional liquid chromatography.

Authors:  Dwight R Stoll; Xiaoping Li; Xiaoli Wang; Peter W Carr; Sarah E G Porter; Sarah C Rutan
Journal:  J Chromatogr A       Date:  2007-08-30       Impact factor: 4.759

Review 4.  Metabolomics: a global biochemical approach to drug response and disease.

Authors:  Rima Kaddurah-Daouk; Bruce S Kristal; Richard M Weinshilboum
Journal:  Annu Rev Pharmacol Toxicol       Date:  2008       Impact factor: 13.820

5.  Quantification in comprehensive two-dimensional liquid chromatography.

Authors:  Stephen E Reichenbach
Journal:  Anal Chem       Date:  2009-06-15       Impact factor: 6.986

Review 6.  Metabolomics in pharmaceutical research and development: metabolites, mechanisms and pathways.

Authors:  Ethan Y Xu; William H Schaefer; Qiuwei Xu
Journal:  Curr Opin Drug Discov Devel       Date:  2009-01

7.  Probability of failure of the watershed algorithm for peak detection in comprehensive two-dimensional chromatography.

Authors:  Gabriel Vivó-Truyols; Hans-Gerd Janssen
Journal:  J Chromatogr A       Date:  2010-01-04       Impact factor: 4.759

8.  Quantification in comprehensive two-dimensional liquid chromatography.

Authors:  Luigi Mondello; Miguel Herrero; Tiina Kumm; Paola Dugo; Hernan Cortes; Giovanni Dugo
Journal:  Anal Chem       Date:  2008-06-03       Impact factor: 6.986

9.  Comprehensive two-dimensional liquid chromatography with on-line Fourier-transform-infrared-spectroscopy detection for the characterization of copolymers.

Authors:  S J Kok; Th Hankemeier; P J Schoenmakers
Journal:  J Chromatogr A       Date:  2005-09-06       Impact factor: 4.759

10.  Development and validation of a gas chromatography/mass spectrometry metabonomic platform for the global profiling of urinary metabolites.

Authors:  Kishore K Pasikanti; Paul C Ho; Eric C Y Chan
Journal:  Rapid Commun Mass Spectrom       Date:  2008-10       Impact factor: 2.419

View more
  3 in total

1.  Semi-automated alignment and quantification of peaks using parallel factor analysis for comprehensive two-dimensional liquid chromatography-diode array detector data sets.

Authors:  Robert C Allen; Sarah C Rutan
Journal:  Anal Chim Acta       Date:  2012-02-19       Impact factor: 6.558

Review 2.  Recent applications of chemometrics in one- and two-dimensional chromatography.

Authors:  Tijmen S Bos; Wouter C Knol; Stef R A Molenaar; Leon E Niezen; Peter J Schoenmakers; Govert W Somsen; Bob W J Pirok
Journal:  J Sep Sci       Date:  2020-03-19       Impact factor: 3.645

3.  Investigation of interpolation techniques for the reconstruction of the first dimension of comprehensive two-dimensional liquid chromatography-diode array detector data.

Authors:  Robert C Allen; Sarah C Rutan
Journal:  Anal Chim Acta       Date:  2011-06-23       Impact factor: 6.558

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.