Literature DB >> 2045946

Dynamic acquisition with a three-headed SPECT system: application to technetium 99m-SQ30217 myocardial imaging.

K Nakajima1, J Taki, H Bunko, M Matsudaira, A Muramori, I Matsunari, K Hisada, T Ichihara.   

Abstract

A method for SPECT data acquisition, "continuous repetitive rotation acquisition," was developed with a high-sensitivity three-headed SPECT system. The method was applied to the dynamic imaging of 99mTc-SQ30217, a new myocardial imaging agent. After acquisition and reconstruction of SPECT data every minute, projection images at arbitrary intervals were used for tomographic reconstruction to determine the best timing of SPECT imaging in 99mTc-SQ30217. Based on a comparison of several possible acquisition intervals, SPECT data acquisition within 9 min after injection is recommended because of high myocardial uptake (myocardium-to-lung ratio, 2.83 +/- 0.42 (mean +/- s.e.m.) at 3-6 min) and relatively low hepatic uptake (myocardium-to-liver ratio, 0.85 +/- 0.13 at 3-6 min). The rate constant of the clearance of 99mTc-SQ30217 from the myocardium obtained by SPECT was: k1 = 0.249 +/- 0.050 per min (average half-life = 2.8 min) and k2 = 0.012 +/- 0.004/min (average half-life = 58 min). The continuous repetitive rotation acquisition SPECT study appears useful for imaging SQ30217 with its rapidly changing myocardial distribution.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2045946

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  15 in total

1.  Analytical propagation of errors in dynamic SPECT: estimators, degrading factors, bias and noise.

Authors:  D J Kadrmas; E V DiBella; R H Huesman; G T Gullberg
Journal:  Phys Med Biol       Date:  1999-08       Impact factor: 3.609

2.  Technetium 99m-N-NOET: although not equivalent to thallium-201, it still offers new opportunities.

Authors:  A J Sinusas
Journal:  J Nucl Cardiol       Date:  2000 Mar-Apr       Impact factor: 5.952

3.  4D maximum a posteriori reconstruction in dynamic SPECT using a compartmental model-based prior.

Authors:  D J Kadrmas; G T Gullberg
Journal:  Phys Med Biol       Date:  2001-05       Impact factor: 3.609

Review 4.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

5.  Simultaneous assessment of cardiac perfusion and function using 5-dimensional imaging with Tc-99m teboroxime.

Authors:  Bing Feng; P Hendrik Pretorius; Troy H Farncombe; Seth T Dahlberg; Manoj V Narayanan; Miles N Wernick; Anna M Celler; Jeffrey A Leppo; Michael A King
Journal:  J Nucl Cardiol       Date:  2006 May-Jun       Impact factor: 5.952

6.  Assessment of reperfusion after acute myocardial infarction: is there a role for acute technetium 99m-teboroxime imaging?

Authors:  A J Sinusas
Journal:  J Nucl Cardiol       Date:  1996 Jan-Feb       Impact factor: 5.952

7.  Technetium 99m-labeled teboroxime: death in utero, infanticide, or failure to thrive?

Authors:  R J Burns
Journal:  J Nucl Cardiol       Date:  1995 Jan-Feb       Impact factor: 5.952

Review 8.  Multiheaded rotating gamma cameras in cardiac single-photon emission computed tomographic imaging.

Authors:  T L Faber
Journal:  J Nucl Cardiol       Date:  1994 May-Jun       Impact factor: 5.952

Review 9.  Experimental evaluation of radiotracers: role of intact biological models.

Authors:  A J Sinusas
Journal:  J Nucl Cardiol       Date:  1998 Mar-Apr       Impact factor: 5.952

Review 10.  Rationale for the rational development of new cardiac imaging agents.

Authors:  D D Miller
Journal:  Ann Nucl Med       Date:  1993-11       Impact factor: 2.668

View more