Literature DB >> 20458664

Equipment and operator training denote manual ventilation performance in neonatal resuscitation.

Charles C Roehr1, Marcus Kelm, Hans Proquitté, Gerd Schmalisch.   

Abstract

High peak inspiratory pressure (PIP) and tidal volume (V(T)) from manual ventilation are hazardous to the neonatal lung. We investigated the influence of operator training on the extent of applied PIP and V(T) between two manual ventilation devices. We performed a prospective, crossover study of 84 medical professionals using a neonatal mannequin. Participants were classified into four groups, according to experience in neonatal resuscitation and previous training in manual ventilation. Provision of PIP, V(T), and inspiratory time (Ti) were compared between groups and equipment used, either a self-inflating bag (SI-bag) or a T-piece resuscitator (Neopuff). Using SI-bags, operator training significantly affected provision of PIP ( P < 0.001), V(T) ( P < 0.001), and Ti ( P = 0.048). Using a T-piece device, PIP and V(T) provision was independent of operator training ( P = 0.55 and P = 0.66, respectively). Twenty-five participants (30%) had previous experience with T-piece devices; this correlated significantly with lower PIP and lower V(T) provision ( P > 0.001 for PIP and V(T)). Operator training level and device-specific experience had a significant impact on PIP and V(T) provision when using SI-bags for manual ventilation. For operators with no specific training in manual ventilation, use of T-piece devices is advised to control for excessive PIP and V(T) application. © Thieme Medical Publishers.

Entities:  

Mesh:

Year:  2010        PMID: 20458664     DOI: 10.1055/s-0030-1254236

Source DB:  PubMed          Journal:  Am J Perinatol        ISSN: 0735-1631            Impact factor:   1.862


  6 in total

1.  Influence of mask type and mask position on the effectiveness of bag-mask ventilation in a neonatal manikin.

Authors:  Philipp Deindl; Megan O'Reilly; Katharina Zoller; Angelika Berger; Arnold Pollak; Jens Schwindt; Georg M Schmölzer
Journal:  Eur J Pediatr       Date:  2013-08-11       Impact factor: 3.183

2.  Accuracy of a disposable compared to a non-disposable infant T-piece resuscitator.

Authors:  Vera B Krabbe; Jeroen J van Vonderen; Charles C Roehr; Arjan B Te Pas
Journal:  Eur J Pediatr       Date:  2014-02-16       Impact factor: 3.183

3.  Two-minute training for improving neonatal bag and mask ventilation.

Authors:  Jeroen J van Vonderen; Ruben S Witlox; Sascha Kraaij; Arjan B te Pas
Journal:  PLoS One       Date:  2014-10-03       Impact factor: 3.240

4.  Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator's Training.

Authors:  Cristiane do Prado; Ruth Guinsburg; Maria Fernanda Branco de Almeida; Renata Suman Mascaretti; Luciana Assis Vale; Luciana Branco Haddad; Celso Moura Rebello
Journal:  PLoS One       Date:  2016-02-09       Impact factor: 3.240

Review 5.  [Newborn resuscitation and support of transition of infants at birth].

Authors:  John Madar; Charles C Roehr; Sean Ainsworth; Hege Ersda; Colin Morley; Mario Rüdiger; Christiane Skåre; Tomasz Szczapa; Arjan Te Pas; Daniele Trevisanuto; Berndt Urlesberger; Dominic Wilkinson; Jonathan P Wyllie
Journal:  Notf Rett Med       Date:  2021-06-02       Impact factor: 0.892

6.  A Novel Prototype Neonatal Resuscitator That Controls Tidal Volume and Ventilation Rate: A Comparative Study of Mask Ventilation in a Newborn Manikin.

Authors:  Anne Lee Solevåg; Enrico Haemmerle; Sylvia van Os; Katinka P Bach; Po-Yin Cheung; Georg M Schmölzer
Journal:  Front Pediatr       Date:  2016-11-28       Impact factor: 3.418