This study employs optical coherence tomography (OCT) and ultrasound biomicroscopy (UBM) imaging as well as optical aberrometry to examine correlations between the anterior chamber angle aperture and visual acuity for near vision as well as coma along the horizontal and vertical axes in eyes implanted with an accommodative intraocular lens (Crystalens). A retrospective comparative consecutive case series of 22 eyes of 11 patients (5 males) uneventfully implanted with a Crystalens. Eyes with signs of posterior capsular opacification were excluded. All eyes were examined with 40 MHz UBM (Ellex Eyecubed) and spectral-domain OCT (Zeiss Visante). The angle aperture along the horizontal and vertical meridians was recorded based on the software of the systems. The coma root mean square (RMS) scores for the horizontal and vertical meridians were also recorded with the iTrace aberrometer. The anterior chamber angle was significantly wider along the horizontal axis compared with the vertical axis by UBM (46.37° and 44.20°, respectively) and by OCT (46.79° and 43.58°, respectively) (p = 0.02 in both cases, paired-samples t test). The correlations between the logMAR-converted Jaeger near vision score and the horizontal or vertical angle apertures was not statistically significant. Horizontal coma RMS was significantly inversely correlated with the horizontal angle aperture (r = -0.45, p = 0.03 and r = -0.39, p = 0.04 by OCT and UBM, respectively). Measurement of the horizontal angle aperture by the modalities used may represent an anatomical and clinical predictor of the optical aberrations induced by the Crystalens.

Entities:  

Mesh:

Year:  2013        PMID: 24166704     DOI: 10.1007/s10792-013-9872-x

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  18 in total

1.  Unilateral sulcus implantation of the crystalens HD.

Authors:  Ioannis G Pallikaris; Alexandra E Karavitaki; George D Kymionis; Georgios A Kontadakis; Sophia I Panagopoulou; George A Kounis
Journal:  J Refract Surg       Date:  2012-02-01       Impact factor: 3.573

2.  Near vision restoration with refractive lens exchange and pseudoaccommodating and multifocal refractive and diffractive intraocular lenses: comparative clinical study.

Authors:  Jorge L Alió; Marco Tavolato; Fernando De la Hoz; Pascual Claramonte; José-Luis Rodríguez-Prats; Ahmed Galal
Journal:  J Cataract Refract Surg       Date:  2004-12       Impact factor: 3.351

3.  Anterior segment imaging for glaucoma: OCT or UBM?

Authors:  Hiroshi Ishikawa
Journal:  Br J Ophthalmol       Date:  2007-11       Impact factor: 4.638

4.  Ultrasound biomicroscopy comparison of ab interno and ab externo scleral fixation of posterior chamber intraocular lenses.

Authors:  Ahmed M Kamal; Mervat Hanafy; Asser Ehsan; Reham H Tomerak
Journal:  J Cataract Refract Surg       Date:  2009-05       Impact factor: 3.351

5.  Objective accommodation measurements in prepresbyopic eyes using an autorefractor and an aberrometer.

Authors:  Dorothy M Win-Hall; Adrian Glasser
Journal:  J Cataract Refract Surg       Date:  2008-05       Impact factor: 3.351

6.  Influence of tilt and decentration of scleral-sutured intraocular lens on ocular higher-order wavefront aberration.

Authors:  T Oshika; G Sugita; K Miyata; T Tokunaga; T Samejima; C Okamoto; Y Ishii
Journal:  Br J Ophthalmol       Date:  2006-08-16       Impact factor: 4.638

7.  Anterior-segment imaging for assessment of glaucoma.

Authors:  Roxana Ursea; Ronald H Silverman
Journal:  Expert Rev Ophthalmol       Date:  2010-02-01

8.  Effects of accommodation training on accommodation and depth of focus in an eye implanted with a crystalens intraocular lens.

Authors:  Humza J Tahir; Jian L Tong; Sydney Geissler; Indu Vedamurthy; Clifton M Schor
Journal:  J Refract Surg       Date:  2010-10       Impact factor: 3.573

Review 9.  High-resolution ultrasound imaging of the eye - a review.

Authors:  Ronald H Silverman
Journal:  Clin Exp Ophthalmol       Date:  2008-12-09       Impact factor: 4.207

10.  Decentration and tilt of a single-piece aspheric intraocular lens compared with the lens position in young phakic eyes.

Authors:  Ulrich Mester; Thomas Sauer; Hakan Kaymak
Journal:  J Cataract Refract Surg       Date:  2009-03       Impact factor: 3.351

View more
  2 in total

1.  Assessment of Anterior Chamber by Ultrasound Biomicroscopy and Anterior Segment Optical Coherence Tomography in Patients with Inflammatory Glaucoma.

Authors:  Yiyong Qian; Lin Liu; Yuehui Shi; Minli Wang; Min Li; Jun Zou
Journal:  J Int Med Res       Date:  2019-10-08       Impact factor: 1.671

2.  Long-term visual outcomes after Crystalens(®) HD intraocular lens implantation.

Authors:  Alexandra E Karavitaki; Ioannis G Pallikaris; Sophia I Panagopoulou; George A Kounis; George Kontadakis; George D Kymionis
Journal:  Clin Ophthalmol       Date:  2014-05-22