Literature DB >> 20452143

Feasibility study for markerless tracking of lung tumors in stereotactic body radiotherapy.

Anne Richter1, Juergen Wilbert, Kurt Baier, Michael Flentje, Matthias Guckenberger.   

Abstract

PURPOSE: To evaluate the feasibility and accuracy of a method for markerless tracking of lung tumors in electronic portal imaging device (EPID) movies and to analyze intra- and interfractional variations in tumor motion. METHODS AND MATERIALS: EPID movies were acquired during stereotactic body radiotherapy (SBRT) given to 40 patients with 49 pulmonary targets and retrospectively analyzed. Tumor visibility and tracking accuracy were determined by three observers. Tumor motion of 30 targets was analyzed in detail via four-dimensional computed tomography (4DCT) and EPID in the superior-inferior direction for intra- and interfractional variations.
RESULTS: Tumor visibility was sufficient for markerless tracking in 47% of the EPID movies. Tumor size and visibility in the DRR were correlated with visibility in the EPID images. The difference between automatic and manual tracking was a maximum of 2 mm for 98.3% in the x direction and 89.4% in the y direction. Motion amplitudes in 4DCT images (range, 0.7-17.9 mm; median, 4.9 mm) were closely correlated with amplitudes in the EPID movies. Intrafractional and interfractional variability of tumor motion amplitude were of similar magnitude: 1 mm on average to a maximum of 4 mm. A change in moving average of more than ±1 mm, ±2 mm, and ±4 mm were observed in 47.1%, 17.1%, and 4.5% of treatment time for all trajectories, respectively. Mean tumor velocity was 3.4 mm/sec, to a maximum 61 mm/sec.
CONCLUSIONS: Tracking of pulmonary tumors in EPID images without implanted markers was feasible in 47% of all treatment beams. 4DCT is representative of the evaluation of mean breathing motion on average, but larger deviations occurred in target motion between treatment planning and delivery effort a monitoring during delivery. 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20452143     DOI: 10.1016/j.ijrobp.2009.11.028

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  25 in total

Review 1.  kV cone-beam CT-based IGRT: a clinical review.

Authors:  Judit Boda-Heggemann; Frank Lohr; Frederik Wenz; Michael Flentje; Matthias Guckenberger
Journal:  Strahlenther Onkol       Date:  2011-04-26       Impact factor: 3.621

Review 2.  Dynamic chest radiography: flat-panel detector (FPD) based functional X-ray imaging.

Authors:  Rie Tanaka
Journal:  Radiol Phys Technol       Date:  2016-06-13

3.  Scatter imaging during lung stereotactic body radiation therapy characterized with phantom studies.

Authors:  Kevin C Jones; Julius Turian; Gage Redler; Gizem Cifter; John Strologas; Alistair Templeton; Damian Bernard; James C H Chu
Journal:  Phys Med Biol       Date:  2020-08-10       Impact factor: 3.609

4.  Real-time soft tissue motion estimation for lung tumors during radiotherapy delivery.

Authors:  Joerg Rottmann; Paul Keall; Ross Berbeco
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

5.  2D/4D marker-free tumor tracking using 4D CBCT as the reference image.

Authors:  Mengjiao Wang; Gregory C Sharp; Simon Rit; Vivien Delmon; Guangzhi Wang
Journal:  Phys Med Biol       Date:  2014-04-08       Impact factor: 3.609

6.  A Bayesian approach for three-dimensional markerless tumor tracking using kV imaging during lung radiotherapy.

Authors:  Chun-Chien Shieh; Vincent Caillet; Michelle Dunbar; Paul J Keall; Jeremy T Booth; Nicholas Hardcastle; Carol Haddad; Thomas Eade; Ilana Feain
Journal:  Phys Med Biol       Date:  2017-03-21       Impact factor: 3.609

7.  Markerless EPID image guided dynamic multi-leaf collimator tracking for lung tumors.

Authors:  J Rottmann; P Keall; R Berbeco
Journal:  Phys Med Biol       Date:  2013-05-28       Impact factor: 3.609

8.  The impact of cine EPID image acquisition frame rate on markerless soft-tissue tracking.

Authors:  Stephen Yip; Joerg Rottmann; Ross Berbeco
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

9.  Beam's-eye-view imaging during non-coplanar lung SBRT.

Authors:  Stephen S F Yip; Joerg Rottmann; Ross I Berbeco
Journal:  Med Phys       Date:  2015-12       Impact factor: 4.071

10.  Technical Note: 3D localization of lung tumors on cone beam CT projections via a convolutional recurrent neural network.

Authors:  Chuang Wang; Margie Hunt; Lei Zhang; Andreas Rimner; Ellen Yorke; Michael Lovelock; Xiang Li; Tianfang Li; Gig Mageras; Pengpeng Zhang
Journal:  Med Phys       Date:  2020-01-28       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.