CONCLUSION: Patients implanted with the Digisonic® SP device showed better identification scores than those implanted with the Convex device, with skills continuing to improve over a longer time period. Technological improvements were beneficial in terms of speech perception in quiet. OBJECTIVE: To compare speech perception skills for post-lingually deaf patients implanted with a previous Neurelec device, the Digisonic® Convex, with those implanted with a more recent one, the Digisonic® SP, which provides more electrodes and a faster stimulation rate. METHODS: This was a retrospective study of 100 implanted patients, 45 with the Digisonic® Convex implant and 55 with the Digisonic® SP. Speech perception (dissyllabic words and sentences, in open set) was evaluated until 1 year after implantation. RESULTS: Patients fitted with the Digisonic® SP implant showed significantly better scores after 3, 6, and 12 months (mean scores: 53%, 62%, and 68% for words; 58%, 69%, and 75% for sentences) than those fitted with the Convex implant (34%, 42%, and 43% for words; 38%, 59%, and 51% for sentences). The improvement in speech perception after implantation for SP patients continued throughout the 12 months for words and 6 months for sentences, versus 6 months for words and 3 months for sentences for Convex patients.
CONCLUSION:Patients implanted with the Digisonic® SP device showed better identification scores than those implanted with the Convex device, with skills continuing to improve over a longer time period. Technological improvements were beneficial in terms of speech perception in quiet. OBJECTIVE: To compare speech perception skills for post-lingually deaf patients implanted with a previous Neurelec device, the Digisonic® Convex, with those implanted with a more recent one, the Digisonic® SP, which provides more electrodes and a faster stimulation rate. METHODS: This was a retrospective study of 100 implanted patients, 45 with the Digisonic® Convex implant and 55 with the Digisonic® SP. Speech perception (dissyllabic words and sentences, in open set) was evaluated until 1 year after implantation. RESULTS:Patients fitted with the Digisonic® SP implant showed significantly better scores after 3, 6, and 12 months (mean scores: 53%, 62%, and 68% for words; 58%, 69%, and 75% for sentences) than those fitted with the Convex implant (34%, 42%, and 43% for words; 38%, 59%, and 51% for sentences). The improvement in speech perception after implantation for SP patients continued throughout the 12 months for words and 6 months for sentences, versus 6 months for words and 3 months for sentences for Convex patients.
Authors: Carly A Anderson; Ian M Wiggins; Pádraig T Kitterick; Douglas E H Hartley Journal: Proc Natl Acad Sci U S A Date: 2017-08-14 Impact factor: 11.205
Authors: Alejandro Lopez Valdes; Myles Mc Laughlin; Laura Viani; Peter Walshe; Jaclyn Smith; Fan-Gang Zeng; Richard B Reilly Journal: PLoS One Date: 2014-03-05 Impact factor: 3.240