Literature DB >> 20441237

A monte carlo comparison of three different media for contrast enhanced radiotherapy of the prostate.

H M Garnica-Garza1.   

Abstract

Contrast-enhanced radiotherapy makes use of a kilovoltage X-ray beam, either from a diagnostic X-ray tube or modified megavoltage linear accelerator, in conjunction with a high-Z contrast medium deposited into the target volume to enhance the absorption of radiation. In this work, using the Monte Carlo code PENELOPE and the voxelized Zubal phantom to model a prostate radiotherapy treatment, a comparison between the physical absorbed dose distributions rendered by three different enhancing agents namely bismuth, gadolinium, and iodine is performed. It is assumed that there exists a concentration of 10 mg of enhancing agent per 1 g of tissue in the target volume while in the background a concentration of 1.5 mg per 1 g of tissue is present. The X-ray beam energy spectrum was obtained by means of Monte Carlo simulation of a tungsten target upon which a 220 keV mono-energetic electron pencil beam is made to impinge, and the resultant photon beam is heavily filtrated by 0.2 cm of copper. The treatment delivery is simulated as a 3608 arc collimated to conform to the target from every direction. Cumulative dose-volume histograms and isodose curves are presented for the target as well as five organs-at-risk, namely rectal wall, bladder, femoral heads, skin, and bone marrow. It is shown that under these conditions clinically acceptable treatment plans are obtained for all three contrast agents. A 72 Gy dose to 100% of the target volume results in maximum absorbed doses to the above mentioned organs-at-risk of 65, 56, 44, 32 and 65 Gy respectively when bismuth is used as the contrast agent, but the results obtained with gadolinium follow closely.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20441237     DOI: 10.1177/153303461000900306

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  4 in total

1.  Effect of anode angle on photon beam spectra and depth dose characteristics for X-RAD320 orthovoltage unit.

Authors:  Asghar Mesbahi; Seyed-Salman Zakariaee
Journal:  Rep Pract Oncol Radiother       Date:  2013-01-16

2.  The Effect of Contrast Material on Radiation Dose at CT: Part II. A Systematic Evaluation across 58 Patient Models.

Authors:  Pooyan Sahbaee; Ehsan Abadi; W Paul Segars; Daniele Marin; Rendon C Nelson; Ehsan Samei
Journal:  Radiology       Date:  2017-03-13       Impact factor: 11.105

3.  Contrast Medium Use in Computed Tomography for Patients Presenting with Headache: 4-year Retrospective Two-Center Study in Central and Western Regions of Ghana.

Authors:  Bashiru Babatunde Jimah; Benjamin Dabo Sarkodie; Asare Kwaku Offei; Ewurama Andam Idun; Dorothea Anim; Edmund Brakohiapa; Benard Ohene Botwe
Journal:  Radiol Res Pract       Date:  2022-10-04

4.  Comparison of dose calculations between pencil-beam and Monte Carlo algorithms of the iPlan RT in arc therapy using a homogenous phantom with 3DVH software.

Authors:  Jin Ho Song; Hun-Joo Shin; Chul Seung Kay; Soo-Min Chae; Seok Hyun Son
Journal:  Radiat Oncol       Date:  2013-12-05       Impact factor: 3.481

  4 in total