Literature DB >> 20440288

Standardization of HbA1c: good or bad?

Sally M Marshall1.   

Abstract

The development of a true reference measurement system by the International Federation for Clinical Chemistry (IFCC) for the first time allows reporting of true HbA(1c) results, standardized to an absolute value, worldwide. Regression equations between the IFCC assay and current harmonization assays, including the Diabetes Control and Complications Trial (DCCT) assay, are linear, tight, and stable over time. National and international setting of targets, audit and benchmarking of services will be easier than before, as will translation of research into clinical practice. Nevertheless, the main disadvantage of the IFCC assay is that the numbers and units reported (mmol/mol) are very different from the DCCT value (percentage). An extensive education program for patients and health-care professionals is, therefore, needed to prevent confusion and consequent deterioration in glycemic control. Furthermore, the IFCC system does not overcome difficulties inherent in the measurement and interpretation of HbA(1c), such as in the presence of abnormal turnover of red blood cells and hemoglobinopathies.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20440288     DOI: 10.1038/nrendo.2010.66

Source DB:  PubMed          Journal:  Nat Rev Endocrinol        ISSN: 1759-5029            Impact factor:   43.330


  20 in total

1.  Studies on the heterogeneity of hemoglobin. V. Binding of hemoglobin with oxidized glutathione.

Authors:  T H HUISMAN; A M DOZY
Journal:  J Lab Clin Med       Date:  1962-08

Review 2.  Development of a reference system for the international standardization of HbA1c/glycohemoglobin determinations.

Authors:  W Hoelzel; K Miedema
Journal:  J Int Fed Clin Chem       Date:  1996-06

3.  Recommendation for term and measurement unit for "HbA1c".

Authors:  Gunnar Nordin; René Dybkaer
Journal:  Clin Chem Lab Med       Date:  2007       Impact factor: 3.694

4.  Glycemic variability: the third component of the dysglycemia in diabetes. Is it important? How to measure it?

Authors:  Louis Monnier; Claude Colette; David R Owens
Journal:  J Diabetes Sci Technol       Date:  2008-11

5.  Hemoglobin H disease in two Iranian families.

Authors:  S Rahbar
Journal:  Clin Chim Acta       Date:  1968       Impact factor: 3.786

6.  Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus.

Authors:  David B Sacks; David E Bruns; David E Goldstein; Noel K Maclaren; Jay M McDonald; Marian Parrott
Journal:  Clin Chem       Date:  2002-03       Impact factor: 8.327

7.  The national glycohemoglobin standardization program: a five-year progress report.

Authors:  R R Little; C L Rohlfing; H M Wiedmeyer; G L Myers; D B Sacks; D E Goldstein
Journal:  Clin Chem       Date:  2001-11       Impact factor: 8.327

8.  Towards worldwide standardisation of HbA1c determination.

Authors:  K Miedema
Journal:  Diabetologia       Date:  2004-07-13       Impact factor: 10.122

9.  International Expert Committee report on the role of the A1C assay in the diagnosis of diabetes.

Authors: 
Journal:  Diabetes Care       Date:  2009-06-05       Impact factor: 17.152

10.  Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33). UK Prospective Diabetes Study (UKPDS) Group.

Authors: 
Journal:  Lancet       Date:  1998-09-12       Impact factor: 79.321

View more
  1 in total

1.  Emerging trends in optical sensing of glycemic markers for diabetes monitoring.

Authors:  Rishikesh Pandey; Narahara Chari Dingari; Nicolas Spegazzini; Ramachandra R Dasari; Gary L Horowitz; Ishan Barman
Journal:  Trends Analyt Chem       Date:  2015-01-01       Impact factor: 12.296

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.