Literature DB >> 15249996

Towards worldwide standardisation of HbA1c determination.

K Miedema1.   

Abstract

Haemoglobin A(1)c (HbA(1)c) or glycohaemoglobin is one of the most important parameters in the management of patients with diabetes mellitus, but to date there is no international standard for determining HbA(1)c. Most of the routine HbA(1)c assays are standardised against one of the local standardisation schemes like the NGSP (USA) and other schemes (Japan, Sweden). Still, results of HbA(1)c tests diverge considerably, as do the accompanying clinical decision limits. The IFCC Working Group on HbA(1)c Standardisation has developed a reference method and also set up a reference system for HbA(1)c, in which the analyte is defined as beta-N-glycated haemoglobin. This reference system consists of a network of reference laboratories that uses the reference methods and certified reference materials for optimal measurement of HbA(1)c in human blood. The main task of the network is to assign values to secondary reference materials, to be used by manufacturers of routine HbA(1)c assays to calibrate their assays. The high specificity of the reference method results in lower HbA(1)c values in blood samples, since the unspecific components falsely identified as HbA(1)c in routine methods are not measured by the reference method. The reference range for the new reference method was determined as 3 to 4% and the clinical decision limits were translated from existing guidelines: goal of treatment 5% HbA(1)c, change of therapy advised at HbA(1)c greater than 6%. Despite these lower values, worldwide implementation of the IFCC reference system for HbA(1)c is recommended, in order to end the great divergence in HbA(1)c results, with which physicians and patients are confronted today.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15249996     DOI: 10.1007/s00125-004-1453-0

Source DB:  PubMed          Journal:  Diabetologia        ISSN: 0012-186X            Impact factor:   10.122


  15 in total

1.  IFCC reference system for measurement of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study.

Authors:  Wieland Hoelzel; Cas Weykamp; Jan-Olof Jeppsson; Kor Miedema; John R Barr; Ian Goodall; Tadao Hoshino; W Garry John; Uwe Kobold; Randie Little; Andrea Mosca; Pierluigi Mauri; Rita Paroni; Fransiscus Susanto; Izumu Takei; Linda Thienpont; Masao Umemoto; Hsiao-Mei Wiedmeyer
Journal:  Clin Chem       Date:  2004-01       Impact factor: 8.327

Review 2.  Development of a reference system for the international standardization of HbA1c/glycohemoglobin determinations.

Authors:  W Hoelzel; K Miedema
Journal:  J Int Fed Clin Chem       Date:  1996-06

Review 3.  Endocrine (standardization of glycohemoglobin measurement).

Authors:  R R Little; D E Goldstein
Journal:  Anal Chem       Date:  1995-06-15       Impact factor: 6.986

4.  Candidate reference methods for hemoglobin A1c based on peptide mapping.

Authors:  U Kobold; J O Jeppsson; T Dülffer; A Finke; W Hoelzel; K Miedema
Journal:  Clin Chem       Date:  1997-10       Impact factor: 8.327

5.  Hemoglobin components in patients with diabetes mellitus.

Authors:  L A Trivelli; H M Ranney; H T Lai
Journal:  N Engl J Med       Date:  1971-02-18       Impact factor: 91.245

6.  Enzyme immunoassay--a new technique for estimating hemoglobin A1c.

Authors:  W G John; M R Gray; D L Bates; J L Beacham
Journal:  Clin Chem       Date:  1993-04       Impact factor: 8.327

7.  Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus.

Authors:  David B Sacks; David E Bruns; David E Goldstein; Noel K Maclaren; Jay M McDonald; Marian Parrott
Journal:  Clin Chem       Date:  2002-03       Impact factor: 8.327

8.  The national glycohemoglobin standardization program: a five-year progress report.

Authors:  R R Little; C L Rohlfing; H M Wiedmeyer; G L Myers; D B Sacks; D E Goldstein
Journal:  Clin Chem       Date:  2001-11       Impact factor: 8.327

9.  Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33). UK Prospective Diabetes Study (UKPDS) Group.

Authors: 
Journal:  Lancet       Date:  1998-09-12       Impact factor: 79.321

10.  Glycosylated minor components of human adult hemoglobin. Purification, identification, and partial structural analysis.

Authors:  M J McDonald; R Shapiro; M Bleichman; J Solway; H F Bunn
Journal:  J Biol Chem       Date:  1978-04-10       Impact factor: 5.157

View more
  19 in total

1.  Standardization of HbA1c: good or bad?

Authors:  Sally M Marshall
Journal:  Nat Rev Endocrinol       Date:  2010-05-04       Impact factor: 43.330

2.  How should HbA1c measurements be reported?

Authors:  F Gorus; C Mathieu; E Gerlo
Journal:  Diabetologia       Date:  2006-01       Impact factor: 10.122

3.  Teneligliptin, a Chemotype Prolyl-Thiazolidine-Based Novel Dipeptidyl Peptidase-4 Inhibitor with Insulin Sensitizing Properties.

Authors:  Eiji Kutoh; Asuka Wada; Sayaka Terayama
Journal:  Clin Drug Investig       Date:  2016-10       Impact factor: 2.859

4.  Evaluation of turbidimetric inhibition immunoassay (TINIA) and HPLC methods for glycated haemoglobin determination.

Authors:  Sema Genc; Beyhan Omer; Esra Aycan-Ustyol; Nurhan Ince; Fatih Bal; Figen Gurdol
Journal:  J Clin Lab Anal       Date:  2012-11       Impact factor: 2.352

5.  HbA1c standardisation destination--global IFCC Standardisation. How, why, where and when--a tortuous pathway from kit manufacturers, via inter-laboratory lyophilized and whole blood comparisons to designated national comparison schemes.

Authors:  Ian Goodall
Journal:  Clin Biochem Rev       Date:  2005-02

6.  Glycation isotopic labeling with 13C-reducing sugars for quantitative analysis of glycated proteins in human plasma.

Authors:  Feliciano Priego-Capote; Alexander Scherl; Markus Müller; Patrice Waridel; Frédérique Lisacek; Jean-Charles Sanchez
Journal:  Mol Cell Proteomics       Date:  2009-11-06       Impact factor: 5.911

7.  Glycated haemoglobin A1c for diagnosing diabetes in Chinese population: cross sectional epidemiological survey.

Authors:  Yuqian Bao; Xiaojing Ma; Huating Li; Mi Zhou; Cheng Hu; Haiya Wu; Junling Tang; Xuhong Hou; Kunsan Xiang; Weiping Jia
Journal:  BMJ       Date:  2010-05-17

8.  Validity of glycated hemoglobin in screening and diagnosing type 2 diabetes mellitus in Chinese subjects.

Authors:  Yun Yu; Xiao-Jun Ouyang; Qing-Lin Lou; Liu-Bao Gu; Yong-Zhen Mo; Gary T Ko; Chun-Chung Chow; Wing-Yee So; Ronald Ma; Alice Kong; Nicola Brown; Jennifer Nan; Juliana Chan; Rong-Wen Bian
Journal:  Korean J Intern Med       Date:  2012-02-28       Impact factor: 2.884

9.  Hemoglobin A1c as a diagnostic tool for diabetes screening and new-onset diabetes prediction: a 6-year community-based prospective study.

Authors:  Sung Hee Choi; Tae Hyuk Kim; Soo Lim; Kyong Soo Park; Hak C Jang; Nam H Cho
Journal:  Diabetes Care       Date:  2011-02-18       Impact factor: 19.112

10.  Correlation of same-visit HbA1c test with laboratory-based measurements: a MetroNet study.

Authors:  Kendra L Schwartz; Joseph C Monsur; Monina G Bartoces; Patricia A West; Anne Victoria Neale
Journal:  BMC Fam Pract       Date:  2005-07-13       Impact factor: 2.497

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.