Literature DB >> 20432314

Characterization and reduction of saturation banding in multiplanar coherent and incoherent steady-state imaging.

Jamal J Derakhshan1, Mark A Griswold, Sherif G Nour, Jeffrey L Sunshine, Jeffrey L Duerk.   

Abstract

Hypointense band artifacts occur at intersections of nonparallel imaging planes in rapidly acquired MR images; quantitative or numerical analysis of these bands and strategies to mitigate their appearance have largely gone unexplored. The magnetization evolution in the different regions of multiplanar images was simulated for three common rapid steady-state techniques (spoiled gradient echo, steady state free precession, balanced steady state free precession). Saturation banding was found to be highly dependent on the pulse sequence, acquisition time, and phase-encoding order. Encoding the center of k-space at the end of the acquisition of each slice (i.e., reverse centric phase encoding) is demonstrated to be a simple and robust method for significantly reducing the relative saturation in all imaging planes. View ordering and resolution dependence were confirmed in multiplanar abdominal images. The added importance of reducing the artifact in accelerated acquisition techniques (e.g., parallel imaging) is particularly notable in multiplanar balanced steady state free precession images in the brain. (c) 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20432314      PMCID: PMC5624045          DOI: 10.1002/mrm.22314

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

2.  On the transient phase of balanced SSFP sequences.

Authors:  Klaus Scheffler
Journal:  Magn Reson Med       Date:  2003-04       Impact factor: 4.668

Review 3.  Principles and applications of balanced SSFP techniques.

Authors:  Klaus Scheffler; Stefan Lehnhardt
Journal:  Eur Radiol       Date:  2003-08-20       Impact factor: 5.315

4.  FLASH imaging: rapid NMR imaging using low flip-angle pulses. 1986.

Authors:  A Haase; J Frahm; D Matthaei; W Hänicke; K-D Merboldt
Journal:  J Magn Reson       Date:  2011-12       Impact factor: 2.229

5.  Application of interlaced orientation slices in orthogonal planes for system characterization and as a basis for standardized brain sections in multiple-oblique positions.

Authors:  C Boesch; E Martin
Journal:  Magn Reson Med       Date:  1990-09       Impact factor: 4.668

6.  Steady-state magnetizations in rapid NMR imaging using small flip angles and short repetition intervals.

Authors:  K Sekihara
Journal:  IEEE Trans Med Imaging       Date:  1987       Impact factor: 10.048

7.  Signal strength in subsecond FLASH magnetic resonance imaging: the dynamic approach to steady state.

Authors:  W Hänicke; K D Merboldt; D Chien; M L Gyngell; H Bruhn; J Frahm
Journal:  Med Phys       Date:  1990 Nov-Dec       Impact factor: 4.071

8.  A technique for MRI-guided transrectal deep pelvic abscess drainage.

Authors:  Sherif Gamal Nour; Jamal J Derakhshan; Nila J Akhtar; Martin A Ayres; Mark E Clampitt; Thomas A Stellato; Jeffrey L Duerk
Journal:  AJR Am J Roentgenol       Date:  2008-10       Impact factor: 3.959

9.  A multi-plane scout sequence using flash imaging.

Authors:  S M Wright; R M Wright
Journal:  Magn Reson Imaging       Date:  1988 Mar-Apr       Impact factor: 2.546

10.  Interactive MR-guided biopsy in an open-configuration MR imaging system.

Authors:  S G Silverman; B D Collick; M R Figueira; R Khorasani; D F Adams; R W Newman; G P Topulos; F A Jolesz
Journal:  Radiology       Date:  1995-10       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.