Literature DB >> 20427392

False positive endoscopic ultrasound fine needle aspiration cytology: incidence and risk factors.

Ferga C Gleeson1, Benjamin R Kipp, Jill L Caudill, Jonathan E Clain, Amy C Clayton, Kevin C Halling, Michael R Henry, Elizabeth Rajan, Mark D Topazian, Kenneth K Wang, Maurits J Wiersema, Jun Zhang, Michael J Levy.   

Abstract

OBJECTIVE: It is broadly accepted that the false positive (FP) rate for endoscopic ultrasound fine needle aspiration (EUS FNA) is 0-1%. It was hypothesised that the FP and false suspicious (FS) rates for EUS FNA are greater than reported. A study was undertaken to establish the rate and root cause of discordant interpretation.
DESIGN: Using a prospectively maintained endoscopic database, cytohistological discordant EUS FNA examinations from 30 July 1996 to 31 December 2008 were identified retrospectively.
SETTING: Tertiary referral centre. MAIN OUTCOME MEASURES: Discordant FNA was defined by positive or suspicious FNA cytology in the absence of malignancy or neoplasm in the subsequent surgical pathology specimen, specifically in the absence of neoadjuvant therapy. Three cytopathologists conducted a blinded review of randomised discordant and matched specimens.
RESULTS: FNA was performed in 5667/18 066 (31.4%) patients undergoing EUS, of whom 2547 had cytology results interpreted as 'positive' or 'suspicious' or 'atypical' for malignancy or neoplasm. Subsequent surgical resection without prior neoadjuvant therapy was performed in 377 patients with positive or suspicious cytology. The FP rate was 20/377 (5.3%) and increased to 27/377 (7.2%) when FS cases were included. The incidence of discordance was consistent over time (1996-2002: 10/118 (8.6%) vs 2003-2008: 17/259 (6.6%); p=0.5) and was higher in non-pancreatic FNA (15%) than pancreatic FNA (2.2%; p=0.0001). Two-thirds of the non-pancreatic FP cases involved sampling of perioesophageal or perirectal nodes in patients with luminal neoplasms or Barrett's oesophagus. Following pathological re-review, discordance was attributed to translocated cell contamination/sampling error (50%) or cytopathologist interpretive error (50%).
CONCLUSIONS: These findings refute the accepted paradigm that FP cytology rarely occurs with EUS FNA. Further investigation revealed that FP FNA developed secondary to endosonographer technique or initial cytological misinterpretation, and is particularly likely when perioesophageal or perirectal nodes are aspirated in the setting of a luminal neoplasm or Barrett's oesophagus. Further study is needed to determine the significance of these findings and potential impact on the performance of FNA and patient outcomes.

Entities:  

Mesh:

Year:  2010        PMID: 20427392     DOI: 10.1136/gut.2009.187765

Source DB:  PubMed          Journal:  Gut        ISSN: 0017-5749            Impact factor:   23.059


  31 in total

Review 1.  Endoscopic Ultrasonography-Guided Biopsy for Differentiation of Benign and Malignant Pelvic Lesions: A Systematic Review and Meta-Analysis.

Authors:  Chaoqun Han; Rong Lin; Jun Liu; Xiaohua Hou; Wei Qian; Zhen Ding
Journal:  Dig Dis Sci       Date:  2015-09-04       Impact factor: 3.199

2.  Quality indicators for EUS.

Authors:  Sachin Wani; Michael B Wallace; Jonathan Cohen; Irving M Pike; Douglas G Adler; Michael L Kochman; John G Lieb; Walter G Park; Maged K Rizk; Mandeep S Sawhney; Nicholas J Shaheen; Jeffrey L Tokar
Journal:  Am J Gastroenterol       Date:  2014-12-02       Impact factor: 10.864

Review 3.  How to measure quality in endoscopic ultrasound.

Authors:  Antonio Facciorusso; Rosario Vincenzo Buccino; Nicola Muscatiello
Journal:  Ann Transl Med       Date:  2018-07

4.  The role of endoscopic ultrasound in biliary obstruction.

Authors:  Lennart Choo; Jason Conway; Girish Mishra
Journal:  Curr Gastroenterol Rep       Date:  2012-12

Review 5.  Ultrasound-guided percutaneous fine-needle aspiration of solid pancreatic neoplasms: 10-year experience with more than 2,000 cases and a review of the literature.

Authors:  Mirko D'Onofrio; Riccardo De Robertis; Emilio Barbi; Enrico Martone; Erminia Manfrin; Stefano Gobbo; Gino Puntel; Franco Bonetti; Roberto Pozzi Mucelli
Journal:  Eur Radiol       Date:  2015-09-16       Impact factor: 5.315

6.  Role of endoscopic ultrasound fine-needle aspiration evaluating adrenal gland enlargement or mass.

Authors:  Melissa Martinez; Julia LeBlanc; Mohammad Al-Haddad; Stuart Sherman; John DeWitt
Journal:  World J Nephrol       Date:  2014-08-06

Review 7.  Clinical approach to the patient with a solid pancreatic mass.

Authors:  Reinhold Függer; Odo Gangl; Uwe Fröschl
Journal:  Wien Med Wochenschr       Date:  2014-02-28

Review 8.  Diagnostic endoscopic ultrasonography: assessment of safety and prevention of complications.

Authors:  Christian Jenssen; Maria Victoria Alvarez-Sánchez; Bertrand Napoléon; Siegbert Faiss
Journal:  World J Gastroenterol       Date:  2012-09-14       Impact factor: 5.742

9.  A triple approach for diagnostic assessment of endoscopic ultrasound-guided fine needle aspiration in pancreatic solid masses and lymph nodes.

Authors:  Yun Nah Lee; Jong Ho Moon; Hee Kyung Kim; Hyun Jong Choi; Seoung Ho Lee; Moon Han Choi; Dong Choon Kim; Tae Hoon Lee; Sang-Woo Cha; Young Deok Cho; Sang-Heum Park
Journal:  Dig Dis Sci       Date:  2014-04-16       Impact factor: 3.199

10.  Optimizing Diagnostic Yield for EUS-Guided Sampling of Solid Pancreatic Lesions: A Technical Review.

Authors:  Brian R Weston; Manoop S Bhutani
Journal:  Gastroenterol Hepatol (N Y)       Date:  2013-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.