Literature DB >> 20426064

Statistically deformable 2D/3D registration for accurate determination of post-operative cup orientation from single standard X-ray radiograph.

Guoyan Zheng1.   

Abstract

The widely used procedure of evaluation of cup orientation following total hip arthroplasty using single standard anteroposterior (AP) radiograph is known inaccurate, largely due to the wide variability in individual pelvic orientation relative to X-ray plate. 2D/3D rigid image registration methods have been introduced for an accurate determination of the post-operative cup alignment with respect to an anatomical reference extracted from the CT data. Although encouraging results have been reported, their extensive usage in clinical routine is still limited. This may be explained by their requirement of a CAD model of the prosthesis, which is often difficult to be organized from the manufacturer due to the proprietary issue, and by their requirement of a pre-operative CT scan, which is not available for most retrospective studies. To address these issues, we developed and validated a statistically deformable 2D/3D registration approach for accurate determination of post-operative cup orientation. No CAD model and pre-operative CT data is required any more. Quantitative and qualitative results evaluated on cadaveric and clinical datasets are given, which indicate the validity of the approach.

Entities:  

Mesh:

Year:  2009        PMID: 20426064     DOI: 10.1007/978-3-642-04268-3_101

Source DB:  PubMed          Journal:  Med Image Comput Comput Assist Interv


  6 in total

1.  Scaled, patient-specific 3D vertebral model reconstruction based on 2D lateral fluoroscopy.

Authors:  Guoyan Zheng; Lutz-P Nolte; Stephen J Ferguson
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-07-20       Impact factor: 2.924

2.  Assessing the accuracy factors in the determination of postoperative acetabular cup orientation using hybrid 2D-3D registration.

Authors:  Guoyan Zheng
Journal:  J Digit Imaging       Date:  2009-07-21       Impact factor: 4.056

3.  Computer assisted determination of acetabular cup orientation using 2D-3D image registration.

Authors:  Guoyan Zheng; Xuan Zhang
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-02-24       Impact factor: 2.924

4.  Plan in 2-D, execute in 3-D: an augmented reality solution for cup placement in total hip arthroplasty.

Authors:  Javad Fotouhi; Clayton P Alexander; Mathias Unberath; Giacomo Taylor; Sing Chun Lee; Bernhard Fuerst; Alex Johnson; Greg Osgood; Russell H Taylor; Harpal Khanuja; Mehran Armand; Nassir Navab
Journal:  J Med Imaging (Bellingham)       Date:  2018-01-04

5.  Robustness and accuracy of feature-based single image 2-D-3-D registration without correspondences for image-guided intervention.

Authors:  Mehran Armand; Yoshito Otake; Paul Y S Cheung; Russell H Taylor
Journal:  IEEE Trans Biomed Eng       Date:  2013-08-15       Impact factor: 4.538

6.  Validation of a statistical shape model-based 2D/3D reconstruction method for determination of cup orientation after THA.

Authors:  G Zheng; J von Recum; L-P Nolte; P A Grützner; S D Steppacher; J Franke
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-07-27       Impact factor: 2.924

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.