Literature DB >> 20416068

Comparison of haematological parameters determined by the Sysmex KX - 2IN automated haematology analyzer and the manual counts.

Samuel O Ike1, Thomas Nubila, Ernest O Ukaejiofo, Imelda N Nubila, Elvis N Shu, Ifeyinwa Ezema.   

Abstract

BACKGROUND: This study was designed to determine the correlation between heamatological parameters by Sysmex KX-21N automated hematology analyzer with the manual methods.
METHOD: Sixty (60) subjects were randomly selected from both apparently healthy subjects and those who have different blood disorders from the University of Teaching Hospital (UNTH), Ituku-Ozalla, Enugu, Enugu State, Nigeria. Three (3)mls of venous blood sample was collected aseptically from each subject into tri-potassium ethylenediamine tetra-acetic acid (K3EDTA) for the analysis of haematological parameters using the automated and the manual methods.
RESULTS: The blood film report by the manual method showed that 50% of the subjects were normocytic-normochromic while the other 50% revealed different abnormal blood pictures. Also, there were statistically significant differences (p < 0.05) in mean cell hemoglobin concentrations (MCHC) between the two methods. Similarly, the mean (S.E) values of hemoglobin, packed cell volume, platelet and total white cell counts demonstrated statistically significant difference (p < 0.001) and correlated positively when both methods were compared.
CONCLUSION: From the present study, it can be concluded that the automated hematology analyzer readings correlated well with readings by the standard manual method, although the latter method gave additional diagnostic information on the blood pictures. While patients' care and laboratory operations could be optimized by using manual microscopic examination as a reflective substitute for automated methods, usage of automated method would ease our workload and save time for patients.

Entities:  

Year:  2010        PMID: 20416068      PMCID: PMC2873444          DOI: 10.1186/1472-6890-10-3

Source DB:  PubMed          Journal:  BMC Clin Pathol        ISSN: 1472-6890


  8 in total

1.  Quality control in a manual and an automated leukocyte differential count.

Authors:  T Takubo; N Tatsumi
Journal:  Southeast Asian J Trop Med Public Health       Date:  1999       Impact factor: 0.267

2.  Elimination of instrument-driven reflex manual differential leukocyte counts. Optimization of manual blood smear review criteria in a high-volume automated hematology laboratory.

Authors:  Kay L Lantis; R Jayne Harris; Gerald Davis; Nancy Renner; William G Finn
Journal:  Am J Clin Pathol       Date:  2003-05       Impact factor: 2.493

3.  The correlation between automated hematology and manually read smears for the determination of nucleated red blood cells in umbilical cord blood.

Authors:  Joan M McCarthy; Tammy Capullari; William N Spellacy
Journal:  J Matern Fetal Neonatal Med       Date:  2005-03

Review 4.  Spurious counts and spurious results on haematology analysers: a review. Part II: white blood cells, red blood cells, haemoglobin, red cell indices and reticulocytes.

Authors:  M Zandecki; F Genevieve; J Gerard; A Godon
Journal:  Int J Lab Hematol       Date:  2007-02       Impact factor: 2.877

5.  Laboratory productivity and the rate of manual peripheral blood smear review: a College of American Pathologists Q-Probes study of 95,141 complete blood count determinations performed in 263 institutions.

Authors:  David A Novis; Molly Walsh; David Wilkinson; Mary St Louis; Jonathon Ben-Ezra
Journal:  Arch Pathol Lab Med       Date:  2006-05       Impact factor: 5.534

6.  Haemocytometry by laser-beam optics: evaluation of the Hemac 630L.

Authors:  S M Lewis; S A Bentley
Journal:  J Clin Pathol       Date:  1977-01       Impact factor: 3.411

7.  Detection of abnormal cells in white cell differentials: comparison of the HEMATRAK automated system with manual methods.

Authors:  W A Rock; J B Miale; W D Johnson
Journal:  Am J Clin Pathol       Date:  1984-02       Impact factor: 2.493

Review 8.  Peripheral blood film review. The demise of the eyecount leukocyte differential.

Authors:  Robert V Pierre
Journal:  Clin Lab Med       Date:  2002-03       Impact factor: 1.935

  8 in total
  5 in total

1.  Efficacy of polysaccharide from Alcaligenes xylosoxidans MSA3 administration as protection against γ-radiation in female rats.

Authors:  Amal I Hassan; Mona A M Ghoneim; Manal G Mahmoud; Mohsen M S Asker; Saher S Mohamed
Journal:  J Radiat Res       Date:  2015-12-28       Impact factor: 2.724

2.  Methanol extracts of Basella alba leaves alleviate stress in rats.

Authors:  Olubayode Bamidele; Nkiruka Chisom Okeke; Temitope Gabriel Adedeji; Lawrence Dayo Adedayo; Akinjide Moses Akinnuga
Journal:  Chin Herb Med       Date:  2020-03-05

3.  Use of Middleware Data to Dissect and Optimize Hematology Autoverification.

Authors:  Rachel D Starks; Anna E Merrill; Scott R Davis; Dena R Voss; Pamela J Goldsmith; Bonnie S Brown; Jeff Kulhavy; Matthew D Krasowski
Journal:  J Pathol Inform       Date:  2021-04-07

4.  Lycopene improves on basic hematological and immunological parameters in diabetes mellitus.

Authors:  Ejike Daniel Eze; Adam Moyosore Afodun; Josephine Kasolo; Keneth Iceland Kasozi
Journal:  BMC Res Notes       Date:  2019-12-12

5.  Heterogeneity in Hematological Parameters of High and Low Altitude Tibetan Populations.

Authors:  Nipa Basak; Tsering Norboo; Mohammed S Mustak; Kumarasamy Thangaraj
Journal:  J Blood Med       Date:  2021-05-17
  5 in total