Spurious counts and spurious results on haematology analysers: a review. Part II: white blood cells, red blood cells, haemoglobin, red cell indices and reticulocytes.

M Zandecki1, F Genevieve, J Gerard, A Godon.   

Abstract

Haematology analysers provide quick and accurate results in most situations. However, spurious results, related either to platelets (part I of this report) or to other parameters from the cell blood count (CBC) may be observed in several instances. Spuriously low white blood cell (WBC) counts may be observed because of agglutination in the presence of ethylenediamine tetra-acetic acid (EDTA). Cryoglobulins, lipids, insufficiently lysed red blood cells (RBC), erythroblasts and platelet aggregates are common situations increasing WBC counts. In most of these instances flagging and/or an abnormal WBC differential scattergram will alert the operator. Several situations lead to abnormal haemoglobin measurement or to abnormal RBC count, including lipids, agglutinins, cryoglobulins and elevated WBC counts. Mean (red) cell volume (MCV) may be also subject to spurious determination, because of agglutinins, excess of glucose or salts and technological considerations. In turn, abnormality related to one measured parameter will lead to abnormal calculated RBC indices: mean cell haemoglobin content (MCHC) is certainly the most important RBC indices to consider, as it is as important as flags generated by the haematology analysers (HA) in alerting the user to a spurious result. In many circumstances, several of the measured parameters from CBC may be altered, and the discovery of a spurious change on one parameter frequently means that the validity of other parameters should be considered. Sensitive flags now allow the identification of several spurious counts, but only the most sophisticated HA have optimal flagging and more simple HA, especially those without a WBC differential scattergram, do not possess the same sensitivity for detecting anomalous results. Reticulocytes are integrated now into the CBC in many HA, and several situations may lead to abnormal counts.

Entities:  

Mesh:

Year:  2007        PMID: 17224005     DOI: 10.1111/j.1365-2257.2006.00871.x

Source DB:  PubMed          Journal:  Int J Lab Hematol        ISSN: 1751-5521            Impact factor:   2.877


  25 in total

1.  Influence of a light meal on routine haematological tests.

Authors:  Giuseppe Lippi; Gabriel Lima-Oliveira; Gian Luca Salvagno; Martina Montagnana; Matteo Gelati; Geraldo Picheth; Alberto José Duarte; Massimo Franchini; Gian Cesare Guidi
Journal:  Blood Transfus       Date:  2010-04       Impact factor: 3.443

2.  Spurious Leukocyte Counts and an Abnormal Histogram Pattern Due to Fibrin Clumps.

Authors:  Ashish Kumar; Ritesh Goswami; Markas Masih; Naveen Kakkar
Journal:  Indian J Hematol Blood Transfus       Date:  2018-08-06       Impact factor: 0.900

3.  Unusual underlying disorder for pulmonary embolism: Cold agglutinin disease.

Authors:  Shumpei Onishi; Toshihisa Ichiba; Natsuki Miyoshi; Takeshi Nagata; Hiroshi Naito
Journal:  J Cardiol Cases       Date:  2016-11-18

4.  Comparison of haematological parameters determined by the Sysmex KX - 2IN automated haematology analyzer and the manual counts.

Authors:  Samuel O Ike; Thomas Nubila; Ernest O Ukaejiofo; Imelda N Nubila; Elvis N Shu; Ifeyinwa Ezema
Journal:  BMC Clin Pathol       Date:  2010-04-23

5.  Mucopolysaccharidosis type VI in a juvenile miniature schnauzer dog with concurrent hypertriglyceridemia, necrotizing pancreatitis, and diabetic ketoacidosis.

Authors:  Mayrim L Pérez; Heather A Kridel; Alex Gallagher; Barbara J Sheppard; Shona Reese; Hirotaka Kondo; Rick Alleman; Urs Giger
Journal:  Can Vet J       Date:  2015-03       Impact factor: 1.008

6.  Correction of pseudoreticulocytosis in leukocytosis samples using the Sysmex XE-2100 analyzer depends on the type and number of white blood cells.

Authors:  Ahhyun Kim; Joonhong Park; Myungshin Kim; Jihyang Lim; Eun-Jee Oh; Yonggoo Kim; Yeon-Joon Park; Kyungja Han
Journal:  Ann Lab Med       Date:  2012-10-17       Impact factor: 3.464

7.  Human erythrocyte fragmentation during ex-vivo pig organ perfusion.

Authors:  Zahra A Habibabady; Selin Sendil; Felix Ellett; Franziska Pollok; Gabriela F Elias; Beth M French; Wenji Sun; Gheorghe Braileanu; Lars Burdorf; Daniel Irimia; Richard N Pierson; Agnes M Azimzadeh
Journal:  Xenotransplantation       Date:  2022-02-02       Impact factor: 3.907

8.  Comparison of venous and capillary differential leukocyte counts using a standard hematology analyzer and a novel microfluidic impedance cytometer.

Authors:  Veronica S Hollis; Judith A Holloway; Scott Harris; Daniel Spencer; Cees van Berkel; Hywel Morgan
Journal:  PLoS One       Date:  2012-09-20       Impact factor: 3.240

9.  Multiple thromboembolism with multiple causes in a 69-year-old woman: a case report.

Authors:  Luigi Iuliano; Maria Misuraca; Alessandro Varroni; Massimo Raponi; Marco Massucci; Alessandro Pagnanelli; Giuseppe Cimino; Giovanni Bertoletti
Journal:  J Med Case Rep       Date:  2011-05-14

10.  Convenience of Hgb-O detected by optical method in XN-series hematology analyzers in evaluating hemoglobin concentration in samples with chylous turbidity.

Authors:  Yu Aruga; Chiaki Ikeda; Arisa Hanai; Sakiko Yoshimura; Momoko Kito; Satoe Miyaki; Misato Tsubokura; Yuka Yasuno; Chiaki Hayashi; Motoi Miyakoshi; Takahiro Nishino; Kimihiko Kawamura; Hiromichi Matsushita
Journal:  Sci Rep       Date:  2021-07-22       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.