Literature DB >> 20406256

On repeated corneal applanation with the Goldmann and two non-contact tonometers.

Turki M Almubrad1, Kelechi C Ogbuehi.   

Abstract

BACKGROUND: Several authors believe it is necessary to randomise the order in which contact and non-contact tonometers are used in comparison studies. This study was carried out to investigate the effect of repeated applanation on the measured intraocular pressure.
METHODS: One set of measurements per session was made on each of three sessions (one session per day) with the Goldmann and two non-contact tonometers (Topcon CT80 and Keeler Pulsair EasyEye), in a pre-determined order, on one randomly selected eye of 120 subjects randomised to one of two groups. For session one, only the non-contact tonometers were used to assess the intraocular pressure of both groups. For session two, either non-contact or Goldmann tonometry was performed first and this order was reversed for session 3. Average intraocular pressures were compared between sessions to determine the presence or absence of effects on the intraocular pressure caused by prior repeated applanation with the Goldmann or either one (or both) of the non-contact tonometers.
RESULTS: Prior applanation with a non-contact tonometer did not cause a significant (p > 0.05) reduction of the mean pressure measured with either non-contact tonometer. The mean pressure was slightly but significantly (p < 0.05) reduced (for both non-contact tonometers in both subject groups) when non-contact tonometry was performed after Goldmann tonometry. There was no significant difference (p > 0.05) between the pressures measured with the Goldmann tonometer prior to and subsequent to non-contact tonometry, in both subject groups.
CONCLUSION: A small but statistically significant reduction in the intraocular pressure was found following applanation with the Goldmann tonometer but not with either one of two non-contact tonometers.

Entities:  

Mesh:

Year:  2010        PMID: 20406256     DOI: 10.1111/j.1444-0938.2010.00453.x

Source DB:  PubMed          Journal:  Clin Exp Optom        ISSN: 0816-4622            Impact factor:   2.742


  10 in total

1.  Repeatability of intra-ocular pressure and central corneal thickness measurements provided by a non-contact method of tonometry and pachymetry.

Authors:  Domenico Schiano Lomoriello; Marco Lombardo; Laura Tranchina; Francesco Oddone; Sebastiano Serrao; Pietro Ducoli
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-10-28       Impact factor: 3.117

2.  Long-term intraocular pressure changes after combined phacoemulsification, intraocular lens implantation, and vitrectomy.

Authors:  Yuya Ki-I; Takehiro Yamashita; Akinori Uemura; Taiji Sakamoto
Journal:  Jpn J Ophthalmol       Date:  2012-10-27       Impact factor: 2.447

3.  [Evaluation of the self-tonometer Icare ONE in comparison to Goldmann applanation tonometry].

Authors:  V Witte; Ä Glass; R Beck; R Guthoff
Journal:  Ophthalmologe       Date:  2012-10       Impact factor: 1.059

4.  Performance of the PT100 noncontact tonometer in healthy eyes.

Authors:  Turki M AlMubrad
Journal:  Clin Ophthalmol       Date:  2011-05-19

5.  Intraocular Pressure Rise in Subjects with and without Glaucoma during Four Common Yoga Positions.

Authors:  Jessica V Jasien; Jost B Jonas; C Gustavo de Moraes; Robert Ritch
Journal:  PLoS One       Date:  2015-12-23       Impact factor: 3.240

6.  Comparison of intraocular pressure as measured by three different non-contact tonometers and goldmann applanation tonometer for non-glaucomatous subjects.

Authors:  Seung Pil Bang; Chong Eun Lee; Yu Cheol Kim
Journal:  BMC Ophthalmol       Date:  2017-11-02       Impact factor: 2.209

7.  Tonographic Effect of Ocular Response Analyzer in Comparison to Goldmann Applanation Tonometry.

Authors:  Martin Zimmermann; Susanne Pitz; Irene Schmidtmann; Norbert Pfeiffer; Joanna Wasielica-Poslednik
Journal:  PLoS One       Date:  2017-01-09       Impact factor: 3.240

8.  Intraocular pressure and cerebral oxygenation during prolonged headward acceleration.

Authors:  Ola Eiken; Michail E Keramidas; Nigel A S Taylor; Mikael Grönkvist
Journal:  Eur J Appl Physiol       Date:  2016-11-11       Impact factor: 3.078

9.  Effects of different sleeping positions on intraocular pressure in secondary open-angle glaucoma and glaucoma suspect patients.

Authors:  Jeffrey H Sedgewick; Justin A Sedgewick; Brandon A Sedgewick; Berk Ekmekci
Journal:  Clin Ophthalmol       Date:  2018-08-01

10.  Comparison of the corrected intraocular pressure by tonopachy with that of Goldmann applanation tonometry in normal and glaucomatous patients.

Authors:  Girish Velis; Srinivasan Kavitha; Nazlee Zebardast; Sabyasachi Sengupta; Rengaraj Venkatesh
Journal:  Indian J Ophthalmol       Date:  2020-04       Impact factor: 1.848