Literature DB >> 20404720

A mechanical simulator of cardiac wall kinematics.

Elena Cutrì1, Paola Bagnoli, Emanuela Marcelli, Federico Biondi, Laura Cercenelli, Maria Laura Costantino, Gianni Plicchi, Roberto Fumero.   

Abstract

Aim of this study is to develop a mechanical simulator (MS) reproducing cardiac wall kinematics [i.e., radial (R), longitudinal (L) and rotational (RT) motions] to test piezoelectric gyroscopic sensors (GS) that are able to measure cardiac torsion that has proved to be a sensitive index of cardiac performance. The MS consists of three brushless motors controlled by a dedicated software either separately or simultaneously reproducing the three main cardiac wall movements (R, L, RT) obtained by implementing different physiologic or pathologic velocity profiles derived from in vivo data. GS accuracy (max % error) was experimentally tested by connecting it to the MS driven in velocity in different working conditions [i.e., cardiac period (515-1030 ms), RT angle (4-16 degrees), GS axis inclination (0-90 degrees) with respect to the cardiac rotation axis]. The MS reproduced the tested velocity profiles well. The GS showed high accuracy in measuring both physiologic and pathologic RT velocity profiles, whereas they proved insensitive to R and L motions. GS axis inclination influenced measurements; however, it was possible to correct this taking the inclination angle cosine into account. The MS proved to be a useful tool to study cardiac wall kinematics and test GS reliability with a view to in vivo application.

Entities:  

Mesh:

Year:  2010        PMID: 20404720     DOI: 10.1097/MAT.0b013e3181d7db0c

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

1.  4 Dimensional XStrain speckle tracking echocardiography: comprehensive evaluation of left ventricular strain and twist parameters in healthy Indian adults during COVID-19 pandemic.

Authors:  Akhil Mehrotra; Shubham Kacker; Mohammad Shadab; Naveen Chandra; Alok Kumar Singh
Journal:  Am J Cardiovasc Dis       Date:  2022-08-15

2.  An Implantable Sensorized Lead for Continuous Monitoring of Cardiac Apex Rotation.

Authors:  Emanuela Marcelli; Laura Cercenelli
Journal:  Sensors (Basel)       Date:  2018-11-30       Impact factor: 3.576

3.  Comprehensive assessment of left ventricular myocardial function by two-dimensional speckle-tracking echocardiography.

Authors:  Vicente Mora; Ildefonso Roldán; Elena Romero; Diana Romero; Javier Bertolín; Natalia Ugalde; Carmen Pérez-Olivares; Melisa Rodriguez-Israel; Jana Pérez-Gozalbo; Jorge A Lowenstein
Journal:  Cardiovasc Ultrasound       Date:  2018-09-18       Impact factor: 2.062

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.