Simulation-based evaluation and optimization of a new CdZnTe gamma-camera architecture (HiSens).

Charlotte Robert1, Guillaume Montémont, Véronique Rebuffel, Irène Buvat, Lucie Guérin, Loïck Verger.   

Abstract

A new gamma-camera architecture named HiSens is presented and evaluated. It consists of a parallel hole collimator, a pixelated CdZnTe (CZT) detector associated with specific electronics for 3D localization and dedicated reconstruction algorithms. To gain in efficiency, a high aperture collimator is used. The spatial resolution is preserved thanks to accurate 3D localization of the interactions inside the detector based on a fine sampling of the CZT detector and on the depth of interaction information. The performance of this architecture is characterized using Monte Carlo simulations in both planar and tomographic modes. Detective quantum efficiency (DQE) computations are then used to optimize the collimator aperture. In planar mode, the simulations show that the fine CZT detector pixelization increases the system sensitivity by 2 compared to a standard Anger camera without loss in spatial resolution. These results are then validated against experimental data. In SPECT, Monte Carlo simulations confirm the merits of the HiSens architecture observed in planar imaging.

Mesh:

Substances:

Year:  2010        PMID: 20400808     DOI: 10.1088/0031-9155/55/9/019

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

Review 1.  Nuclear imaging of the breast: translating achievements in instrumentation into clinical use.

Authors:  Carrie B Hruska; Michael K O'Connor
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

2.  Molecular breast imaging: an emerging modality for breast cancer screening.

Authors:  Michael K O'Connor
Journal:  Breast Cancer Manag       Date:  2015-01-01

3.  An energy-optimized collimator design for a CZT-based SPECT camera.

Authors:  Fenghua Weng; Srijeeta Bagchi; Yunlong Zan; Qiu Huang; Youngho Seo
Journal:  Nucl Instrum Methods Phys Res A       Date:  2016-01-11       Impact factor: 1.455

4.  Molecular Breast Imaging using Synthetic Projections from High-Purity Germanium Detectors: A Simulation Study.

Authors:  Desmond Campbell; Todd Peterson
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2017-07-11

5.  Evaluation of a variable-aperture full-ring SPECT system using large-area pixelated CZT modules: A simulation study for brain SPECT applications.

Authors:  Yoonsuk Huh; Jaewon Yang; Odera U Dim; Yonggang Cui; Weijie Tao; Qiu Huang; Grant T Gullberg; Youngho Seo
Journal:  Med Phys       Date:  2021-03-30       Impact factor: 4.071

6.  Technical Note: Nuclear imaging with an x-ray flat panel detector: A proof-of-concept study.

Authors:  Martijn M A Dietze; Wilco J C Koppert; Rob van Rooij; Hugo W A M de Jong
Journal:  Med Phys       Date:  2020-05-08       Impact factor: 4.071

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.