Reduction of motion artifacts in magnetic resonance imaging of the neck and cervical spine by long-term averaging.

J Seitz1, M Strotzer, M Völk, P Held, B Djavidani, W R Nitz, S Feuerbach.   

Abstract

RATIONALE AND
OBJECTIVES: We performed a prospective comparison of T1-weighted turbo spin-echo (TSE) imaging with standard averaging and with the long-term averaging method (LOTA), comparing the effects on signal-to-artifact noise ratio (S/aN) and motion artifacts.
METHODS: In 30 consecutive patients undergoing imaging of the neck or cervical spine, a transverse T1-weighted TSE sequence was applied with and without LOTA by using identical sequence parameters. Quantitative image analysis was done by calculating S/Ns in the phase-encoding direction (S/aN). Visual image analysis was performed by four independent, masked readers using a standardized score sheet for anatomic and pathological findings.
RESULTS: The LOTA sequence yielded significantly superior S/aN values compared with the standard averaging sequence. In the subjective evaluation, the LOTA sequence showed significantly fewer motion artifacts and better visualization of normal anatomy of the neck, cervical spine, and spinal cord, as well as of the pathological findings.
CONCLUSIONS: LOTA is a valuable method for increasing S/aN in magnetic resonance imaging of the neck and cervical spine. It reduces motion artifacts and increases the conspicuity of pathology without increasing acquisition time. No additional hardware is needed, and this technique can be combined with other artifact-reducing methods.

Entities:  

Mesh:

Year:  2000        PMID: 10853613     DOI: 10.1097/00004424-200006000-00007

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  5 in total

1.  Decreased CSF-flow artefacts in T2 imaging of the cervical spine with periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER/BLADE).

Authors:  Andreas Ragoschke-Schumm; Peter Schmidt; Julia Schumm; Georg Reimann; Hans-Joachim Mentzel; Werner A Kaiser; Thomas E Mayer
Journal:  Neuroradiology       Date:  2010-04-13       Impact factor: 2.804

2.  Technical aspects of cardiac PET/MRI.

Authors:  Atsuro Masuda; Ayaka Nemoto; Yasuchika Takeishi
Journal:  J Nucl Cardiol       Date:  2018-02-21       Impact factor: 5.952

3.  BLADE in sagittal T2-weighted MR imaging of the cervical spine.

Authors:  C Fellner; C Menzel; F A Fellner; C Ginthoer; N Zorger; A Schreyer; E M Jung; S Feuerbach; T Finkenzeller
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-26       Impact factor: 3.825

4.  Objective determination of optimal number of spectral-domain optical coherence tomographic images of retina to average.

Authors:  Makoto Shirasawa; Taiji Sakamoto; Hiroto Terasaki; Takehiro Yamashita; Eisuke Uchino; Shozo Sonoda
Journal:  PLoS One       Date:  2014-10-22       Impact factor: 3.240

5.  MRI quality control for low-field MR-IGRT systems: Lessons learned.

Authors:  H Michael Gach; Austen N Curcuru; Erin J Wittland; Borna Maraghechi; Bin Cai; Sasa Mutic; Olga L Green
Journal:  J Appl Clin Med Phys       Date:  2019-09-21       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.