Literature DB >> 20381750

Accuracy and reliability of tooth and root lengths measured on cone-beam computed tomographs.

John F Sherrard1, P Emile Rossouw, Byron W Benson, Roberto Carrillo, Peter H Buschang.   

Abstract

INTRODUCTION: In this study, we evaluated the accuracy and reliability of tooth-length and root-length measurements derived from cone-beam computed tomography (CBCT) volumetric data.
METHODS: CBCT scans were made of 7 fresh porcine heads. The scans were made with an i-CAT machine (Imaging Sciences International, Hatfield, Pa) at 0.2, 0.3, and 0.4 mm voxel sizes. Two film-acquired periapical radiographs were also taken of selected incisors and premolars, 52 of which (28 premolars, 24 incisors) were included in this study. By using Dolphin imaging software (version 10.5, Dolphin Imaging Systems, Chatsworth, Calif), the CBCT scans were oriented twice for each tooth (ie, 2 trials) using the mesial, distal, labial, and lingual cementoenamel junctions as reference points. Root and tooth lengths were derived from these points and compared with actual measurements of the teeth made with digital calipers after all surrounding bone had been carefully removed.
RESULTS: CBCT tooth-length and root-length measurements were not significantly different from the actual lengths; the mean differences were less than 0.3 mm. The periapical measurements significantly (P = 0.001) underestimated root lengths (mean difference, 2.58 mm) and overestimated tooth lengths (mean difference, 2.58 mm; P = 0.056). Mean differences between the 3 CBCT voxel sizes were all less than 0.25 mm. Within-trial method errors were almost 2 times greater for the periapical radiographs than for the CBCT scans. Between-trial method errors were greatest for the 0.4-mm CBCT scans, which were within 0.1 mm of the periapical radiograph method errors. The intraclass correlations for the periapical and CBCT measurements were all above 0.995.
CONCLUSIONS: CBCT scans are at least as accurate and reliable as periapical radiographs for tooth-length and root-length determinations. Copyright 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20381750     DOI: 10.1016/j.ajodo.2009.03.040

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  44 in total

Review 1.  The current status of cone beam computed tomography imaging in orthodontics.

Authors:  S Kapila; R S Conley; W E Harrell
Journal:  Dentomaxillofac Radiol       Date:  2011-01       Impact factor: 2.419

2.  Classification of periodontal biotypes with the use of CBCT. A cross-sectional study.

Authors:  Maria Nikiforidou; Lazaros Tsalikis; Christos Angelopoulos; Georgios Menexes; Ioannis Vouros; Antonios Konstantinides
Journal:  Clin Oral Investig       Date:  2015-12-22       Impact factor: 3.573

3.  The use of cone beam computed tomography to predetermine root canal lengths in molar teeth: a comparison between two-dimensional and three-dimensional measurements.

Authors:  J P Tchorz; P J Poxleitner; S Stampf; S B M Patzelt; D Rottke; E Hellwig; M J Altenburger
Journal:  Clin Oral Investig       Date:  2013-07-30       Impact factor: 3.573

4.  Accuracy assessment of the axial images obtained from cone beam computed tomography.

Authors:  Francine Kühl Panzarella; J L C Junqueira; L B Oliveira; N S de Araújo; C Costa
Journal:  Dentomaxillofac Radiol       Date:  2011-09       Impact factor: 2.419

5.  Comparison of the influence of FOV sizes and different voxel resolutions for the assessment of periodontal defects.

Authors:  M E Kolsuz; N Bagis; K Orhan; H Avsever; K Ö Demiralp
Journal:  Dentomaxillofac Radiol       Date:  2015-04-22       Impact factor: 2.419

Review 6.  CBCT in orthodontics: assessment of treatment outcomes and indications for its use.

Authors:  S D Kapila; J M Nervina
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

7.  [Analysis of bifid mandibular canal via cone beam computed tomography].

Authors:  Guo Yi; Zhang Qiaohong; Han Xiaoqian
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2015-04

8.  Letters From Our Readers.

Authors:  Marcio Rodrigues de Almeida
Journal:  Angle Orthod       Date:  2019-01       Impact factor: 2.079

Review 9.  Impact of voxel size variation on CBCT-based diagnostic outcome in dentistry: a systematic review.

Authors:  Rubens Spin-Neto; Erik Gotfredsen; Ann Wenzel
Journal:  J Digit Imaging       Date:  2013-08       Impact factor: 4.056

10.  Cone beam CT evaluation of the presence of anatomic accessory canals in the jaws.

Authors:  M Eshak; S Brooks; N Abdel-Wahed; P C Edwards
Journal:  Dentomaxillofac Radiol       Date:  2014-02-26       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.