Literature DB >> 20378588

Indoor secondhand tobacco smoke emission levels in six Lebanese cities.

Georges Saade1, Andrew B Seidenberg, Vaughan W Rees, Zaher Otrock, Gregory N Connolly.   

Abstract

BACKGROUND: To date, Lebanon has failed to enact comprehensive clean indoor air laws despite ratification of the Framework Convention on Tobacco Control (FCTC), which calls for the protection of non-smokers from exposure to secondhand tobacco smoke (SHS). Complicating the problem of SHS exposure in Lebanon is the widespread use of the tobacco water-pipe. While most research on SHS has involved cigarette smoking as a source of emissions, other sources, including tobacco water-pipes, may be an important contributor.
METHODS: PM(2.5) concentrations (microg/m(3)) were measured in a sample of 28 public venues located in six major Lebanese cities. Active smoker density (number of smokers/100 m(3)) was calculated for both water-pipe and cigarette smokers. Venues were then categorised as having higher density of water-pipe smokers or higher density of cigarette smokers, and resultant emission levels were compared between the two groups.
RESULTS: Cigarette and water-pipe smoking was observed in 14 venues, while cigarette smoking only and water-pipe smoking only were found in 12 venues and one venue, respectively. Among all smoking-permitted venues, the mean PM(2.5) concentration was 342 microg/m(3). Venues with a higher density of water-pipe smokers (n =14) showed a similar median PM(2.5) concentration (349 microg/m(3)) compared with venues with a higher density of cigarette smokers (n =13; 241 microg/m(3); p=0.159). The mean PM(2.5) concentration in the single venue with a voluntary smoke-free policy was 6 microg/m(3).
CONCLUSIONS: Despite ratification of the FCTC in 2005, both cigarette and water-pipe smoking are commonly practised in enclosed public places throughout Lebanon, leading to unsafe levels of indoor particulate pollution. Smoke-free policies are needed in Lebanon to protect the public's health, and should apply to all forms of tobacco smoking.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20378588      PMCID: PMC2989171          DOI: 10.1136/tc.2009.030460

Source DB:  PubMed          Journal:  Tob Control        ISSN: 0964-4563            Impact factor:   7.552


Introduction

Exposure to secondhand tobacco smoke (SHS) is a major, preventable cause of premature death and disease in non-smokers.1 SHS contains over 2500 chemical constituents, of which approximately 250 are known to be toxic or carcinogenic.2 Exposure to SHS among children is a major paediatric problem and is associated with increased risk of sudden infant death syndrome, acute respiratory infections, ear problems and worsening of asthma symptoms.1 While most research on SHS has involved cigarettes as a source of emissions, other sources, including tobacco water-pipes, may be an important contributor.3 Tobacco water-pipes, also known as hookah, involve a unique design in which tobacco smoke is drawn through a water bubbler before reaching the smoker. The tobacco used in water-pipes, often known as moassel, is a highly sweetened and flavoured blend with high moisture content. The tobacco is heated by burning charcoal, and it releases a caramelised sugar or fruit-scented aroma as it is smoked.4 Water-pipe smoking is often regarded by its users as less harmful than cigarettes,5 6 possibly because of its unique design, the flavoured tobacco use and scented SHS emissions. Many of the constituents found in cigarette smoke have also been identified in water-pipe emissions.7 8 Both sources of SHS carry respirable suspended particles.3 9 10 Limited laboratory testing has suggested that particulate emissions arising from active water-pipe smoking may be comparable to or greater than cigarette emissions. Water-pipe sessions lasting 30 minutes may generate similar emission levels as a single cigarette smoked for about 10 minutes.3 The World Health Organization has established air quality guidelines (AQG)11 for particulate matter based on the scientific evidence demonstrating a link between exposure to fine particulate air pollution and adverse health outcomes including cardiopulmonary events12 and mortality.13 To protect the public's health, the current WHO guideline for PM2.5 pollution is a daily mean exposure of 25 μg/m3.11 However, fine particulate pollution levels within indoor public venues that permit smoking have been found to exceed this recommendation by severalfold.9 To address the widespread public health problem of exposure to SHS, a growing number of countries have enacted legislation prohibiting indoor smoking in public places. To encourage broader adoption of such policies, Article 8 of WHO's Framework Convention on Tobacco Control (FCTC), the world's first global public health treaty, calls for implementation of effective measures to protect all people from exposure to SHS.14 Lebanon ratified the FCTC in December of 2005; however, no restrictions on smoking in workplaces, public transit or indoor public places have yet been enacted. A comprehensive policy response to SHS exposure first requires the development of an appropriate research base to document the nature and extent of the problem. At the current time, only one known investigation has monitored air quality in environments in which smoking occurs in Lebanon.9 However, the number of Lebanese venues sampled in this investigation was relatively small (n=9) and no information on the number of cigarette and water-pipe smokers in these venues was reported. Further, data demonstrating the contribution of water-pipe smoking, a favoured form of tobacco use in Lebanon, to SHS smoke emissions are urgently needed. The present study aimed to document the prevalence of indoor smoking—both cigarette and water-pipe—and corresponding indoor air quality in Lebanon. A secondary aim was to compare air quality between venues where mostly cigarette smoking occurred versus venues with mostly water-pipe smoking. Because water-pipe and cigarette emissions cannot be measured separately in venues where both types of smoking occur, venues were categorised as having either higher water-pipe or higher cigarette smoker densities, and emissions levels among these two venue types were compared.

Materials and methods

Between June and September 2008, indoor air quality was measured inside 28 enclosed public places in the Lebanese cities of Antelias, Batroun, Beirut, Koura, Saida and Tripoli. The six cities were selected using a purposive strategy, intended to reflect geographical and economic diversity: Antelias is located in the Mount Lebanon region; the northern city of Batroun is known for its entertainment and night life; the central coastal city of Beirut is the nation's capital and largest city; Koura is an intellectual district in the north; Saida is the nation's third largest city and is located in the south; the northern city of Tripoli is the country's second largest city. Study venues were also purposively selected, and included a range of hospitality venues, including cafes, restaurants, pubs and a night club. Hospital cafeterias and a shopping mall were also included to diversify the type of venues sampled. Within each city, efforts were made to visit hospitality venues in at least two popular entertainment districts. For logistical reasons, venues were selected on the basis of convenience by the research staff while attempting nevertheless to recruit venues that were representative in terms of size, location and clientele, for each region. To ensure the sampling of at least one smoke-free venue, a cafe with a known voluntary smoke-free policy was included. The TSI SidePak AM510 Personal Aerosol Monitor (TSI, Inc, St Paul, MN, USA) was used to sample and record the levels of respirable suspended particles. The Sidepak uses a sampling pump to draw air into the device and the concentration of particulate matter is determined using light scattering technology.9 A 2.5-μm impactor was employed to measure the levels of particulate matter with a mass-median aerodynamic diameter ≤2.5 μm (PM2.5). A Sidepak calibration factor of 0.32 was used. The data logging interval was set to 1 minute and the device was turned on and off inside each venue to prevent contamination with outside air. The air monitoring device was positioned in a central location inside each venue and air within occupants' normal breathing area was sampled. Data were collected unobtrusively to ensure natural behaviour of patrons and employees. The number of cigarette and water-pipe smokers was also counted upon entry into each venue and each subsequent 15-minute interval. A minimum of 15 minutes was spent monitoring air quality in each venue, and at least two such counts were performed to calculate mean number of smokers (cigarette and water-pipe). The internal volume of each venue was measured using an AEG UM 15L Sonic Measure (AEG Elektrowerkzeuge, Winnenden, Germany).

Results

Both cigarette smoking and water-pipe smoking were present in 14 of the venues, in contrast to 12 venues in which cigarette smoking only occurred. Water-pipe smoking alone was found in a single venue. Smoking (either cigarettes or water-pipe) thus was observed in all venues except the one cafe with a known voluntary smoke-free policy. The number of cigarette smokers in each of the smoking-permitted venues ranged from 0 to 175, while the number of water-pipe smokers ranged from 0 to 72. Across all smoking-permitted venues, the median number of cigarette smokers was 3.0 and water-pipe smokers was 2.3. The active water-pipe and cigarette smoker densities (ASDWP and ASDCIG, respectively) were calculated for each venue by dividing the mean number of water-pipe or cigarette smokers by venue volume (100 m3). Mean PM2.5 levels among all smoking-permitted venues ranged from 28 μg/m3 to 1324 μg/m3 and the overall mean for these venues was 342 μg/m3. In the only smoke-free venue, the mean PM2.5 concentration was 6 μg/m3, which was the lowest mean PM2.5 level observed for all venues visited. Four of the venues sampled (1, 2, 3 and 21) hosted festive Ramadan events within enclosed tents. Smoking was present in each and high levels of air pollution were found. The mean PM2.5 level for these four venues was 538 μg/m3. ASDTOTAL was calculated by dividing the total number of smokers (water-pipe plus cigarette smokers) by venue volume (100 m3). Among all venues sampled, ASDTOTAL was positively correlated with PM2.5 concentration (Spearman's r=0.467; p=0.012). The smoking-permitted venues were then classified into two groups: those with a higher density of water-pipe smokers (n=14) and those with a higher density of cigarette smokers (n=13). Because it is impossible to separately measure the emissions from water-pipes and cigarettes in venues with both sources of pollution, the strategy to compare venues on the basis of smoker density—cigarette versus water-pipe—is a practical approach to better understand how each source of SHS contributes to a venue's overall air quality. Table 1 presents PM2.5 levels for each venue in decreasing order, separated by venues with greater water-pipe smoking density, cigarette smoking density and no observed smoking. Median PM2.5 levels were found to be greater for venues with higher ASDWP (349 μg/m3) compared with those with higher ASDCIG (241 μg/m3), but this difference was not statistically significant (two-sample Wilcoxon rank sum test z=−1.407; p=0.159). Figure 1 shows PM2.5 concentrations for venues with greater water-pipe and cigarette smoker densities, with the median for each group represented in a horizontal line. Also detailed are the relative proportions of water-pipe and cigarette smokers observed in each venue.
Table 1

Summary statistics for each venue visited

Venue NoPM2.5 levels (μg/m3)ASDWP (No of smokers/100 m3)ASDCIG (No of smokers/100 m3)Volume (m3)Venue typeCity
Venues with greater ASDWP
17234.250.651683Cafe-restaurantAntelias
26480.980.161290CafeTripoli
35403.031.132380Cafe-restaurantAntelias
45232.141.44749RestaurantAntelias
55051.630.13796Cafe-restaurantAntelias
64775.801.79112CafeTripoli
73552.900.00396CafeTripoli
83421.750.20646Cafe-restaurantBeirut
93042.531.4391CafeSaida
102601.760.33598Cafe-restaurantBeirut
112332.671.3375CafeSaida
122283.460.58433Cafe-restaurantAntelias
13780.550.281125Cafe-restaurantBeirut
14391.740.98287CafeSaida
Venues with greater ASDCIG
1513240.0019.80884Night clubBatroun
165060.001.58557Pub-restaurantBeirut
174410.002.38231Hospital cafeteriaKoura
183661.802.73183CafeSaida
193160.001.40358Cafe-restaurantBeirut
202520.003.11106Cafe-restaurantBeirut
212410.000.80287Cafe-restaurantSaida
221810.004.19253RestaurantBeirut
231010.001.95128Hospital cafeteriaKoura
24930.003.85273Pub-restaurantBatroun
25730.002.0758RestaurantBeirut
26560.000.271125Cafe-restaurantBeirut
27280.000.103888Shopping mallBeirut
Venues with no observed smoking
2860.000.00120CafeBeirut

ASDCIG, active cigarette smoker density; ASDWP, active water-pipe smoker density.

Figure 1

Mean PM2.5 levels and relative proportions of water-pipe and cigarette smokers observed for venues with greater water-pipe and cigarette smoker densities.

Summary statistics for each venue visited ASDCIG, active cigarette smoker density; ASDWP, active water-pipe smoker density. Mean PM2.5 levels and relative proportions of water-pipe and cigarette smokers observed for venues with greater water-pipe and cigarette smoker densities.

Discussion

The present study assessed indoor air quality among a sample of enclosed public places in multiple cities in Lebanon. Despite ratification of the FCTC by the Lebanese government in December 2005, which calls for the adoption of measures to protect the public from ‘exposure to tobacco smoke in indoor workplaces’14 (eg, bars and restaurants), the absence of clean indoor air laws has allowed the continuation of widespread indoor smoking. Cigarette and/or water-pipe use was observed in 27 of the 28 venues visited. Among these venues the mean PM2.5 concentration was 342 μg/m3. In contrast, the mean PM2.5 concentration in the one smoke-free venue was 6 μg/m3. To put the measured PM2.5 levels into perspective, a comparison can be made to the WHO's air quality guideline.11 According to this guideline, exposure to PM2.5 pollution should not exceed a daily average of 25 μg/m3 (see figure 1). Among the 27 smoking-permitted venues, the overall mean PM2.5 concentration far exceeded this value, with the most polluted venue having a mean concentration of 1324 μg/m3. Owing to such elevated levels, individuals working in many of these venues, and thus exposed for prolonged periods, multiple times per week, are likely to be at risk of exposure to unsafe PM2.5 levels, as well as exposure to multiple toxic smoke constituents, including a number of known carcinogens.2 The elevated levels of indoor air pollution are consistent with measurements taken within smoking-permitted venues in other countries and underscore the urgent need to implement smoke-free policies to protect employees and patrons. For instance, measurements taken in Romania, Syria and Tunisia, had geometric mean levels of 386 μg/m3, 372 μg/m3 and 328 μg/m3, respectively.9 In jurisdictions that have enacted smoke-free legislation, significant declines in PM2.5 pollution15–17 and related health risks and outcomes18–20 have resulted after implementation. A small, but growing, body of research has addressed water-pipe use and the resulting emissions, but there is still relatively little research documenting the effect of water-pipe use on indoor air quality in the field. The present study is among the first to report on indoor air quality in venues where water-pipe smoking occurs. Indoor water-pipe use was observed in approximately half of the venues visited. Water-pipe smoking has the potential to generate high levels of PM2.5 emissions. In the one venue where only water-pipe smoking was observed, the mean PM2.5 concentration was 355 μg/m3. Moreover, venues with greater density of water-pipe smokers had (non-significantly) higher levels of particulate pollution, compared to those with a greater density of cigarette smokers. The present data suggest that water-pipe smoking is a major contributor to indoor air pollution, and may contribute similar levels of PM2.5 as cigarette smoking in public venues. Water-pipe smoking produces high levels of carbon monoxide, which arise from the burning coal heat source.7 The measurement of carbon monoxide in addition to particulate matter would provide important additional information about air quality in venues in which water-pipes are used. Despite the potentially high SHS levels arising from indoor water-pipe use, there is no information on whether SHS arising from water-pipes is perceived as harmful by those exposed. Research has shown that water-pipe smoking is regarded as less harmful than cigarette smoking.5 6 Further research is needed to establish whether SHS emissions of water-pipes also are perceived as less harmful than cigarettes. The holiday of Ramadan occurred during the timeframe of the current investigation. During this holy month it is customary for many families to eat in the evenings in large enclosed ‘Ramadan tents’, where water-pipe smoking is common. Particulate pollution levels averaged 538 μg/m3 within the four venues hosting Ramadan events. Such unsafe levels are of particular concern given the presence of children in these venues. Smoking was also observed in other types of venues commonly frequented by children, such as hospital cafeterias, restaurants and cafes. Limitations of the study design pose problems in generalising these findings to all venues within the six cities visited. These include the convenience selection of venues, seasonal bias and number of venues visited. Moreover, this study presents limitations in distinguishing between cigarette and water-pipe emissions and isolating their relative contributions to observed PM2.5 levels. A direct comparison between water-pipe and cigarette PM2.5 emissions would require separate measurements of each emission source while controlling for internal venue volume, air exchange rate and other factors influencing the aerodynamic behaviour of fine particles including smoker density and smoker puffing behaviour. PM2.5 may also arise from other sources such as ambient air pollution and cooking. Future research might partially resolve this problem by monitoring air quality in cigarette-only and water-pipe-only venues, as well as dual-use venues. However, this may be difficult to achieve (at least in Lebanon) because of the high co-occurrence of cigarette and water-pipe smoking. Further, making observations during the month of Ramadan could distort findings, as observance of the Ramadan holiday calls for abstinence from smoking until sundown, thus potentially diminishing SHS levels during daylight hours and increasing them at night. However, unsafe SHS levels were observed in most venues, covering both day and night-time sampling, and further research may confirm that indoor SHS levels continue to be unsafe outside of the Ramadan period.

Conclusions

Unsafe levels of indoor air pollution were found in public places in multiple cities, and indoor smoking was commonly found in various types of public venues in Lebanon. To fully protect the public's health from this source of indoor air pollution, smoking restrictions in Lebanon should also apply to venues where water-pipe smoking occurs. One challenge in protecting the public from SHS exposure in Lebanon might arise from the cultural significance of water-pipe use, which is popular throughout the Eastern Mediterranean Region.21 In the present study water-pipe smoking was observed in over half of the venues visited. Policies that prohibit smoking indoors are the most effective strategy to reduce non-smokers' exposure to SHS. Comprehensive clean indoor air laws, which completely ban all indoor smoking, regardless of smoking type or physical features of the venue, have received strong support in various countries22–24 and have contributed to reductions in adverse health outcomes.18–20 Moreover, neighbouring Syria recently announced a comprehensive clean indoor air law which includes water-pipe smoking.25 A comprehensive ban on indoor smoking in Lebanese workplaces would unambiguously communicate the risks associated with exposure to all forms of tobacco smoke. In the absence of a comprehensive ban, the health benefits that have been realised in countries prohibiting indoor smoking are unlikely to be realised in Lebanon. The signing and ratification of the FCTC by the Lebanese government is an important step in achieving the nation's public health goals and demonstrates a commitment to the protection of all who live there. However, the implementation of smoke-free legislation is needed to ensure full protection from this preventable public health problem. Secondhand smoke is a major cause of preventable disease and mortality. To protect the public's health, WHO is encouraging nations to adopt smoking restrictions in public places through its Framework Convention on Tobacco Control (FCTC). This study assessed the prevalence of cigarette and water-pipe smoking among a convenience sample of 28 enclosed public places in six Lebanese cities, and measured PM2.5 concentrations within those venues. Although the Lebanese government ratified the FCTC in 2005, tobacco smoking, particularly through the use of water-pipes, was observed in 27 out of the 28 of the venues sampled. Particulate pollution within the smoking-permitted venues was observed to be at unsafe levels, with an overall mean level of 342 μg/m3. Results also show that water-pipe and cigarette use often co-occur within the same venue. This can make separate measurement of each type of SHS emission difficult in field settings and research documenting water-pipe SHS is greatly needed. Venues with a greater density of water-pipe smokers were found to have similar PM2.5 levels as venues with a greater density of cigarette smokers. The data suggest that water-pipe smoke emissions are an important source of indoor particulate pollution in public venues. Enforcement mechanisms are needed to ensure that ratifying nations conform to Article 8 of the FCTC.
  20 in total

1.  Water pipe (Sisha) smoking in cafes in Egypt.

Authors:  Ebenezer Israel; Maged El-Setouhy; Shahinaz Gadalla; El Saeed Ali Aoun; Nabiel Mikhail; Mostafa K Mohamed
Journal:  J Egypt Soc Parasitol       Date:  2003-12

2.  Indoor air quality in hospitality venues before and after implementation of a clean indoor air law--Western New York, 2003.

Authors: 
Journal:  MMWR Morb Mortal Wkly Rep       Date:  2004-11-12       Impact factor: 17.586

3.  Reduction in fine particulate air pollution and mortality: Extended follow-up of the Harvard Six Cities study.

Authors:  Francine Laden; Joel Schwartz; Frank E Speizer; Douglas W Dockery
Journal:  Am J Respir Crit Care Med       Date:  2006-01-19       Impact factor: 21.405

4.  Respiratory symptoms, pulmonary function, and markers of inflammation among bar workers before and after a legislative ban on smoking in public places.

Authors:  Daniel Menzies; Arun Nair; Peter A Williamson; Stuart Schembri; Mudher Z H Al-Khairalla; Martyn Barnes; Tom C Fardon; Lesley McFarlane; Gareth J Magee; Brian J Lipworth
Journal:  JAMA       Date:  2006-10-11       Impact factor: 56.272

5.  Ultrafine particle emissions from waterpipes.

Authors:  Ch Monn; Ph Kindler; A Meile; O Brändli
Journal:  Tob Control       Date:  2007-12       Impact factor: 7.552

6.  Waterpipe-associated particulate matter emissions.

Authors:  Wasim Maziak; Samer Rastam; Iman Ibrahim; Kenneth D Ward; Thomas Eissenberg
Journal:  Nicotine Tob Res       Date:  2008-03       Impact factor: 4.244

7.  After the smoke has cleared: evaluation of the impact of a new national smoke-free law in New Zealand.

Authors:  R Edwards; G Thomson; N Wilson; A Waa; C Bullen; D O'Dea; H Gifford; M Glover; M Laugesen; A Woodward
Journal:  Tob Control       Date:  2008-02       Impact factor: 7.552

8.  Attitudes and beliefs about secondhand smoke and smoke-free policies in four countries: findings from the International Tobacco Control Four Country Survey.

Authors:  Andrew Hyland; Cheryl Higbee; Ron Borland; Mark Travers; Gerard Hastings; Geoffrey T Fong; K Michael Cummings
Journal:  Nicotine Tob Res       Date:  2009-05-19       Impact factor: 4.244

9.  Fine particulate air pollution and hospital admission for cardiovascular and respiratory diseases.

Authors:  Francesca Dominici; Roger D Peng; Michelle L Bell; Luu Pham; Aidan McDermott; Scott L Zeger; Jonathan M Samet
Journal:  JAMA       Date:  2006-03-08       Impact factor: 56.272

10.  A critique of the WHO TobReg's "Advisory Note" report entitled: "Waterpipe tobacco smoking: health effects, research needs and recommended actions by regulators".

Authors:  Kamal Chaouachi
Journal:  J Negat Results Biomed       Date:  2006-11-17
View more
  11 in total

1.  Indoor air quality in Virginia waterpipe cafes.

Authors:  Caroline Oates Cobb; Andrea Rae Vansickel; Melissa D Blank; Kade Jentink; Mark J Travers; Thomas Eissenberg
Journal:  Tob Control       Date:  2012-03-24       Impact factor: 7.552

2.  Secondhand smoke in waterpipe tobacco venues in Istanbul, Moscow, and Cairo.

Authors:  Katherine A Moon; Hoda Magid; Christine Torrey; Ana M Rule; Jacqueline Ferguson; Jolie Susan; Zhuolu Sun; Salahaddin Abubaker; Vladimir Levshin; Aslı Çarkoğlu; Ghada Nasr Radwan; Maha El-Rabbat; Joanna Cohen; Paul Strickland; Ana Navas-Acien; Patrick N Breysse
Journal:  Environ Res       Date:  2015-10       Impact factor: 6.498

Review 3.  Water Pipe (Hookah) Smoking and Cardiovascular Disease Risk: A Scientific Statement From the American Heart Association.

Authors:  Aruni Bhatnagar; Wasim Maziak; Thomas Eissenberg; Kenneth D Ward; George Thurston; Brian A King; Erin L Sutfin; Caroline O Cobb; Merlyn Griffiths; Larry B Goldstein; Mary Rezk-Hanna
Journal:  Circulation       Date:  2019-05-07       Impact factor: 29.690

4.  Waterpipe smoking: the pressing need for risk communication.

Authors:  Wasim Maziak; Olatokunbo Osibogun; Taghrid Asfar
Journal:  Expert Rev Respir Med       Date:  2019-09-20       Impact factor: 3.772

5.  Biomarkers of Secondhand Smoke Exposure in Waterpipe Tobacco Venue Employees in Istanbul, Moscow, and Cairo.

Authors:  Katherine A Moon; Ana M Rule; Hoda S Magid; Jacqueline M Ferguson; Jolie Susan; Zhuolu Sun; Christine Torrey; Salahaddin Abubaker; Vladimir Levshin; Asli Çarkoglu; Ghada Nasr Radwan; Maha El-Rabbat; Joanna E Cohen; Paul Strickland; Patrick N Breysse; Ana Navas-Acien
Journal:  Nicotine Tob Res       Date:  2018-03-06       Impact factor: 4.244

Review 6.  Waterpipe tobacco smoking legislation and policy enactment: a global analysis.

Authors:  Mohammed Jawad; Lama El Kadi; Sanaa Mugharbil; Rima Nakkash
Journal:  Tob Control       Date:  2014-12-30       Impact factor: 7.552

7.  Bladder Cancer in Lebanon: Incidence and Comparison to Regional and Western Countries.

Authors:  Najla A Lakkis; Salim M Adib; Ghassan N Hamadeh; Rana T El-Jarrah; Mona H Osman
Journal:  Cancer Control       Date:  2018 Jan-Dec       Impact factor: 3.302

8.  Cervix Uteri Cancer in Lebanon: Incidence, Temporal Trends, and Comparison to Countries From Different Regions in the World.

Authors:  Najla A Lakkis; Mona H Osman; Reem M Abdallah
Journal:  Cancer Control       Date:  2022 Jan-Dec       Impact factor: 3.302

Review 9.  Environmental monitoring of secondhand smoke exposure.

Authors:  Benjamin J Apelberg; Lisa M Hepp; Erika Avila-Tang; Lara Gundel; S Katharine Hammond; Melbourne F Hovell; Andrew Hyland; Neil E Klepeis; Camille C Madsen; Ana Navas-Acien; James Repace; Jonathan M Samet; Patrick N Breysse
Journal:  Tob Control       Date:  2012-09-04       Impact factor: 7.552

Review 10.  Particulate matter and atherosclerosis: a bibliometric analysis of original research articles published in 1973-2014.

Authors:  Feifei Wang; Xiaofeng Jia; Xianliang Wang; Yongdong Zhao; Weidong Hao
Journal:  BMC Public Health       Date:  2016-04-19       Impact factor: 3.295

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.