| Literature DB >> 20378588 |
Georges Saade1, Andrew B Seidenberg, Vaughan W Rees, Zaher Otrock, Gregory N Connolly.
Abstract
BACKGROUND: To date, Lebanon has failed to enact comprehensive clean indoor air laws despite ratification of the Framework Convention on Tobacco Control (FCTC), which calls for the protection of non-smokers from exposure to secondhand tobacco smoke (SHS). Complicating the problem of SHS exposure in Lebanon is the widespread use of the tobacco water-pipe. While most research on SHS has involved cigarette smoking as a source of emissions, other sources, including tobacco water-pipes, may be an important contributor.Entities:
Mesh:
Substances:
Year: 2010 PMID: 20378588 PMCID: PMC2989171 DOI: 10.1136/tc.2009.030460
Source DB: PubMed Journal: Tob Control ISSN: 0964-4563 Impact factor: 7.552
Summary statistics for each venue visited
| Venue No | PM2.5 levels (μg/m3) | ASDWP (No of smokers/100 m3) | ASDCIG (No of smokers/100 m3) | Volume (m3) | Venue type | City |
| Venues with greater ASDWP | ||||||
| 1 | 723 | 4.25 | 0.65 | 1683 | Cafe-restaurant | Antelias |
| 2 | 648 | 0.98 | 0.16 | 1290 | Cafe | Tripoli |
| 3 | 540 | 3.03 | 1.13 | 2380 | Cafe-restaurant | Antelias |
| 4 | 523 | 2.14 | 1.44 | 749 | Restaurant | Antelias |
| 5 | 505 | 1.63 | 0.13 | 796 | Cafe-restaurant | Antelias |
| 6 | 477 | 5.80 | 1.79 | 112 | Cafe | Tripoli |
| 7 | 355 | 2.90 | 0.00 | 396 | Cafe | Tripoli |
| 8 | 342 | 1.75 | 0.20 | 646 | Cafe-restaurant | Beirut |
| 9 | 304 | 2.53 | 1.43 | 91 | Cafe | Saida |
| 10 | 260 | 1.76 | 0.33 | 598 | Cafe-restaurant | Beirut |
| 11 | 233 | 2.67 | 1.33 | 75 | Cafe | Saida |
| 12 | 228 | 3.46 | 0.58 | 433 | Cafe-restaurant | Antelias |
| 13 | 78 | 0.55 | 0.28 | 1125 | Cafe-restaurant | Beirut |
| 14 | 39 | 1.74 | 0.98 | 287 | Cafe | Saida |
| Venues with greater ASDCIG | ||||||
| 15 | 1324 | 0.00 | 19.80 | 884 | Night club | Batroun |
| 16 | 506 | 0.00 | 1.58 | 557 | Pub-restaurant | Beirut |
| 17 | 441 | 0.00 | 2.38 | 231 | Hospital cafeteria | Koura |
| 18 | 366 | 1.80 | 2.73 | 183 | Cafe | Saida |
| 19 | 316 | 0.00 | 1.40 | 358 | Cafe-restaurant | Beirut |
| 20 | 252 | 0.00 | 3.11 | 106 | Cafe-restaurant | Beirut |
| 21 | 241 | 0.00 | 0.80 | 287 | Cafe-restaurant | Saida |
| 22 | 181 | 0.00 | 4.19 | 253 | Restaurant | Beirut |
| 23 | 101 | 0.00 | 1.95 | 128 | Hospital cafeteria | Koura |
| 24 | 93 | 0.00 | 3.85 | 273 | Pub-restaurant | Batroun |
| 25 | 73 | 0.00 | 2.07 | 58 | Restaurant | Beirut |
| 26 | 56 | 0.00 | 0.27 | 1125 | Cafe-restaurant | Beirut |
| 27 | 28 | 0.00 | 0.10 | 3888 | Shopping mall | Beirut |
| Venues with no observed smoking | ||||||
| 28 | 6 | 0.00 | 0.00 | 120 | Cafe | Beirut |
ASDCIG, active cigarette smoker density; ASDWP, active water-pipe smoker density.
Figure 1Mean PM2.5 levels and relative proportions of water-pipe and cigarette smokers observed for venues with greater water-pipe and cigarette smoker densities.