Development of a wearable glucose sensor; studies in healthy volunteers and in diabetic patients.

A L Aalders1, F J Schmidt, A J Schoonen, I R Broek, A G Maessen, H Doorenbos.   

Abstract

A glucose sensor with a subcutaneous dialysis system was tested in six healthy volunteers during an oral glucose tolerance test and in ten diabetic patients with hyperglycemia during rapid decline of blood glucose levels. There was a good correlation between sensor and blood glucose values. During oral glucose tolerance tests in the volunteers, there was a mean delay of 4.4 minutes in the rise of the value registered subcutaneously and of 8.2 minutes in the fall of the curves. In the diabetic patients the maximum delay was 22 minutes. Nine days after insertion of the dialysis system it was still functioning well.

Entities:  

Mesh:

Year:  1991        PMID: 2037386

Source DB:  PubMed          Journal:  Int J Artif Organs        ISSN: 0391-3988            Impact factor:   1.595


  8 in total

Review 1.  Can hypoglycaemia be predicted before its onset?

Authors:  P Lönnroth
Journal:  Diabetologia       Date:  1996-05       Impact factor: 10.122

2.  Minimizing the impact of time lag variability on accuracy evaluation of continuous glucose monitoring systems.

Authors:  Cosimo Scuffi; Fausto Lucarelli; Francesco Valgimigli
Journal:  J Diabetes Sci Technol       Date:  2012-11-01

3.  Development of a highly responsive needle-type glucose sensor using polyimide for a wearable artificial endocrine pancreas.

Authors:  Shinji Ichimori; Kenro Nishida; Seiya Shimoda; Taiji Sekigami; Yasuto Matsuo; Kenshi Ichinose; Motoaki Shichiri; Michiharu Sakakida; Eiichi Araki
Journal:  J Artif Organs       Date:  2006       Impact factor: 1.731

4.  Interstitium versus Blood Equilibrium in Glucose Concentration and its Impact on Subcutaneous Continuous Glucose Monitoring Systems.

Authors:  Cosimo Scuffi
Journal:  Eur Endocrinol       Date:  2014-02-28

5.  Putative delays in interstitial fluid (ISF) glucose kinetics can be attributed to the glucose sensing systems used to measure them rather than the delay in ISF glucose itself.

Authors:  Gayane Voskanyan; D Barry Keenan; John J Mastrototaro; Garry M Steil
Journal:  J Diabetes Sci Technol       Date:  2007-09

6.  On line continuous monitoring of subcutaneous tissue glucose in men by combining portable glucosensor with microdialysis.

Authors:  C Meyerhoff; F Bischof; F Sternberg; H Zier; E F Pfeiffer
Journal:  Diabetologia       Date:  1992-11       Impact factor: 10.122

7.  Continuous monitoring of lactate during exercise in humans using subcutaneous and transcutaneous microdialysis.

Authors:  J de Boer; H Plijter-Groendijk; K R Visser; G A Mook; J Korf
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1994

8.  Measurement delay associated with the Guardian RT continuous glucose monitoring system.

Authors:  C Wei; D J Lunn; C L Acerini; J M Allen; A M Larsen; M E Wilinska; D B Dunger; R Hovorka
Journal:  Diabet Med       Date:  2010-01       Impact factor: 4.359

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.