Literature DB >> 20373386

Systolic 3D first-pass myocardial perfusion MRI: Comparison with diastolic imaging in healthy subjects.

Taehoon Shin1, Gerald M Pohost, Krishna S Nayak.   

Abstract

Three-dimensional (3D) first-pass myocardial perfusion imaging (MPI) is a promising alternative to conventional two-dimensional multislice MPI due to its contiguous spatial coverage that is beneficial for estimating the size of perfusion defects. Data acquisition at mid-diastole is a typical choice for 3D MPI yet is sensitive to arrhythmia and variations in R-R interval that are common in cardiac patients. End systole is the second longest quiescent cardiac phase and is known to be less sensitive to the R-R variability. Therefore, 3D MPI with systolic acquisition may be advantageous in patients with severe arrhythmia once it is proven to be comparable to diastolic MPI in subjects with negligible R-R variation. In this work, we demonstrate the feasibility of 3D MPI with systolic data acquisition in five healthy subjects. We performed 3D MPI experiments in which 3D perfusion data were acquired at both end-systole and mid-diastole of every R-R interval and analyzed the similarity between resulting time intensity curves (TIC) from the two data sets. The correlation between systolic and diastolic TICs was extremely high (mean = 0.9841; standard deviation = 0.0166), and there was a significant linear correlation between the two time intensity curve upslopes and peak enhancements (P < 0.001).

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20373386     DOI: 10.1002/mrm.22315

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  13 in total

1.  Feasibility of high temporal resolution breast DCE-MRI using compressed sensing theory.

Authors:  Haoyu Wang; Yanwei Miao; Kun Zhou; Yanming Yu; Shanglian Bao; Qiang He; Yongming Dai; Stephanie Y Xuan; Bisher Tarabishy; Yongquan Ye; Jiani Hu
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

2.  Accelerating free breathing myocardial perfusion MRI using multi coil radial k-t SLR.

Authors:  Sajan Goud Lingala; Edward DiBella; Ganesh Adluru; Christopher McGann; Mathews Jacob
Journal:  Phys Med Biol       Date:  2013-09-27       Impact factor: 3.609

3.  Three-dimensional first-pass myocardial perfusion MRI using a stack-of-spirals acquisition.

Authors:  Taehoon Shin; Krishna S Nayak; Juan M Santos; Dwight G Nishimura; Bob S Hu; Michael V McConnell
Journal:  Magn Reson Med       Date:  2012-05-03       Impact factor: 4.668

4.  All-systolic non-ECG-gated myocardial perfusion MRI: Feasibility of multi-slice continuous first-pass imaging.

Authors:  Behzad Sharif; Reza Arsanjani; Rohan Dharmakumar; C Noel Bairey Merz; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2015-06-06       Impact factor: 4.668

5.  Quantitative three-dimensional cardiovascular magnetic resonance myocardial perfusion imaging in systole and diastole.

Authors:  Manish Motwani; Ananth Kidambi; Steven Sourbron; Timothy A Fairbairn; Akhlaque Uddin; Sebastian Kozerke; John P Greenwood; Sven Plein
Journal:  J Cardiovasc Magn Reson       Date:  2014-02-24       Impact factor: 5.364

6.  Free breathing three-dimensional late gadolinium enhancement cardiovascular magnetic resonance using outer volume suppressed projection navigators.

Authors:  Rajiv G Menon; G Wilson Miller; Jean Jeudy; Sanjay Rajagopalan; Taehoon Shin
Journal:  Magn Reson Med       Date:  2016-04-28       Impact factor: 4.668

7.  Defining the optimal systolic phase targets using absolute delay time for reconstructions in dual-source coronary CT angiography.

Authors:  Csilla Celeng; Harshna Vadvala; Stefan Puchner; Amit Pursnani; Umesh Sharma; Attila Kovacs; Pâl Maurovich-Horvat; Udo Hoffmann; Brian Ghoshhajra
Journal:  Int J Cardiovasc Imaging       Date:  2015-09-03       Impact factor: 2.357

8.  Towards a five-minute comprehensive cardiac MR examination using highly accelerated parallel imaging with a 32-element coil array: feasibility and initial comparative evaluation.

Authors:  Jian Xu; Daniel Kim; Ricardo Otazo; Monvadi B Srichai; Ruth P Lim; Leon Axel; Kelly Anne Mcgorty; Thoralf Niendorf; Daniel K Sodickson
Journal:  J Magn Reson Imaging       Date:  2012-11-29       Impact factor: 4.813

9.  Quantification of myocardial blood flow with cardiovascular magnetic resonance throughout the cardiac cycle.

Authors:  Manish Motwani; Ananth Kidambi; Akhlaque Uddin; Steven Sourbron; John P Greenwood; Sven Plein
Journal:  J Cardiovasc Magn Reson       Date:  2015-01-29       Impact factor: 5.364

Review 10.  A review of 3D first-pass, whole-heart, myocardial perfusion cardiovascular magnetic resonance.

Authors:  Merlin J Fair; Peter D Gatehouse; Edward V R DiBella; David N Firmin
Journal:  J Cardiovasc Magn Reson       Date:  2015-08-01       Impact factor: 5.364