Literature DB >> 2033951

Measurement of finger joint angles and maximum finger forces during cylinder grip activity.

J W Lee1, K Rim.   

Abstract

Finger joint angles and finger forces during maximal cylindrical grasping were measured using multi-camera photogrammetry and pressure-sensitive sheets, respectively. The experimental data were collected from four healthy subjects gripping cylinders of five different sizes. For joint angles, an image analysis system was used to digitize slides showing markers. During the calibration of the camera system, both the nonlinear least square and the direct linear transform methods were applied and compared, the former providing the fewer errors; it was used to determine joint angles. Data were collected from the pressure-sensitive grip films by using the same image analysis system as used in the collection of the joint angle data. The method of using pressure-sensitive sheets provided an estimation of the weighted centre of the phalangeal forces. Results indicate that finger flexion angles at the metacarpophalangeal and proximal interphalangeal joints gradually increase as cylinder diameter decreases, but that at the distal interphalangeal joint the angle remains constant throughout all cylinder sizes. It was also found that most of the radio-ulnar deviation and the axial rotation angles at the finger joints deviate from zero, but the deviations are small. For the force measurement, it was found that total finger force increases as cylinder size decreases, and the phalangeal force centres are not located at the mid-points of the phalanges. The data obtained in this experiment would be useful for muscle force predictions and for the design of handles.

Entities:  

Mesh:

Year:  1991        PMID: 2033951     DOI: 10.1016/0141-5425(91)90062-c

Source DB:  PubMed          Journal:  J Biomed Eng        ISSN: 0141-5425


  10 in total

1.  An artificial grasping evaluation system for the paralysed hand.

Authors:  M C de Castro; A Cliquet Júnior
Journal:  Med Biol Eng Comput       Date:  2000-05       Impact factor: 2.602

2.  Multi-digit maximum voluntary torque production on a circular object.

Authors:  Jae Kun Shim; Junfeng Huang; Alexander W Hooke; Mark L Latsh; Vladimir M Zatsiorsky
Journal:  Ergonomics       Date:  2007-05       Impact factor: 2.778

3.  Hand Motion Analysis during the Execution of the Action Research Arm Test Using Multiple Sensors.

Authors:  Jesus Fernando Padilla-Magaña; Esteban Peña-Pitarch; Isahi Sánchez-Suarez; Neus Ticó-Falguera
Journal:  Sensors (Basel)       Date:  2022-04-24       Impact factor: 3.847

4.  Measurement of three-joint-finger motions: reality or fancy? A three-dimensional anatomical approach.

Authors:  R Degeorges; C Oberlin
Journal:  Surg Radiol Anat       Date:  2003-05-20       Impact factor: 1.246

5.  Analysis of the effects of surface stiffness on the contact interaction between a finger and a cylindrical handle using a three-dimensional hybrid model.

Authors:  John Z Wu; Ren G Dong; Christopher M Warren; Daniel E Welcome; Thomas W McDowell
Journal:  Med Eng Phys       Date:  2014-04-13       Impact factor: 2.242

6.  Automated pressure map segmentation for quantifying phalangeal kinetics during cylindrical gripping.

Authors:  Erik W Sinsel; Daniel S Gloekler; Bryan M Wimer; Christopher M Warren; John Z Wu; Frank L Buczek
Journal:  Med Eng Phys       Date:  2015-12-18       Impact factor: 2.242

7.  Prehension synergies: principle of superposition and hierarchical organization in circular object prehension.

Authors:  Jae Kun Shim; Jaebum Park
Journal:  Exp Brain Res       Date:  2007-02-06       Impact factor: 2.064

8.  Parameters influencing hand grip strength measured with the manugraphy system.

Authors:  Alice Wichelhaus; Christoph Harms; Julia Neumann; Steffen Ziegler; Günther Kundt; Karl Josef Prommersberger; Thomas Mittlmeier; Marion Mühldorfer-Fodor
Journal:  BMC Musculoskelet Disord       Date:  2018-02-14       Impact factor: 2.362

9.  Measurement of Flexion Angle of the Finger Joint during Cylinder Gripping Using a Three-Dimensional Bone Model Built by X-Ray Computed Tomography.

Authors:  Satoshi Shimawaki; Takuma Murai; Masataka Nakabayashi; Hideharu Sugimoto
Journal:  Appl Bionics Biomech       Date:  2019-01-06       Impact factor: 1.781

10.  Research on Monocular-Vision-Based Finger-Joint-Angle-Measurement System.

Authors:  Yongfei Feng; Mingwei Zhong; Fangyan Dong
Journal:  Sensors (Basel)       Date:  2022-09-26       Impact factor: 3.847