Literature DB >> 20336824

Effects of glial cells on electrode impedance recorded from neuralprosthetic devices in vitro.

John P Frampton1, Matthew R Hynd, Michael L Shuler, William Shain.   

Abstract

Neural prosthetic devices hold the potential to be used in the treatment of a variety of neurological disorders. However, their long-term clinical success is currently limited by the ability to achieve stable interfaces between devices and the CNS. Immunohistochemical analysis has shown that cellular responses occur in tissue surrounding implanted devices. These cellular responses have been correlated with the impedance measured from device electrodes, leading to the hypothesis that a possible mechanism resulting in inconsistent device performance is the formation of an electrically insulating glial sheath at the implantation site. However, little is known about what cellular and tissue changes affect impedance values and thus contribute to the decreases in electrode performance. We have designed an in vitro system in which cell conditions can be varied within an artificial tissue matrix surrounding a neural prosthetic device. In this study, high-density cultures of glial cells were analyzed by immunohistochemical methods and impedance spectroscopy. Astrocytes and microglia were cultured at various ratios within the matrix surrounding the probes, and were observed over a period of 2 weeks. Cell seeding conditions and confocal images were compared to impedance data to enable the effects of glial cell type on electrode impedance to be determined.

Entities:  

Mesh:

Year:  2010        PMID: 20336824     DOI: 10.1007/s10439-010-9911-y

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  15 in total

1.  Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies.

Authors:  J P Harris; J R Capadona; R H Miller; B C Healy; K Shanmuganathan; S J Rowan; C Weder; D J Tyler
Journal:  J Neural Eng       Date:  2011-11-02       Impact factor: 5.379

2.  Chronically Implanted, Nafion-Coated Ag/AgCl Reference Electrodes for Neurochemical Applications.

Authors:  Parastoo Hashemi; Paul L Walsh; Thomas S Guillot; Julie Gras-Najjar; Pavel Takmakov; Fulton T Crews; R Mark Wightman
Journal:  ACS Chem Neurosci       Date:  2011-11-16       Impact factor: 4.418

3.  Tissue engineering the monosynaptic circuit of the stretch reflex arc with co-culture of embryonic motoneurons and proprioceptive sensory neurons.

Authors:  Xiufang Guo; Jennifer E Ayala; Mercedes Gonzalez; Maria Stancescu; Stephen Lambert; James J Hickman
Journal:  Biomaterials       Date:  2012-05-15       Impact factor: 12.479

4.  An electrically resistive sheet of glial cells for amplifying signals of neuronal extracellular recordings.

Authors:  R Matsumura; H Yamamoto; M Niwano; A Hirano-Iwata
Journal:  Appl Phys Lett       Date:  2016-01-11       Impact factor: 3.791

5.  In vivo polymerization of poly(3,4-ethylenedioxythiophene) in the living rat hippocampus does not cause a significant loss of performance in a delayed alternation task.

Authors:  Liangqi Ouyang; Crystal L Shaw; Chin-Chen Kuo; Amy L Griffin; David C Martin
Journal:  J Neural Eng       Date:  2014-02-06       Impact factor: 5.379

6.  A comparison of neuroinflammation to implanted microelectrodes in rat and mouse models.

Authors:  Kelsey A Potter-Baker; Madhumitha Ravikumar; Alan A Burke; William D Meador; Kyle T Householder; Amy C Buck; Smrithi Sunil; Wade G Stewart; Jake P Anna; William H Tomaszewski; Jeffrey R Capadona
Journal:  Biomaterials       Date:  2014-04-19       Impact factor: 12.479

7.  Protease-degradable PEG-maleimide coating with on-demand release of IL-1Ra to improve tissue response to neural electrodes.

Authors:  Stacie M Gutowski; James T Shoemaker; Kellie L Templeman; Yang Wei; Robert A Latour; Ravi V Bellamkonda; Michelle C LaPlaca; Andrés J García
Journal:  Biomaterials       Date:  2015-01-12       Impact factor: 12.479

8.  Spatial and temporal characteristics of V1 microstimulation during chronic implantation of a microelectrode array in a behaving macaque.

Authors:  T S Davis; R A Parker; P A House; E Bagley; S Wendelken; R A Normann; B Greger
Journal:  J Neural Eng       Date:  2012-11-27       Impact factor: 5.379

9.  Optimizing a rodent model of Parkinson's disease for exploring the effects and mechanisms of deep brain stimulation.

Authors:  Karl Nowak; Eilhard Mix; Jan Gimsa; Ulf Strauss; Kiran Kumar Sriperumbudur; Reiner Benecke; Ulrike Gimsa
Journal:  Parkinsons Dis       Date:  2011-04-05

10.  Hydrogel-electrospun fiber mat composite coatings for neural prostheses.

Authors:  Ning Han; Shreyas S Rao; Jed Johnson; Kunal S Parikh; Patrick A Bradley; John J Lannutti; Jessica O Winter
Journal:  Front Neuroeng       Date:  2011-03-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.