Literature DB >> 20333382

Detection of corona enhancement of hypervascular hepatocellular carcinoma by C-arm dual-phase cone-beam CT during hepatic arteriography.

Shiro Miyayama1, Masashi Yamashiro, Miho Okuda, Yuichi Yoshie, Yoshiko Nakashima, Hiroshi Ikeno, Nobuaki Orito, Osamu Matsui.   

Abstract

The purpose of this study was to evaluate the detectability of corona enhancement around the hypervascular hepatocellular carcinoma (HCC) by dual-phase cone-beam computed tomography during hepatic arteriography (CBCTHA). Dual-phase CBCTHA was performed for 71 HCC lesions (mean ± SD 1.7 ± 0.9 cm), including seven presenting a nodule-in-nodule appearance and nine hypervascular pseudolesions. The first scan was performed during injection of 30-40 ml half-diluted contrast material at a rate of 1.5-2 ml/s through the hepatic artery. Scanning was initiated 7 s after the beginning of contrast material injection. The second scan was started 30 s after the end of the first scan. Detectability of corona enhancement on second-phase CBCTHA was evaluated. Thickness of corona enhancement was also analyzed as thin (≤2 mm) or thick (>2 mm). Corona enhancement was detected in 63 (88.7%) of 71 tumors (1.8 ± 0.9 cm), but it was not detected in eight tumors (1.0 ± 0.2 cm). Thin corona enhancement was seen in 18 tumors (1.2 ± 0.5 cm), and thick corona enhancement was seen in 45 tumors (2.0 ± 0.9 cm). There was a significant difference in tumor diameter between tumors with and those without corona enhancement (P = 0.0157) and between thin and thick corona enhancement (P = 0.001). In all seven early-stage tumors, corona enhancement was demonstrated around the hypervascular focus within the hypovascular tumor portion. None of the nine pseudolesions showed any corona enhancement. Dual-phase CBCTHA depicted corona enhancement in 88.7% of hypervascular HCC lesions. This technique may improve the diagnostic accuracy of HCC.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20333382     DOI: 10.1007/s00270-010-9835-9

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  27 in total

1.  Image quality improvements in C-Arm CT (CACT) for liver oncology applications: preliminary study in rabbits.

Authors:  Vania Tacher; Nikhil Bhagat; Pramod V Rao; Mingde Lin; Dirk Schäfer; Niels Noordhoek; Peter Eshuis; Alessandro Radaelli; Eleni Liapi; Michael Grass; Jean-François Geschwind
Journal:  Minim Invasive Ther Allied Technol       Date:  2013-07-09       Impact factor: 2.442

2.  Artifacts caused by insufficient contrast medium filling during C-arm cone-beam CT scans: a phantom study.

Authors:  Mitsuaki Terabe; Hajime Ichikawa; Toyohiro Kato; Kichiro Koshida
Journal:  Radiol Phys Technol       Date:  2013-06-18

Review 3.  Efficacy of cone-beam computed tomography during transcatheter arterial chemoembolization for hepatocellular carcinoma.

Authors:  Shiro Miyayama; Masashi Yamashiro; Yuki Hattori; Nobuaki Orito; Ken Matsui; Kazunobu Tsuji; Miki Yoshida; Osamu Matsui
Journal:  Jpn J Radiol       Date:  2011-07-24       Impact factor: 2.374

Review 4.  How I do it: Cone-beam CT during transarterial chemoembolization for liver cancer.

Authors:  Vania Tacher; Alessandro Radaelli; MingDe Lin; Jean-François Geschwind
Journal:  Radiology       Date:  2015-02       Impact factor: 11.105

5.  Intraprocedural C-arm dual-phase cone-beam CT: can it be used to predict short-term response to TACE with drug-eluting beads in patients with hepatocellular carcinoma?

Authors:  Romaric Loffroy; MingDe Lin; Gayane Yenokyan; Pramod P Rao; Nikhil Bhagat; Niels Noordhoek; Alessandro Radaelli; Järl Blijd; Eleni Liapi; Jean-François Geschwind
Journal:  Radiology       Date:  2012-11-09       Impact factor: 11.105

6.  Diagnostic accuracy of C-arm CT during selective transcatheter angiography for hepatocellular carcinoma: comparison with intravenous contrast-enhanced, biphasic, dynamic MDCT.

Authors:  Hiroki Higashihara; Keigo Osuga; Hiromitsu Onishi; Atsushi Nakamoto; Takahiro Tsuboyama; Noboru Maeda; Masatoshi Hori; Tonsok Kim; Noriyuki Tomiyama
Journal:  Eur Radiol       Date:  2011-11-26       Impact factor: 5.315

7.  Dual-phase cone-beam computed tomography to see, reach, and treat hepatocellular carcinoma during drug-eluting beads transarterial chemo-embolization.

Authors:  Vania Tacher; Mingde Lin; Nikhil Bhagat; Nadine Abi Jaoudeh; Alessandro Radaelli; Niels Noordhoek; Bart Carelsen; Bradford J Wood; Jean-François Geschwind
Journal:  J Vis Exp       Date:  2013-12-02       Impact factor: 1.355

8.  C-arm dual-phase cone-beam CT: a revolutionary real-time imaging modality to assess drug-eluting beads TACE success in liver cancer patients.

Authors:  Romaric Loffroy; Sylvain Favelier; Violaine Cherblanc; Louis Estivalet
Journal:  Quant Imaging Med Surg       Date:  2013-08

9.  Semiautomatic volumetric tumor segmentation for hepatocellular carcinoma: comparison between C-arm cone beam computed tomography and MRI.

Authors:  Vania Tacher; MingDe Lin; Michael Chao; Lars Gjesteby; Nikhil Bhagat; Abdelkader Mahammedi; Roberto Ardon; Benoit Mory; Jean-François Geschwind
Journal:  Acad Radiol       Date:  2013-04       Impact factor: 3.173

Review 10.  C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications.

Authors:  Chiara Floridi; Alessandro Radaelli; Nadine Abi-Jaoudeh; Michael Grass; Micheal Grass; MingDe Lin; Ming De Lin; Melanie Chiaradia; Jean-Francois Geschwind; Hicham Kobeiter; Hishman Kobeiter; Ettore Squillaci; Geert Maleux; Andrea Giovagnoni; Luca Brunese; Bradford Wood; Gianpaolo Carrafiello; Antonio Rotondo
Journal:  Radiol Med       Date:  2014-07-11       Impact factor: 3.469

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.