OBJECTIVE: The objective of our study was to evaluate a new 3D fast spoiled gradient-recalled echo (FSPGR) sequence referred to as modified liver acceleration volume acquisition (LAVA) for high-resolution gadolinium-enhanced dual arterial phase liver MRI and to determine the effect of this technique on the timing of the contrast bolus and lesion detection. MATERIALS AND METHODS: Gadolinium-enhanced dual arterial phase liver MRI was performed in 109 patients using a modified LAVA sequence that supports adaptive 2D centric view ordering, efficient 2D autocalibrated acceleration, and partial-Fourier to achieve faster scan times while maintaining the same slice thickness, resolution, and coverage as single-phase imaging. After a fixed 20-second scan delay, a modified LAVA acquisition required a single 24- to 26-second breath-hold for two arterial phases with 56-60 slices per pass. Images were reviewed for timing relative to liver enhancement, lesion conspicuity, and lesion detection. Liver lesion depiction was evaluated qualitatively and quantitatively. A control group of 109 patients underwent imaging using a single arterial phase 3D FSPGR sequence, which was also performed with a fixed 20-second scan delay. RESULTS: The single arterial phase images produced optimal timing in the middle or late arterial phase in 79 (72%) of the 109 control group patients compared with 99 (91%) of the 109 study group patients who underwent imaging using a dynamic modified LAVA dual arterial phase sequence. For the modified LAVA sequence, the first-pass images were obtained during the mid arterial phase in 34 patients (31%). The second-pass images were obtained during the mid arterial phase in 51 patients (47%) and late arterial phase in 26 patients (24%). Sixty-two patients had liver lesions showing greater conspicuity--on the first phase in 17 patients (27%) and second phase in 45 patients (73%). Hypovascular lesions were more conspicuous on second-phase images in 24 (86%) of 28 patients. Hypervascular lesions were more conspicuous on first-phase images in 13 patients (38%) and on second-phase images in 21 (62%) of 34 patients. The first-phase images detected 165 and 155 liver lesions, respectively, for two observers compared with 233 and 224 lesions on the second-phase images, whereas the combined dual arterial phase images detected 256 and 248 hepatic lesions. CONCLUSION: High-resolution dual arterial phase 3D FSPGR MRI improves the timing of the arterial phase of liver enhancement and provides additional information for liver lesion detection.
OBJECTIVE: The objective of our study was to evaluate a new 3D fast spoiled gradient-recalled echo (FSPGR) sequence referred to as modified liver acceleration volume acquisition (LAVA) for high-resolution gadolinium-enhanced dual arterial phase liver MRI and to determine the effect of this technique on the timing of the contrast bolus and lesion detection. MATERIALS AND METHODS:Gadolinium-enhanced dual arterial phase liver MRI was performed in 109 patients using a modified LAVA sequence that supports adaptive 2D centric view ordering, efficient 2D autocalibrated acceleration, and partial-Fourier to achieve faster scan times while maintaining the same slice thickness, resolution, and coverage as single-phase imaging. After a fixed 20-second scan delay, a modified LAVA acquisition required a single 24- to 26-second breath-hold for two arterial phases with 56-60 slices per pass. Images were reviewed for timing relative to liver enhancement, lesion conspicuity, and lesion detection. Liver lesion depiction was evaluated qualitatively and quantitatively. A control group of 109 patients underwent imaging using a single arterial phase 3D FSPGR sequence, which was also performed with a fixed 20-second scan delay. RESULTS: The single arterial phase images produced optimal timing in the middle or late arterial phase in 79 (72%) of the 109 control group patients compared with 99 (91%) of the 109 study group patients who underwent imaging using a dynamic modified LAVA dual arterial phase sequence. For the modified LAVA sequence, the first-pass images were obtained during the mid arterial phase in 34 patients (31%). The second-pass images were obtained during the mid arterial phase in 51 patients (47%) and late arterial phase in 26 patients (24%). Sixty-two patients had liver lesions showing greater conspicuity--on the first phase in 17 patients (27%) and second phase in 45 patients (73%). Hypovascular lesions were more conspicuous on second-phase images in 24 (86%) of 28 patients. Hypervascular lesions were more conspicuous on first-phase images in 13 patients (38%) and on second-phase images in 21 (62%) of 34 patients. The first-phase images detected 165 and 155 liver lesions, respectively, for two observers compared with 233 and 224 lesions on the second-phase images, whereas the combined dual arterial phase images detected 256 and 248 hepatic lesions. CONCLUSION: High-resolution dual arterial phase 3D FSPGR MRI improves the timing of the arterial phase of liver enhancement and provides additional information for liver lesion detection.
Authors: Hersh Chandarana; Li Feng; Justin Ream; Annie Wang; James S Babb; Kai Tobias Block; Daniel K Sodickson; Ricardo Otazo Journal: Invest Radiol Date: 2015-11 Impact factor: 6.016
Authors: Manojkumar Saranathan; Dan W Rettmann; Brian A Hargreaves; Sharon E Clarke; Shreyas S Vasanawala Journal: J Magn Reson Imaging Date: 2012-02-14 Impact factor: 4.813
Authors: Mitchell A Cooper; Thanh D Nguyen; Bo Xu; Martin R Prince; Michael Elad; Yi Wang; Pascal Spincemaille Journal: Magn Reson Med Date: 2014-12-06 Impact factor: 4.668
Authors: Ryan L Brunsing; Kathryn J Fowler; Takeshi Yokoo; Guilherme Moura Cunha; Claude B Sirlin; Robert M Marks Journal: Hepatoma Res Date: 2020-09-01