Real-time glucose estimation algorithm for continuous glucose monitoring using autoregressive models.

Yenny Leal1, Winston Garcia-Gabin, Jorge Bondia, Eduardo Esteve, Wifredo Ricart, Jose-Manuel Fernández-Real, Josep Vehí.   

Abstract

BACKGROUND: Continuous glucose monitors (CGMs) present a problem of lack of accuracy, especially in the lower range, sometimes leading to missed or false hypoglycemia. A new algorithm is presented here aimed at improving the measurement accuracy and hypoglycemia detection. Its core is the estimation of blood glucose (BG) in real time (RT) from CGM intensity readings using autoregressive (AR) models.
METHODS: Eighteen patients with type 1 diabetes were monitored for three days (one at the hospital and two at home) using the CGMS Gold. For these patients, BG samples were taken every 15 min for 2 h after meals and every half hour otherwise during the first day. The relationship between the current measured by the CGMS Gold and BG was learned by an AR model, allowing its RT estimation. New capillary glucose measurements were used to correct the model BG estimations.
RESULTS: A total of 563 paired points were obtained from BG and monitor readings to validate the new algorithm. 98.5% of paired points fell in zones A+B of the Clarke error grid analysis with the proposed algorithm. The overall mean and median relative absolute differences (RADs) were 9.6% and 6.7%. Measurements meeting International Organization for Standardization (ISO) criteria were 88.7%. In the hypoglycemic range, the mean and median RADs were 8.1% and 6.0%, and measurements meeting ISO criteria were 86.7%. The sensitivity and specificity with respect to hypoglycemia detection were 91.5% and 95.0%.
CONCLUSIONS: The performance measured with both clinical and numerical accuracy metrics illustrates the improved accuracy of the proposed algorithm compared with values presented in the literature. A significant improvement in hypoglycemia detection was also observed. (c) 2010 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20307401      PMCID: PMC2864176          DOI: 10.1177/193229681000400221

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  32 in total

Review 1.  Continuous glucose monitoring: roadmap for 21st century diabetes therapy.

Authors:  David C Klonoff
Journal:  Diabetes Care       Date:  2005-05       Impact factor: 19.112

2.  Accuracy of the 5-day FreeStyle Navigator Continuous Glucose Monitoring System: comparison with frequent laboratory reference measurements.

Authors:  Richard L Weinstein; Sherwyn L Schwartz; Ronald L Brazg; Jolyon R Bugler; Thomas A Peyser; Geoffrey V McGarraugh
Journal:  Diabetes Care       Date:  2007-03-02       Impact factor: 19.112

3.  Calibration of the continuous glucose monitoring system for transient glucose monitoring.

Authors:  Leann M Lesperance; Anna Spektor; Kenneth J McLeod
Journal:  Diabetes Technol Ther       Date:  2007-04       Impact factor: 6.118

Review 4.  A tale of two compartments: interstitial versus blood glucose monitoring.

Authors:  Eda Cengiz; William V Tamborlane
Journal:  Diabetes Technol Ther       Date:  2009-06       Impact factor: 6.118

5.  Evaluating clinical accuracy of systems for self-monitoring of blood glucose.

Authors:  W L Clarke; D Cox; L A Gonder-Frederick; W Carter; S L Pohl
Journal:  Diabetes Care       Date:  1987 Sep-Oct       Impact factor: 19.112

6.  Reconstruction of glucose in plasma from interstitial fluid continuous glucose monitoring data: role of sensor calibration.

Authors:  Andrea Facchinetti; Giovanni Sparacino; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2007-09

7.  Predicting subcutaneous glucose concentration in humans: data-driven glucose modeling.

Authors:  Adiwinata Gani; Andrei V Gribok; Srinivasan Rajaraman; W Kenneth Ward; Jaques Reifman
Journal:  IEEE Trans Biomed Eng       Date:  2008-09-16       Impact factor: 4.538

8.  Modeling of Calibration Effectiveness and Blood-to-Interstitial Glucose Dynamics as Potential Confounders of the Accuracy of Continuous Glucose Sensors during Hyperinsulinemic Clamp.

Authors:  Christopher King; Stacey M Anderson; Marc Breton; William L Clarke; Boris P Kovatchev
Journal:  J Diabetes Sci Technol       Date:  2007-05

9.  Continuous glucose monitoring and intensive treatment of type 1 diabetes.

Authors:  William V Tamborlane; Roy W Beck; Bruce W Bode; Bruce Buckingham; H Peter Chase; Robert Clemons; Rosanna Fiallo-Scharer; Larry A Fox; Lisa K Gilliam; Irl B Hirsch; Elbert S Huang; Craig Kollman; Aaron J Kowalski; Lori Laffel; Jean M Lawrence; Joyce Lee; Nelly Mauras; Michael O'Grady; Katrina J Ruedy; Michael Tansey; Eva Tsalikian; Stuart Weinzimer; Darrell M Wilson; Howard Wolpert; Tim Wysocki; Dongyuan Xing
Journal:  N Engl J Med       Date:  2008-09-08       Impact factor: 91.245

10.  Comparison of accuracy and safety of the SEVEN and the Navigator continuous glucose monitoring systems.

Authors:  Satish K Garg; James Smith; Christie Beatson; Benita Lopez-Baca; Mary Voelmle; Peter A Gottlieb
Journal:  Diabetes Technol Ther       Date:  2009-02       Impact factor: 6.118

View more
  7 in total

1.  In Vitro Sugar Interference Testing With Amperometric Glucose Oxidase Sensors.

Authors:  Ryan Boehm; John Donovan; Disha Sheth; Andrew Durfor; Jason Roberts; Irada Isayeva
Journal:  J Diabetes Sci Technol       Date:  2018-08-03

2.  Real-time state estimation and long-term model adaptation: a two-sided approach toward personalized diagnosis of glucose and insulin levels.

Authors:  Claudia Eberle; Christoph Ament
Journal:  J Diabetes Sci Technol       Date:  2012-09-01

3.  Predicting Plasma Glucose From Interstitial Glucose Observations Using Bayesian Methods.

Authors:  Alexander Hildenbrand Hansen; Anne Katrine Duun-Henriksen; Rune Juhl; Signe Schmidt; Kirsten Nørgaard; John Bagterp Jørgensen; Henrik Madsen
Journal:  J Diabetes Sci Technol       Date:  2014-03-06

Review 4.  Estimating plasma glucose from interstitial glucose: the issue of calibration algorithms in commercial continuous glucose monitoring devices.

Authors:  Paolo Rossetti; Jorge Bondia; Josep Vehí; Carmine G Fanelli
Journal:  Sensors (Basel)       Date:  2010-12-03       Impact factor: 3.576

5.  Physical Activity and Psychological Stress Detection and Assessment of Their Effects on Glucose Concentration Predictions in Diabetes Management.

Authors:  Mert Sevil; Mudassir Rashid; Iman Hajizadeh; Minsun Park; Laurie Quinn; Ali Cinar
Journal:  IEEE Trans Biomed Eng       Date:  2021-06-17       Impact factor: 4.756

Review 6.  Calibration of Minimally Invasive Continuous Glucose Monitoring Sensors: State-of-The-Art and Current Perspectives.

Authors:  Giada Acciaroli; Martina Vettoretti; Andrea Facchinetti; Giovanni Sparacino
Journal:  Biosensors (Basel)       Date:  2018-03-13

7.  Noninvasive, wearable, and tunable electromagnetic multisensing system for continuous glucose monitoring, mimicking vasculature anatomy.

Authors:  Jessica Hanna; Moussa Bteich; Youssef Tawk; Ali H Ramadan; Batoul Dia; Fatima A Asadallah; Aline Eid; Rouwaida Kanj; Joseph Costantine; Assaad A Eid
Journal:  Sci Adv       Date:  2020-06-10       Impact factor: 14.136

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.