Literature DB >> 20305857

Attachment systems for mandibular single-implant overdentures: an in vitro retention force investigation on different designs.

Nabeel Alsabeeha1, Momen Atieh, Michael V Swain, Alan G T Payne.   

Abstract

PURPOSE: The aim of this study was to investigate the retentive force of six different attachment systems used for mandibular single-implant overdentures, including two prototype large ball attachment designs.
MATERIALS AND METHODS: Two prototype ball attachments of larger dimensions (7.9 and 5.9 mm) and four commercially available ball and stud attachments of standard dimensions (2.25 and 4.0 mm) were evaluated on three identical test casts resembling an edentulous mandible with severe residual ridge resorption. Five samples from each attachment system (n=30) were connected to three different implants (8.0-mm wide diameter, 3.75-mm regular diameter, and 4.0-mm regular diameter). An Instron testing machine with a computer software package was used to deliver a vertical dislodging force at a cross-head speed of 50 mm/min to each overdenture sample from the anterior direction. A total of 300 pull tests were conducted (50 per attachment system). The maximum load (retentive force) required to separate each overdenture from the supporting implant was then measured.
RESULTS: The highest retentive force (36.97+/-2.23 N) was achieved with the 7.9-mm prototype ball attachment design, followed in a decreasing order by the 5.9-mm prototype ball attachment design (32.06+/-2.59 N), the standard 2.25-mm ball attachment (17.32+/-3.68 N), Locator white (12.39+/-0.55 N), Locator pink (9.40 N+/-0.74 N), and Locator blue (3.83+/-0.64 N). A statistically significant difference (P<.0001) was found between all attachments.
CONCLUSIONS: Attachment systems of larger dimensions provided higher retentive forces for mandibular single-implant overdentures. Further in vitro and in vivo research is necessary to determine prosthodontic outcomes with these attachments in edentulous patients prior to their routine clinical use internationally.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20305857

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  10 in total

1.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

2.  Effect of attachment type on load distribution to implant abutments and the residual ridge in mandibular implant-supported overdentures.

Authors:  Nobuhiro Yoda; Yoshiki Matsudate; Masaru Abue; Guang Hong; Keiichi Sasaki
Journal:  J Dent Biomech       Date:  2015-03-16

Review 3.  Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems.

Authors:  Elie E Daou
Journal:  J Int Soc Prev Community Dent       Date:  2015 Jul-Aug

4.  Microbiological evaluation of LOCATOR® Legacy attachments: A cross-sectional clinical study.

Authors:  Ursina Nagy; Christophe Guédat; Catherine Giannopoulou; Martin Schimmel; Frauke Müller; Murali Srinivasan
Journal:  Clin Exp Dent Res       Date:  2019-07-18

5.  How the initial retentive force of implant-supported overdentures can be affected with splinted and unsplinted attachments systems.

Authors:  Farahnaz Nejatidanesh; Omid Savabi; Ghazal Savabi; Mehdi Razavi
Journal:  Dent Res J (Isfahan)       Date:  2021-12-10

Review 6.  Evaluation of Retention, Wear, and Maintenance of Attachment Systems for Single- or Two-Implant-Retained Mandibular Overdentures: A Systematic Review.

Authors:  Raphaël Wakam; Aurélie Benoit; Kwamivi Bernardin Mawussi; Caroline Gorin
Journal:  Materials (Basel)       Date:  2022-03-04       Impact factor: 3.623

7.  Single implant supported mandibular overdenture: A literature review.

Authors:  Sudhindra Mahoorkar; Srinidhi Bhat; Radhika Kant
Journal:  J Indian Prosthodont Soc       Date:  2016 Jan-Mar

8.  Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro study.

Authors:  Moustafa Abdou Elsyad; Fathi Abo Setta; Ahmed Samir Khirallah
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

9.  Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study.

Authors:  Carlos Aroso; Antonio Sergio Silva; Raul Ustrell; Jose Manuel Mendes; Ana Cristina Braga; Esther Berastegui; Tomas Escuin
Journal:  J Adv Prosthodont       Date:  2016-02-23       Impact factor: 1.904

10.  In vitro retention capacity of two overdenture attachment systems: Locator® and Equator®.

Authors:  Nieves Mínguez-Tomás; Jorge Alonso-Pérez-Barquero; Lucía Fernández-Estevan; Ángel Vicente-Escuder; Eduardo J Selva-Otaolaurruchi
Journal:  J Clin Exp Dent       Date:  2018-07-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.