Literature DB >> 20305793

Detection of Radiation-Exposure Biomarkers by Differential Mobility Prefiltered Mass Spectrometry (DMS-MS).

Stephen L Coy1, Evgeny V Krylov, Bradley B Schneider, Thomas R Covey, David J Brenner, John B Tyburski, Andrew D Patterson, Kris W Krausz, Albert J Fornace, Erkinjon G Nazarov.   

Abstract

Technology to enable rapid screening for radiation exposure has been identified as an important need, and, as a part of a NIH / NIAD effort in this direction, metabolomic biomarkers for radiation exposure have been identified in a recent series of papers. To reduce the time necessary to detect and measure these biomarkers, differential mobility spectrometry - mass spectrometry (DMS-MS) systems have been developed and tested. Differential mobility ion filters preselect specific ions and also suppress chemical noise created in typical atmospheric-pressure ionization sources (ESI, MALDI, and others). Differential-mobility-based ion selection is based on the field dependence of ion mobility, which, in turn, depends on ion characteristics that include conformation, charge distribution, molecular polarizability, and other properties, and on the transport gas composition which can be modified to enhance resolution. DMS-MS is able to resolve small-molecule biomarkers from nearly-isobaric interferences, and suppresses chemical noise generated in the ion source and in the mass spectrometer, improving selectivity and quantitative accuracy. Our planar DMS design is rapid, operating in a few milliseconds, and analyzes ions before fragmentation. Depending on MS inlet conditions, DMS-selected ions can be dissociated in the MS inlet expansion, before mass analysis, providing a capability similar to MS/MS with simpler instrumentation. This report presents selected DMS-MS experimental results, including resolution of complex test mixtures of isobaric compounds, separation of charge states, separation of isobaric biomarkers (citrate and isocitrate), and separation of nearly-isobaric biomarker anions in direct analysis of a bio-fluid sample from the radiation-treated group of a mouse-model study. These uses of DMS combined with moderate resolution MS instrumentation indicate the feasibility of field-deployable instrumentation for biomarker evaluation.

Entities:  

Year:  2010        PMID: 20305793      PMCID: PMC2841297          DOI: 10.1016/j.ijms.2010.01.013

Source DB:  PubMed          Journal:  Int J Mass Spectrom        ISSN: 1387-3806            Impact factor:   1.986


  19 in total

1.  Mechanistic investigation of ionization suppression in electrospray ionization.

Authors:  R King; R Bonfiglio; C Fernandez-Metzler; C Miller-Stein; T Olah
Journal:  J Am Soc Mass Spectrom       Date:  2000-11       Impact factor: 3.109

2.  Separation of ions from explosives in differential mobility spectrometry by vapor-modified drift gas.

Authors:  G A Eiceman; E V Krylov; N S Krylova; E G Nazarov; R A Miller
Journal:  Anal Chem       Date:  2004-09-01       Impact factor: 6.986

Review 3.  Priority list of research areas for radiological nuclear threat countermeasures.

Authors:  Terry C Pellmar; Sara Rockwell
Journal:  Radiat Res       Date:  2005-01       Impact factor: 2.841

4.  Rapid separation and quantitative analysis of peptides using a new nanoelectrospray- differential mobility spectrometer-mass spectrometer system.

Authors:  Daren S Levin; Raanan A Miller; Erkinjon G Nazarov; Paul Vouros
Journal:  Anal Chem       Date:  2006-08-01       Impact factor: 6.986

5.  Review of applications of high-field asymmetric waveform ion mobility spectrometry (FAIMS) and differential mobility spectrometry (DMS).

Authors:  Beata M Kolakowski; Zoltán Mester
Journal:  Analyst       Date:  2007-06-26       Impact factor: 4.616

6.  UPLC-ESI-TOFMS-based metabolomics and gene expression dynamics inspector self-organizing metabolomic maps as tools for understanding the cellular response to ionizing radiation.

Authors:  Andrew D Patterson; Henghong Li; Gabriel S Eichler; Kristopher W Krausz; John N Weinstein; Albert J Fornace; Frank J Gonzalez; Jeffrey R Idle
Journal:  Anal Chem       Date:  2008-01-04       Impact factor: 6.986

7.  Radiation metabolomics. 3. Biomarker discovery in the urine of gamma-irradiated rats using a simplified metabolomics protocol of gas chromatography-mass spectrometry combined with random forests machine learning algorithm.

Authors:  Christian Lanz; Andrew D Patterson; Josef Slavík; Kristopher W Krausz; Monika Ledermann; Frank J Gonzalez; Jeffrey R Idle
Journal:  Radiat Res       Date:  2009-08       Impact factor: 2.841

8.  Miniature differential mobility spectrometry using atmospheric pressure photoionization.

Authors:  Erkinjon G Nazarov; Raanan A Miller; Gary A Eiceman; John A Stone
Journal:  Anal Chem       Date:  2006-07-01       Impact factor: 6.986

9.  Using a nanoelectrospray-differential mobility spectrometer-mass spectrometer system for the analysis of oligosaccharides with solvent selected control over ESI aggregate ion formation.

Authors:  Daren S Levin; Paul Vouros; Raanan A Miller; Erkinjon G Nazarov
Journal:  J Am Soc Mass Spectrom       Date:  2006-11-30       Impact factor: 3.109

10.  Diagnostic and therapeutic implications of medium-chain acylcarnitines in the medium-chain acyl-coA dehydrogenase deficiency.

Authors:  C R Roe; D S Millington; D A Maltby; T P Bohan; S G Kahler; R A Chalmers
Journal:  Pediatr Res       Date:  1985-05       Impact factor: 3.756

View more
  19 in total

1.  Rapid and High-Throughput Detection and Quantitation of Radiation Biomarkers in Human and Nonhuman Primates by Differential Mobility Spectrometry-Mass Spectrometry.

Authors:  Zhidan Chen; Stephen L Coy; Evan L Pannkuk; Evagelia C Laiakis; Adam B Hall; Albert J Fornace; Paul Vouros
Journal:  J Am Soc Mass Spectrom       Date:  2016-07-08       Impact factor: 3.109

2.  Differential mobility spectrometry: a valuable technology for analyzing challenging biological samples.

Authors:  J Larry Campbell; J C Yves Le Blanc; Richard G Kibbey
Journal:  Bioanalysis       Date:  2015       Impact factor: 2.681

3.  Predicting compensation voltage for singly-charged ions in high-field asymmetric waveform ion mobility spectrometry (FAIMS).

Authors:  Alexander A Aksenov; James Kapron; Cristina E Davis
Journal:  J Am Soc Mass Spectrom       Date:  2012-08-08       Impact factor: 3.109

Review 4.  Metabolomic applications in radiation biodosimetry: exploring radiation effects through small molecules.

Authors:  Evan L Pannkuk; Albert J Fornace; Evagelia C Laiakis
Journal:  Int J Radiat Biol       Date:  2017-01-12       Impact factor: 2.694

5.  Multi-component ion modifiers and arcing suppressants to enhance differential mobility spectrometry for separation of peptides and drug molecules.

Authors:  Voislav Blagojevic; Gregory K Koyanagi; Diethard K Bohme
Journal:  J Am Soc Mass Spectrom       Date:  2014-01-15       Impact factor: 3.109

6.  Understanding gas phase modifier interactions in rapid analysis by differential mobility-tandem mass spectrometry.

Authors:  Amol Kafle; Stephen L Coy; Bryan M Wong; Albert J Fornace; James J Glick; Paul Vouros
Journal:  J Am Soc Mass Spectrom       Date:  2014-01-23       Impact factor: 3.109

7.  Description of gas-phase ion/neutral interactions in differential ion mobility spectrometry: CV prediction using calibration runs.

Authors:  David Auerbach; Julia Aspenleiter; Dietrich A Volmer
Journal:  J Am Soc Mass Spectrom       Date:  2014-06-14       Impact factor: 3.109

8.  Differential mobility spectrometry (DMS) reveals the elevation of urinary acetylcarnitine in non-human primates (NHPs) exposed to radiation.

Authors:  Nicholas B Vera; Zhidan Chen; Evan Pannkuk; Evagelia C Laiakis; Albert J Fornace; Derek M Erion; Stephen L Coy; Jeffrey A Pfefferkorn; Paul Vouros
Journal:  J Mass Spectrom       Date:  2018-07       Impact factor: 1.982

9.  Extending the dynamic range of the ion trap by differential mobility filtration.

Authors:  Adam B Hall; Stephen L Coy; Amol Kafle; James Glick; Erkinjon Nazarov; Paul Vouros
Journal:  J Am Soc Mass Spectrom       Date:  2013-09       Impact factor: 3.109

10.  Quantitation of Urinary Acylcarnitines by DMS-MS/MS Uncovers the Effects of Total Body Irradiation in Cancer Patients.

Authors:  Nicholas B Vera; Stephen L Coy; Evagelia C Laiakis; Albert J Fornace; Michelle Clasquin; Christopher A Barker; Jeffrey A Pfefferkorn; Paul Vouros
Journal:  J Am Soc Mass Spectrom       Date:  2020-01-28       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.