Literature DB >> 2028344

Posterior cervical arthrodesis with AO reconstruction plates and bone graft.

P A Anderson1, M B Henley, M S Grady, P X Montesano, H R Winn.   

Abstract

The efficacy of posterior arthrodesis of the cervical spine with AO reconstruction plates and autogenous bone graft was evaluated in a prospective study. The technique of surgical exposure and the application of the reconstruction plates fixed with screws to the lateral masses is described in detail. Of 30 patients with unstable cervical spines, all had solid fusions based on flexion and extension radiographs at follow-up averaging 17.8 months. No patient's neurologic function deteriorated. All incomplete spinal cord injuries improved at least one Frankel level. There were no neurologic or vascular complications. At follow-up, three patients had fusions extending one level longer than those instrumented. Three other patients had an increase in kyphosis compared with the operative reduction, which was not clinically significant. Although a single screw loosened in three other patients, none had an increased deformity, and all progressed to successful arthrodesis. This technique is particularly advantageous when spinous processes, laminas, and facets are injured or deficient, or when facet-type fusions are indicated.

Entities:  

Mesh:

Year:  1991        PMID: 2028344     DOI: 10.1097/00007632-199103001-00012

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  42 in total

1.  Is intraoperative CT of posterior cervical spine instrumentation cost-effective and does it reduce complications?

Authors:  Andrew C Hecht; Steven M Koehler; Janelle C Laudone; Arthur Jenkins; Sheeraz Qureshi
Journal:  Clin Orthop Relat Res       Date:  2011-04       Impact factor: 4.176

2.  Freehand determination of the trajectory angle for cervical lateral mass screws: how accurate is it?

Authors:  Debasish Pal; Edward Bayley; Sani A Magaji; Bronek M Boszczyk
Journal:  Eur Spine J       Date:  2011-01-29       Impact factor: 3.134

3.  Laminoplasty using Twinfix suture anchors to maintain cervical canal expansion.

Authors:  Hai-Long Yu; Liang-Bi Xiang; Jun Liu; Yu Chen; Ming Yu; Yan Cao
Journal:  Eur Spine J       Date:  2010-05-07       Impact factor: 3.134

4.  Comparative analysis of three different cervical lateral mass screw fixation techniques by complications and bicortical purchase : cadaveric study.

Authors:  Jin-Wook Baek; Dong-Mook Park; Dae-Hyun Kim
Journal:  J Korean Neurosurg Soc       Date:  2010-09-30

5.  An analysis of the anatomic features of the cervical spine using computed tomography to select safer screw insertion techniques.

Authors:  Masahiro Nishinome; Haku Iizuka; Yoichi Iizuka; Kenji Takagishi
Journal:  Eur Spine J       Date:  2013-07-06       Impact factor: 3.134

6.  Posterior spinal fusion of the cervical spine using the Alligator plate: operative technique and clinical results.

Authors:  T Fuji; M Tanaka; S Hirota; K Masuhara; T Mitsuoka; H Hamada
Journal:  Eur Spine J       Date:  1993-10       Impact factor: 3.134

7.  Anatomy of subaxial cervical foramens: the safety zone for lateral mass screwing.

Authors:  Masahiro Nishinome; Haku Iizuka; Yoichi Iizuka; Kenji Takagishi
Journal:  Eur Spine J       Date:  2011-08-26       Impact factor: 3.134

8.  Letter to the Editor concerning "Proposal for a new trajectory for subaxial cervical lateral mass screws" by S. Amhaz-Escanlar et al. (Eur Spine J; 2018: doi:10.1007/s00586-018-5670-5).

Authors:  Gaston Camino Willhuber
Journal:  Eur Spine J       Date:  2018-08-04       Impact factor: 3.134

9.  Posterior stabilization of cervical spine injuries using the Roy-Camille plates: a long-term follow-up.

Authors:  Demitrios Korres; Vassilios S Nikolaou; Maria Kaseta; Demetrios Evangelopoulos; Kostas Markatos; John Lazarettos; Nicolas Efstathopoulos
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-12-10

10.  Early results from posterior cervical fusion with a screw-rod system.

Authors:  Sang Hyun Kim; Dong Ah Shin; Seung Yi; Do Heum Yoon; Keung Nyun Kim; Hyun Chul Shin
Journal:  Yonsei Med J       Date:  2007-06-30       Impact factor: 2.759

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.