Performance evaluation of the body fluid mode on the platform Sysmex XE-5000 series automated hematology analyzer.

A Paris1, T Nhan, E Cornet, J-P Perol, M Malet, X Troussard.   

Abstract

We evaluated the performance of the automated body fluid mode of the Sysmex XE-5000 series automated haematology analyzer and compared the performance of the automated method for obtaining white blood cell (WBC), red blood cell (RBC) counts and WBC differential counts with microscopic method. One hundred and seventy-four samples were analysed: 81 ascitic fluid, 32 cerebrospinal fluid (CSF), 26 pleural fluid (PF), 18 synovial fluid (SF), 13 peritoneal fluid (PeF) and 4 other types. The agreement between the automated method and the manual reference showed high correlation, with Pearson correlation coefficients greater than 0.9 for all types of body fluids. We also demonstrate that the automated body fluid analysis on the XE-5000 is an acceptable alternative to the microscopic reference method as far as ascitic fluid, peritoneal dialysis fluid, SF or PF are concerned. Conversely, results for body fluid samples from oncology patients with leukaemia or tumours showed significant differences between both methods, as XE-5000 counted blast cells and neoplastic cells in mononuclear cell count. XE-5000 could represent an attractive method for the automated analysis of WBC, RBC, mononuclear cell count (MNC) and polymorphonuclear (PMN) cells of most body fluids. However, CSFs from patients with leukaemia or lymphoma should be processed with the microscopic reference method in order to detect abnormal leukaemic cells.

Entities:  

Mesh:

Year:  2010        PMID: 20236183     DOI: 10.1111/j.1751-553X.2010.01220.x

Source DB:  PubMed          Journal:  Int J Lab Hematol        ISSN: 1751-5521            Impact factor:   2.877


  9 in total

1.  Extent of agreement between the body fluid model of Sysmex XN-20 and the manual microscopy method.

Authors:  Wei-Hua Huang; Lin-Peng Lu; Kang Wu; Fang-Yu Guo; Jie Guo; Jing-Long Yu; Dao-Yin Zhou; Yi Sun; An-Mei Deng
Journal:  J Clin Lab Anal       Date:  2016-12-07       Impact factor: 2.352

2.  Continuous ambulatory peritoneal dialysis, ascitic and pleural body fluids evaluation with the Mindray BC-6800 hematology analyzer.

Authors:  Oscar Fuster; Belinda Andino; Amparo Pardo; Begoña Laiz
Journal:  J Clin Lab Anal       Date:  2017-04-26       Impact factor: 2.352

3.  Automated analysis for differentiating leukocytes in body fluids using the software "biological liquid application" on ADVIA2120/2120i hematology analyzer.

Authors:  Alessandra Falda; Paolo Doretto
Journal:  J Clin Lab Anal       Date:  2018-05-25       Impact factor: 2.352

4.  What Is the Impact of Automated Synovial Cell Counting on Different Aseptic Causes and Periprosthetic Conditions Associated With Revision THA?

Authors:  Hussein Abdelaziz; Alaa Aljawabra; Markus Rossmann; Calvin Shum Tien; Mustafa Citak; Till Orla Klatte; Thorsten Gehrke
Journal:  Clin Orthop Relat Res       Date:  2021-12-01       Impact factor: 4.176

5.  Use of the Sysmex XT-4000i hematology analyzer in the differentiation of cerebrospinal fluid cells in children.

Authors:  Beata Zelazowska-Rutkowska; Janusz Zak; Malgorzata Wojtkowska; Justyna Zaworonek; Bogdan Cylwik
Journal:  J Clin Lab Anal       Date:  2018-11-28       Impact factor: 2.352

6.  Diagnosis of a T-lineage acute lymphoblastic leukemia through digitalized cell analysis of the pleural effusion.

Authors:  Benedetta Peruzzi; Ilaria Cutini; Anna Maria Grazia Gelli; Tommaso Rondelli; Marinella Statello; Sara Bencini; Francesco Mannelli; Roberto Caporale; Alberto Bosi; Alessandra Fanelli
Journal:  Int Med Case Rep J       Date:  2013-11-01

7.  Effect of sample processing and time delay on cell count and chemistry tests in cerebrospinal fluid collected from drainage systems.

Authors:  Ana Mlinarić; Željka Vogrinc; Zrinka Drenšek
Journal:  Biochem Med (Zagreb)       Date:  2018-10-15       Impact factor: 2.313

8.  A comparison of the analysis of 3 types of body fluids using the XN-350 hematology analyzer versus light microscopy assessment.

Authors:  Jiwon Lee; Younggeun Cho; Han-Sung Kim; Hee Jung Kang; Miyoung Kim; Young Kyung Lee
Journal:  Medicine (Baltimore)       Date:  2021-03-19       Impact factor: 1.817

9.  Evaluation of cell count and classification capabilities in body fluids using a fully automated Sysmex XN equipped with high-sensitive Analysis (hsA) mode and DI-60 hematology analyzer system.

Authors:  Hiroyuki Takemura; Tomohiko Ai; Konobu Kimura; Kaori Nagasaka; Toshihiro Takahashi; Koji Tsuchiya; Haeun Yang; Aya Konishi; Kinya Uchihashi; Takashi Horii; Yoko Tabe; Akimichi Ohsaka
Journal:  PLoS One       Date:  2018-04-26       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.