BACKGROUND: Monoaxial and polyaxial screw insertion are used in angular stable plating of displaced proximal humeral fractures. Aim of the study was to compare both fixation techniques by radiographic evaluation.
METHODS: Prospective randomized treatment with monoaxial or polyaxial screw insertion in angular stable anatomic preshaped plates of displaced proximal humeral fractures. Analysis of standardized true anterior-posterior (true a.p.) and outlet-view radiographs at 1 day, 6 weeks, 3 months, and 6 months after surgery by two radiologists with respect to radiographic evidence of secondary varus displacement, cut out of screws, osteonecrosis, and hardware failure. Secondary varus displacement was defined as a varus decrease of the humeral head-shaft angle of > 10 degree in true a.p. radiographs.
RESULTS: Sixty-six consecutive patients (48 women, [72.7%]; 18 men, [27.3%]; mean age 67.7 years [95% CI, 63.9-71.6]) with displaced proximal humeral fractures were evaluated in this study. Nineteen patients (29%) showed secondary varus displacement of > 10-degree angle. In 6 cases (9%), intra-articular cut out of screws was found. Furthermore, 1 case (2%) of nonunion was observed. No relationship between monoaxial and polyaxial screw insertion was found regarding occurrence of secondary varus displacement (monoaxial, 11/polyaxial, 8; p = 0.91) or screw cut out (monoaxial, 4/polyaxial, 2; p = 0.64). Prevalence of secondary varus displacement and hardware cut out was related to patients age (p = 0.02) and fracture pattern, according to Neer- and AO/OTA-classification (p < 0.001). The average immediate postoperative head-shaft angle was 135.2 degrees (CI, 132.3-138.1) in the group without radiographic complication, compared with 126.7-degree angle (CI, 123.6-129.7) among those with secondary varus displacement of > 10-degree angle and screw cut out (p < 0.001). Furthermore, in cases of an immediate postoperative head-shaft angle of < 130 degrees, there was a 48% incidence of secondary varus dislocation (n = 13) versus 15% in cases with a head-shaft angle > 130 degrees (n = 6, p = 0.004).
CONCLUSION: Monoaxial and polyaxial screw insertion allow for mechanical stabilization in angular stable plating of unstable proximal humerus fractures. Radiographic evidence of secondary varus displacement of > 10-degree angle and screw cut out was seen similarly often in both fixation techniques. To avoid secondary varus displacement and screw cut out, restoration of a humeral head-shaft angle of > 130 degrees seems to be important in monoaxial and polyaxial fixation of proximal humeral fractures.

Entities:  

Mesh:

Year:  2010        PMID: 20234324     DOI: 10.1097/TA.0b013e3181c9b8a7

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  16 in total

1.  [Mono- versus polyaxial locking plates].

Authors:  M Hanschen; P Biberthaler
Journal:  Unfallchirurg       Date:  2013-08       Impact factor: 1.000

2.  The Treatment of Proximal Humerus Fracture Using Internal Fixation with Fixed-angle Plates.

Authors:  Patrick Ziegler; Sven Maier; Ulrich Stöckle; Markus Gühring; Fabian M Stuby
Journal:  Dtsch Arztebl Int       Date:  2019-11-08       Impact factor: 5.594

3.  Position of polyaxial versus monoaxial screws in locked plating for proximal humeral fractures: analysis of a prospective randomized study.

Authors:  Ben Ockert; Vera Pedersen; Lucas Geyer; Stefan Wirth; Wolf Mutschler; Stefan Grote
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-11-20

Review 4.  Interventions for treating proximal humeral fractures in adults.

Authors:  Helen Hg Handoll; Joanne Elliott; Theis M Thillemann; Patricia Aluko; Stig Brorson
Journal:  Cochrane Database Syst Rev       Date:  2022-06-21

5.  Mono- versus polyaxial locking plates in distal femur fractures: a prospective randomized multicentre clinical trial.

Authors:  Marc Hanschen; Ina M Aschenbrenner; Kai Fehske; Sonja Kirchhoff; Leonhard Keil; Boris M Holzapfel; Sebastian Winkler; Bernd Fuechtmeier; Rainer Neugebauer; Sven Luehrs; Ulrich Liener; Peter Biberthaler
Journal:  Int Orthop       Date:  2013-12-11       Impact factor: 3.075

6.  Open reduction internal fixation of proximal humerus fractures.

Authors:  Marschall B Berkes; Milton T M Little; Dean G Lorich
Journal:  Curr Rev Musculoskelet Med       Date:  2013-03

7.  Safety and feasibility of cell-based therapy of autologous bone marrow-derived mononuclear cells in plate-stabilized proximal humeral fractures in humans.

Authors:  Caroline Seebach; Dirk Henrich; Simon Meier; Christoph Nau; Halvard Bonig; Ingo Marzi
Journal:  J Transl Med       Date:  2016-11-15       Impact factor: 5.531

8.  Additional calcar support using a blade device reduces secondary varus displacement following reconstruction of the proximal humerus: a prospective study.

Authors:  Marc Beirer; Moritz Crönlein; Arne J Venjakob; Tim Saier; Marcus Schmitt-Sody; Stefan Huber-Wagner; Peter Biberthaler; Chlodwig Kirchhoff
Journal:  Eur J Med Res       Date:  2015-10-07       Impact factor: 2.175

9.  Is loss of fixation following locked plating of proximal humeral fractures related to the number of screws and their positions in the humeral head?

Authors:  Mohammad Maddah; Wolf C Prall; Lucas Geyer; Stefan Wirth; Wolf Mutschler; Ben Ockert
Journal:  Orthop Rev (Pavia)       Date:  2014-06-24

10.  Histomorphometric Assessment of Cancellous and Cortical Bone Material Distribution in the Proximal Humerus of Normal and Osteoporotic Individuals: Significantly Reduced Bone Stock in the Metaphyseal and Subcapital Regions of Osteoporotic Individuals.

Authors:  Christoph M Sprecher; Florian Schmidutz; Tobias Helfen; R Geoff Richards; Michael Blauth; Stefan Milz
Journal:  Medicine (Baltimore)       Date:  2015-12       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.