Patrick Ziegler1, Sven Maier, Ulrich Stöckle, Markus Gühring, Fabian M Stuby. 1. BG Hospital Tübingen, University Clinic for Trauma and Reconstructive Surgery, University of Tübingen, Germany; Center for Musculoskeletal Surgery, Charité University Medical Center Berlin, Germany; Center for Bone and Joint Surgery, Kronprinzenbau Hospital, Reutlingen, Germany; BG Hospital Murnau, Murnau, Germany.
Abstract
BACKGROUND: Implants made of various types of material can be used for the internal fixation of fractures. Carbon fiber reinforced polyetheretherketone (CFR-PEEK) is a radiolucent material that may have advantageous handling properties compared with titanium implants. METHODS:Seventy-six patients with proximal humerus fractures requiring surgery were randomized to receive a fixed-angle plate made out of either titanium or CFR- PEEK. To measure the functional outcome, the DASH score (Disabilities of Arm, Shoulder, and Hand; primary endpoint), the Simple Shoulder Test (SST), and the Oxford Shoulder Score (OSS) were determined in 63 patients at 6 weeks, 12 weeks, and 6 months after surgery, accompanied at each time point by radiological evaluation. RESULTS: Both groups displayed improvement in DASH scores 6 months after surgery (CFR-PEEK: 27.5 ± 20.5; titanium: 28.5 ± 17.9; p = 0.82). Sensitivity analysis with multiple imputations confirmed this result (27.4 ± 19.2 versus 28.5 ± 16.6). The OSS and SST scores were likewise improved in both groups. All patients displayed full bony consolidation 12 weeks after surgery. In no case was material failure, secondary dislocation, or screw perforation seen. No difference was seen in the maintenance of postoperative reposition between the CFR-PEEK group and the titanium group. CONCLUSION: The internal fixation of proximal humerus fractures with either CFR-PEEK or titanium led to clinical improvement 6 months after surgery. No clinical or radiological difference in outcomes was seen between the two groups. Because of the study design, however, the equivalence of the two interventions was not con- clusively demonstrated; a non-inferiority study would have been needed for this purpose.
RCT Entities:
BACKGROUND: Implants made of various types of material can be used for the internal fixation of fractures. Carbon fiber reinforced polyetheretherketone (CFR-PEEK) is a radiolucent material that may have advantageous handling properties compared with titanium implants. METHODS: Seventy-six patients with proximal humerus fractures requiring surgery were randomized to receive a fixed-angle plate made out of either titanium or CFR- PEEK. To measure the functional outcome, the DASH score (Disabilities of Arm, Shoulder, and Hand; primary endpoint), the Simple Shoulder Test (SST), and the Oxford Shoulder Score (OSS) were determined in 63 patients at 6 weeks, 12 weeks, and 6 months after surgery, accompanied at each time point by radiological evaluation. RESULTS: Both groups displayed improvement in DASH scores 6 months after surgery (CFR-PEEK: 27.5 ± 20.5; titanium: 28.5 ± 17.9; p = 0.82). Sensitivity analysis with multiple imputations confirmed this result (27.4 ± 19.2 versus 28.5 ± 16.6). The OSS and SST scores were likewise improved in both groups. All patients displayed full bony consolidation 12 weeks after surgery. In no case was material failure, secondary dislocation, or screw perforation seen. No difference was seen in the maintenance of postoperative reposition between the CFR-PEEK group and the titanium group. CONCLUSION: The internal fixation of proximal humerus fractures with either CFR-PEEK or titanium led to clinical improvement 6 months after surgery. No clinical or radiological difference in outcomes was seen between the two groups. Because of the study design, however, the equivalence of the two interventions was not con- clusively demonstrated; a non-inferiority study would have been needed for this purpose.
Authors: R Rotini; M Cavaciocchi; D Fabbri; G Bettelli; F Catani; G Campochiaro; M Fontana; A Colozza; C F De Biase; G Ziveri; C Zapparoli; F Stacca; R Lupo; S Rapisarda; E Guerra Journal: Musculoskelet Surg Date: 2015-05-12
Authors: John-Erik Bell; Brian C Leung; Kevin F Spratt; Ken J Koval; James D Weinstein; David C Goodman; Anna N A Tosteson Journal: J Bone Joint Surg Am Date: 2011-01-19 Impact factor: 5.284
Authors: Michael J Gardner; Yoram Weil; Joseph U Barker; Bryan T Kelly; David L Helfet; Dean G Lorich Journal: J Orthop Trauma Date: 2007-03 Impact factor: 2.512
Authors: Felix Brunner; Christoph Sommer; Christian Bahrs; Rainer Heuwinkel; Christian Hafner; Paavo Rillmann; Georges Kohut; Anders Ekelund; Mathias Muller; Laurent Audigé; Reto Babst Journal: J Orthop Trauma Date: 2009-03 Impact factor: 2.512
Authors: Brent A Ponce; Kevin J Thompson; Parthasarathy Raghava; Alan W Eberhardt; Janet P Tate; David A Volgas; James P Stannard Journal: J Bone Joint Surg Am Date: 2013-08-21 Impact factor: 5.284
Authors: Rony-Orijit Dey Hazra; Karol Szewczyk; Alexander Ellwein; Robert Blach; Gunnar Jensen; Andreas Kühnapfel; Helmut Lill; Mara Warnhoff Journal: Eur J Orthop Surg Traumatol Date: 2022-05-27
Authors: George D Chloros; Apostolos D Prodromidis; Jo Wilson; Peter V Giannoudis Journal: Eur J Trauma Emerg Surg Date: 2021-09-06 Impact factor: 2.374
Authors: Rony-Orijit Dey Hazra; Johanna Illner; Karol Szewczyk; Mara Warnhoff; Alexander Ellwein; Robert Maximillian Blach; Helmut Lill; Gunnar Jensen Journal: J Clin Med Date: 2022-01-14 Impact factor: 4.241