AIMS: To evaluate the outcome of transapical aortic valve implantation (TA-AVI) in comparison to conventional surgery. METHODS AND RESULTS: One hundred consecutive high-risk patients with symptomatic aortic valve stenosis received TA-AVI using the Edwards SAPIEN pericardial xenograft between February 2006 and January 2008. Patient age was 82.7 +/- 5 years, 77 were females, logistic EuroSCORE predicted risk of mortality was 29.4 +/- 13% and Society Thoracic Surgeons score risk for mortality was 15.2 +/- 8.3%. Propensity score analysis was used to identify a control group of patients that underwent conventional aortic valve replacement (C-AVR). Transapical aortic valve implantation was performed successfully in 97 patients, whereas three patients required early conversion. There were no new onset neurological events in the TA-AVI group and early extubation was performed in 82 patients. Echocardiography revealed good valve function with low transvalvular gradients in all patients. Thirty-day survival was 90 +/- 3 vs. 85 +/- 4% for TA-AVI vs. C-AVR, and 1-year survival was 73 +/- 4 vs. 69 +/- 5% (P = 0.55). CONCLUSION: Transapical aortic valve implantation is a safe, minimally invasive, and off-pump technique to treat high-risk patients with aortic stenosis. Results of the initial 100 patients are good and compare favourably to conventional surgery.
AIMS: To evaluate the outcome of transapical aortic valve implantation (TA-AVI) in comparison to conventional surgery. METHODS AND RESULTS: One hundred consecutive high-risk patients with symptomatic aortic valve stenosis received TA-AVI using the Edwards SAPIEN pericardial xenograft between February 2006 and January 2008. Patient age was 82.7 +/- 5 years, 77 were females, logistic EuroSCORE predicted risk of mortality was 29.4 +/- 13% and Society Thoracic Surgeons score risk for mortality was 15.2 +/- 8.3%. Propensity score analysis was used to identify a control group of patients that underwent conventional aortic valve replacement (C-AVR). Transapical aortic valve implantation was performed successfully in 97 patients, whereas three patients required early conversion. There were no new onset neurological events in the TA-AVI group and early extubation was performed in 82 patients. Echocardiography revealed good valve function with low transvalvular gradients in all patients. Thirty-day survival was 90 +/- 3 vs. 85 +/- 4% for TA-AVI vs. C-AVR, and 1-year survival was 73 +/- 4 vs. 69 +/- 5% (P = 0.55). CONCLUSION: Transapical aortic valve implantation is a safe, minimally invasive, and off-pump technique to treat high-risk patients with aortic stenosis. Results of the initial 100 patients are good and compare favourably to conventional surgery.
Authors: Solomon J Sager; Abdulla A Damluji; Joshua A Cohen; Sachil Shah; Brian P O'Neill; Carlos E Alfonso; Claudia A Martinez; Robert J Myerburg; Alan W Heldman; Mauricio G Cohen; Donald B Williams; Roger G Carrillo Journal: J Interv Card Electrophysiol Date: 2016-05-28 Impact factor: 1.900
Authors: Martin Glöckler; Andreas Koch; Verena Greim; Amira Shabaiek; Andrè Rüffer; Robert Cesnjevar; Stephan Achenbach; Sven Dittrich Journal: Eur Radiol Date: 2011-07-28 Impact factor: 5.315