BACKGROUND: The goal of this study was to evaluate high-field open magnetic resonance imaging (MRI) for intraoperative real-time imaging during hand-assisted laparoscopic liver resection. MR guidance has several advantages compared to ultrasound and may represent a future technique for abdominal surgery. Various MRI-safe and -compatible instruments were developed, tested, and applied to realize minimally invasive liver surgery under MR guidance. As proof of the concept, liver resection was performed in a porcine model. METHODS: All procedures were conducted in a 1.0-T open MRI unit. Imaging quality and surgical results were documented during three cadaveric and two live animal procedures. A nonferromagnetic hand port was used for manual access and the liver tissue was dissected using a Nd:YAG laser. RESULTS: The intervention time ranged from 126 to 145 min, with a dissection time from 11 to 15 min. Both live animals survived the intervention with a blood loss of 250 and 170 ml and a specimen weight of 138 and 177 g. A dynamic T2W fast spin-echo sequence allowed real-time imaging (1.5 s/image) with good delineation of major and small hepatic vessels. The newly developed MR-compatible instruments and camera system caused only minor interferences and artifacts of the MR image. CONCLUSION: MR-guided liver resection is feasible and provides additional image information to the surgeon. We conclude that MR-guided laparoscopic liver resection improves the anatomical orientation and may increase the safety of future minimally invasive liver surgery.
BACKGROUND: The goal of this study was to evaluate high-field open magnetic resonance imaging (MRI) for intraoperative real-time imaging during hand-assisted laparoscopic liver resection. MR guidance has several advantages compared to ultrasound and may represent a future technique for abdominal surgery. Various MRI-safe and -compatible instruments were developed, tested, and applied to realize minimally invasive liver surgery under MR guidance. As proof of the concept, liver resection was performed in a porcine model. METHODS: All procedures were conducted in a 1.0-T open MRI unit. Imaging quality and surgical results were documented during three cadaveric and two live animal procedures. A nonferromagnetic hand port was used for manual access and the liver tissue was dissected using a Nd:YAG laser. RESULTS: The intervention time ranged from 126 to 145 min, with a dissection time from 11 to 15 min. Both live animals survived the intervention with a blood loss of 250 and 170 ml and a specimen weight of 138 and 177 g. A dynamic T2W fast spin-echo sequence allowed real-time imaging (1.5 s/image) with good delineation of major and small hepatic vessels. The newly developed MR-compatible instruments and camera system caused only minor interferences and artifacts of the MR image. CONCLUSION: MR-guided liver resection is feasible and provides additional image information to the surgeon. We conclude that MR-guided laparoscopic liver resection improves the anatomical orientation and may increase the safety of future minimally invasive liver surgery.
Authors: David M Cash; Michael I Miga; Sean C Glasgow; Benoit M Dawant; Logan W Clements; Zhujiang Cao; Robert L Galloway; William C Chapman Journal: J Gastrointest Surg Date: 2007-07 Impact factor: 3.452
Authors: S S Chopra; J Rump; S C Schmidt; F Streitparth; C Seebauer; G Schumacher; I Van der Voort; U Teichgräber Journal: Eur Radiol Date: 2009-04-07 Impact factor: 5.315
Authors: Lei Feng; Charles L Dumoulin; Stephen Dashnaw; Robert D Darrow; Robert L Delapaz; Paul L Bishop; John Pile-Spellman Journal: Radiology Date: 2004-12-10 Impact factor: 11.105
Authors: R Santambrogio; E Opocher; A Pisani Ceretti; M Barabino; M Costa; S Leone; M Montorsi Journal: Surg Endosc Date: 2006-11-21 Impact factor: 4.584
Authors: Crispin Schneider; Sean P Johnson; Kurinchi Gurusamy; Richard J Cook; Adrien E Desjardins; David J Hawkes; Brian R Davidson; Simon Walker-Samuel Journal: Lasers Surg Med Date: 2016-12-19 Impact factor: 4.025