Literature DB >> 2022450

Validation of ultrafast computed tomographic left ventricular volume measurement.

R J Pietras1, C J Wolfkiel, K Veselik, E Roig, E V Chomka, B H Brundage.   

Abstract

Left ventricular volume has been measured with ultrafast computed tomography. However, the accuracy with which this can be done is unknown. We therefore imaged with ultrafast computed tomography 11 rectangular phantoms, 20 to 225 ml, and 17 left ventricular casts, 15 to 112 ml. Two observers planimetered serial tomographic images and computed volume from sequential tomograms. There was no significant inter- or intraobserver difference in measurement of phantoms. Deviation of ultrafast computed tomographic volume from true phantom volume was -0.1 +/- 3.5% SD, range 9.0 to -7.6%. Correlation of true phantom volume with ultrafast computed tomographic volume was 0.99, SEE = 1.9 ml. No significant difference was observed between merged and single ultrafast computed tomographic scanning sequences. Left ventricular cast volume determined by ultrafast computed tomography deviated from true volume by 6% +/- 20%, range 54% to -45%. Correlation of true volume with ultrafast computed tomographic volume was 0.99, SEE = 5.1 ml. There was no interobserver significant difference in measurement of left ventricular cast volume. Correlation between ultrafast computed tomographic volume and cineradiographic volume of the same left ventricular casts was 0.99, SEE = 4.4 ml. Thus, phantom volumes can be measured accurately without significant intra- or interobserver variation. Merged scanning sequences did not influence volume determination. Left ventricular cast volume determination was comparable to that obtained with cineradiography.

Entities:  

Mesh:

Year:  1991        PMID: 2022450     DOI: 10.1097/00004424-199101000-00006

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  4 in total

Review 1.  Advances in cardiovascular CT imaging: CT clinical imaging.

Authors:  William Stanford
Journal:  Int J Cardiovasc Imaging       Date:  2005-02       Impact factor: 2.357

2.  Static morphometric bases for CT identification and evaluation of the outflow chamber of the left ventricle. Preliminary study in formalin-fixed heart.

Authors:  R Demaria; G Godlewski; P De Guilhermier; J Tang; J Seguin; P A Chaptal
Journal:  Surg Radiol Anat       Date:  1993       Impact factor: 1.246

3.  Accurate measures of left ventricular ejection fraction using electron beam tomography: a comparison with radionuclide angiography, and cine angiography.

Authors:  H K Baik; M J Budoff; K L Lane; H Bakhsheshi; B H Brundage
Journal:  Int J Card Imaging       Date:  2000-10

4.  Evaluation of left ventricular dysfunction using multiphasic reconstructions of coronary multi-slice computed tomography data in patients with chronic ischemic heart disease: validation against cine magnetic resonance imaging.

Authors:  Sandra S Halliburton; Martin Petersilka; Paulo R Schvartzman; Nancy Obuchowski; Richard D White
Journal:  Int J Cardiovasc Imaging       Date:  2003-02       Impact factor: 2.357

  4 in total