BACKGROUND AND AIMS: The coronal alignment of the lower limb is important for planning and assessing outcome after total knee arthroplasty. This study compared postoperative estimation of alignment and measurement of angles using both hip-to-ankle radiographs and anteroposterior (AP) knee radiographs in standing position. PATIENTS AND METHODS: Consecutive standard AP knee and hip-to-ankle radiographs in 83 patients (103 knees) after total knee arthroplasty were analyzed.
RESULTS: The tibiofemoral angle measured from both hip-to-ankle and knee radiographs correlated moderately with the mechanical axis (r = 0.646 and r = 0.540, respectively). The correlation between tibiofemoral angles in the two radiographs was excellent (r = 0.860). Furthermore, measurements of tibial and femoral component alignment between the two radiographs correlated highly (r = 0.718 and r = 0.773, respectively). Intra- and interobserver correlations were high in all analyses.
CONCLUSIONS: The standard AP knee radiograph appears to be a valid alternative to the hip-to-ankle radiograph for determining knee coronal plane alignment in routine followup after total knee arthroplasty. However, the hip-to-ankle radiograph alone provides accurate information on weight-bearing mechanical axis in patients with suspected lower limb malalignment.

Entities:  

Mesh:

Year:  2009        PMID: 20218424     DOI: 10.1177/145749690909800411

Source DB:  PubMed          Journal:  Scand J Surg        ISSN: 1457-4969            Impact factor:   2.360


  17 in total

1.  Using fibula as a reference can be beneficial for the tibial component alignment after total knee arthroplasty, a retrospective study.

Authors:  Mehmet Erdem; Deniz Gulabi; Gultekin Sitki Cecen; Cem Coskun Avci; Murat Asci; Fevzi Saglam
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-03-25       Impact factor: 4.342

2.  No correlation between coronal alignment of total knee arthroplasty and clinical outcomes: a prospective clinical study using 3D-CT.

Authors:  Omer Slevin; Felix Amsler; Michael T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-12-22       Impact factor: 4.342

3.  Neutral alignment leads to higher knee society scores after total knee arthroplasty in preoperatively non-varus patients: a prospective clinical study using 3D-CT.

Authors:  Omer Slevin; Anna Hirschmann; Filippo F Schiapparelli; Felix Amsler; Rolf W Huegli; Michael T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-10-12       Impact factor: 4.342

4.  Radiographic Evaluation of Alignment Following TKA, a Systematic Review.

Authors:  Serban Dragosloveanu; Bogdan Cretu; Stefan Cristea; Cristian Stoica; Calin Dragosloveanu
Journal:  Maedica (Bucur)       Date:  2017-09

Review 5.  Current evidence base for kinematic alignment.

Authors:  L-R Tuecking; P Savov; H Windhagen; M Ettinger
Journal:  Orthopade       Date:  2020-07       Impact factor: 1.087

6.  Patient-specific computed tomography based instrumentation in total knee arthroplasty: a prospective randomized controlled study.

Authors:  Andrzej Kotela; Ireneusz Kotela
Journal:  Int Orthop       Date:  2014-06-28       Impact factor: 3.075

Review 7.  How to assess femoral and tibial component rotation after total knee arthroplasty with computed tomography: a systematic review.

Authors:  Eduard J De Valk; Julia C A Noorduyn; Eduard L A R Mutsaerts
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-09-21       Impact factor: 4.342

8.  Constitutional varus does not affect joint line orientation in the coronal plane.

Authors:  Jan M K Victor; David Bassens; Johan Bellemans; Sarper Gürsu; Aad A M Dhollander; Peter C M Verdonk
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

9.  A comparison of femoral component rotation after total knee arthroplasty in Kanekasu radiographs, axial CT slices and 3D reconstructed images.

Authors:  Emma L Robertson; Martin Hengherr; Felix Amsler; Michael T Hirschmann; Dominic T Mathis
Journal:  Skeletal Radiol       Date:  2021-01-04       Impact factor: 2.199

10.  Non-weight-bearing short knee radiographs to evaluate coronal alignment before total knee arthroplasty.

Authors:  Sheng Pan; Chaoran Huang; Xingchen Zhang; Ruxin Ruan; Ziwen Yan; Zheng Li; Yong Pang; Kaijin Guo; Xin Zheng
Journal:  Quant Imaging Med Surg       Date:  2022-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.