Aliasing artifacts in computerized tomography.

C R Crawford, A C Kak.   

Abstract

Streaking artifacts in tomographic images reconstructed by the filtered-backprojection algorithm are caused by aliasing errors in the projection data. To show this a computer simulation study was performed in which the transforms of undersampled projections were subtracted from the corresponding transforms when the projection data were taken with a very large number of rays. This yielded the aliased spectrum for the undersampled case. An image was reconstructed from the difference transforms. Streaks present in this image exactly matched those present in the undersampled reconstruction. (The number of projections used in this study was large enough to preclude any artifacts caused by their insufficient number.) We have derived a theoretical upper bound for the energy contained in these aliasing artifacts. In this paper we have also briefly touched upon the artifacts caused by other algorithmic aspects of a tomographic system.

Entities:  

Year:  1979        PMID: 20216673     DOI: 10.1364/AO.18.003704

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  5 in total

1.  Effect of the number of projections collected on quantitative perfusion and left ventricular ejection fraction measurements from gated myocardial perfusion single-photon emission computed tomographic images.

Authors:  G Germano; P B Kavanagh; D S Berman
Journal:  J Nucl Cardiol       Date:  1996 Sep-Oct       Impact factor: 5.952

2.  Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT.

Authors:  Junguo Bian; Jeffrey H Siewerdsen; Xiao Han; Emil Y Sidky; Jerry L Prince; Charles A Pelizzari; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2010-10-20       Impact factor: 3.609

3.  Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

Authors:  A Sisniega; W Zbijewski; J W Stayman; J Xu; K Taguchi; E Fredenberg; Mats Lundqvist; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-11-27       Impact factor: 3.609

4.  Cubic-Spline Interpolation for Sparse-View CT Image Reconstruction With Filtered Backprojection in Dynamic Myocardial Perfusion Imaging.

Authors:  Esmaeil Enjilela; Ting-Yim Lee; Gerald Wisenberg; Patrick Teefy; Rodrigo Bagur; Ali Islam; Jiang Hsieh; Aaron So
Journal:  Tomography       Date:  2019-09

5.  Bone-induced streak artifact suppression in sparse-view CT image reconstruction.

Authors:  Seung Oh Jin; Jae Gon Kim; Soo Yeol Lee; Oh-Kyong Kwon
Journal:  Biomed Eng Online       Date:  2012-08-02       Impact factor: 2.819