Literature DB >> 20213299

Vertebroplasty with self-locking hexagonal metal implants shows comparable primary and secondary stiffness to PMMA cement augmentation techniques in a biomechanical vertebral compression fracture model.

W Schmoelz1, A C Disch, J F Huber.   

Abstract

With the growing incidence of vertebral compression fractures in elderly patients having a fair overall health condition, minimal-invasive treatment techniques are getting in focus of surgical therapy. Cement augmentation is widely performed and its complications and mechanical limitations are well described. Implants avoiding the side effects of cement augmentation while reaching the same level of stability would be desirable. The primary and secondary stability of a new augmentation method with self-locking hexagonal metal implants were investigated and compared with the performance of established augmentation options. 18 fresh-frozen human spinal specimens (Th12-L2/L3-L5) were tested with pure moments of 7.5 Nm in a six-degree-of-freedom spine simulator to investigate primary and secondary stability of three augmentation techniques: (1) vertebroplasty, (2) PMMA filled cavity and (3) hexagonal metal implants. An increasing three-step cyclic loading model was included. Elastic displacement and height loss under loading did not show significant differences between the three test groups. Investigation of primary and secondary stability evenly demonstrated comparable results for all techniques indicating an insufficiency to stabilise the fracture with higher load cycles. The newly introduced method for augmentation with the metal implant Spine Pearls achieved comparable results to bone cement based techniques in a biomechanical in vitro study. Midterm and longterm reduction preservation and ingrowth of the implants have to be proven in further studies.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20213299      PMCID: PMC2899983          DOI: 10.1007/s00586-010-1342-9

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  40 in total

Review 1.  Osseointegration of cemented and noncemented implants in artificial hip replacement: long-term findings in man.

Authors:  H G Willert; G H Buchhorn
Journal:  J Long Term Eff Med Implants       Date:  1999

2.  Biomechanical evaluation of kyphoplasty with calcium sulfate cement in a cadaveric osteoporotic vertebral compression fracture model.

Authors:  Andrew Perry; Andrew Mahar; Jennifer Massie; Noemi Arrieta; Steven Garfin; Choll Kim
Journal:  Spine J       Date:  2005 Sep-Oct       Impact factor: 4.166

3.  Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants.

Authors:  H J Wilke; K Wenger; L Claes
Journal:  Eur Spine J       Date:  1998       Impact factor: 3.134

4.  [Histology of the implant-bone interface in cemented and uncemented endoprostheses].

Authors:  T Herren; W Remagen; R Schenk
Journal:  Orthopade       Date:  1987-06       Impact factor: 1.087

5.  Vertebroplasty by use of a strontium-containing bioactive bone cement.

Authors:  Kenneth M C Cheung; William W Lu; Keith D K Luk; C T Wong; Danny Chan; J X Shen; G X Qiu; Z M Zheng; C H Li; S L Liu; W K Chan; John C Y Leong
Journal:  Spine (Phila Pa 1976)       Date:  2005-09-01       Impact factor: 3.468

6.  Biomechanical time-tolerance of fresh cadaveric human spine specimens.

Authors:  M M Panjabi; M Krag; D Summers; T Videman
Journal:  J Orthop Res       Date:  1985       Impact factor: 3.494

Review 7.  Tumors of the osseous spine.

Authors:  Narayan Sundaresan; Stephano Boriani; Allen Rothman; Robert Holtzman
Journal:  J Neurooncol       Date:  2004 Aug-Sep       Impact factor: 4.130

8.  Balloon kyphoplasty for the treatment of pathological vertebral compressive fractures.

Authors:  Ioannis N Gaitanis; Alexander G Hadjipavlou; Pavlos G Katonis; Michael N Tzermiadianos; Dritan S Pasku; Avinash G Patwardhan
Journal:  Eur Spine J       Date:  2004-10-08       Impact factor: 3.134

9.  Biomechanical analysis of experimental spinal cord injury and functional loss.

Authors:  M M Panjabi; J R Wrathall
Journal:  Spine (Phila Pa 1976)       Date:  1988-12       Impact factor: 3.468

Review 10.  The current treatment--a survey of osteoporotic fracture treatment. Osteoporotic spine fractures: the spine surgeon's perspective.

Authors:  Paul F Heini
Journal:  Osteoporos Int       Date:  2004-09-09       Impact factor: 4.507

View more
  5 in total

1.  Construct stability of an instrumented 2-level cervical corpectomy model following fatigue testing: biomechanical comparison of circumferential antero-posterior instrumentation versus a novel anterior-only transpedicular screw-plate fixation technique.

Authors:  Heiko Koller; Werner Schmoelz; Juliane Zenner; Alexander Auffarth; Herbert Resch; Wolfgang Hitzl; Davud Malekzadeh; Lukas Ernstbrunner; Martina Blocher; Michael Mayer
Journal:  Eur Spine J       Date:  2015-01-23       Impact factor: 3.134

2.  The implantation of a Nickel-Titanium shape memory alloy ameliorates vertebral body compression fractures: a cadaveric study.

Authors:  Bo Chen; Yue-Huang Zheng; Tao Zheng; Chang-Hui Sun; Jiong Lu; Peng Cao; Jian-Hua Zhou
Journal:  Int J Clin Exp Med       Date:  2015-09-15

Review 3.  [Biomechanical aspects of vertebral augmentation].

Authors:  H-J Wilke
Journal:  Unfallchirurg       Date:  2015-10       Impact factor: 1.000

4.  Local osteo-enhancement of osteoporotic vertebra with a triphasic bone implant material increases strength-a biomechanical study.

Authors:  Matthias Trost; Werner Schmoelz; Doris Wimmer; Romed Hörmann; Sönke Frey; Tobias Ludger Schulte
Journal:  Arch Orthop Trauma Surg       Date:  2020-02-27       Impact factor: 3.067

Review 5.  A 20-Year Review of Biomechanical Experimental Studies on Spine Implants Used for Percutaneous Surgical Repair of Vertebral Compression Fractures.

Authors:  Sairam Gajavelli; Aaron Gee; Z Shaghayegh Bagheri; Emil H Schemitsch; Christopher S Bailey; Parham Rasoulinejad; Radovan Zdero
Journal:  Biomed Res Int       Date:  2022-09-21       Impact factor: 3.246

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.