Literature DB >> 20206357

Non-invasive assessment of soft-tissue artifact and its effect on knee joint kinematics during functional activity.

Massoud Akbarshahi1, Anthony G Schache, Justin W Fernandez, Richard Baker, Scott Banks, Marcus G Pandy.   

Abstract

The soft-tissue interface between skin-mounted markers and the underlying bones poses a major limitation to accurate, non-invasive measurement of joint kinematics. The aim of this study was twofold: first, to quantify lower limb soft-tissue artifact in young healthy subjects during functional activity; and second, to determine the effect of soft-tissue artifact on the calculation of knee joint kinematics. Subject-specific bone models generated from magnetic resonance imaging (MRI) were used in conjunction with X-ray images obtained from single-plane fluoroscopy to determine three-dimensional knee joint kinematics for four separate tasks: open-chain knee flexion, hip axial rotation, level walking, and a step-up. Knee joint kinematics was derived using the anatomical frames from the MRI-based, 3D bone models together with the data from video motion capture and X-ray fluoroscopy. Soft-tissue artifact was defined as the degree of movement of each marker in the anteroposterior, proximodistal and mediolateral directions of the corresponding anatomical frame. A number of different skin-marker clusters (total of 180) were used to calculate knee joint rotations, and the results were compared against those obtained from fluoroscopy. Although a consistent pattern of soft-tissue artifact was found for each task across all subjects, the magnitudes of soft-tissue artifact were subject-, task- and location-dependent. Soft-tissue artifact for the thigh markers was substantially greater than that for the shank markers. Markers positioned in the vicinity of the knee joint showed considerable movement, with root mean square errors as high as 29.3mm. The maximum root mean square errors for calculating knee joint rotations occurred for the open-chain knee flexion task and were 24.3 degrees , 17.8 degrees and 14.5 degrees for flexion, internal-external rotation and abduction-adduction, respectively. The present results on soft-tissue artifact, based on fluoroscopic measurements in healthy adult subjects, may be helpful in developing location- and direction-specific weighting factors for use in global optimization algorithms aimed at minimizing the effects of soft-tissue artifact on calculations of knee joint rotations. Copyright 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20206357     DOI: 10.1016/j.jbiomech.2010.01.002

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  35 in total

1.  Are the kinematics of the knee joint altered during the loading response phase of gait in individuals with concurrent knee osteoarthritis and complaints of joint instability? A dynamic stereo X-ray study.

Authors:  Shawn Farrokhi; Scott Tashman; Alexandra B Gil; Brian A Klatt; G Kelley Fitzgerald
Journal:  Clin Biomech (Bristol, Avon)       Date:  2011-11-08       Impact factor: 2.063

2.  In vitro quantification of the performance of model-based mono-planar and bi-planar fluoroscopy for 3D joint kinematics estimation.

Authors:  Luca Tersi; Arnaud Barré; Silvia Fantozzi; Rita Stagni
Journal:  Med Biol Eng Comput       Date:  2012-11-11       Impact factor: 2.602

3.  Kinematic description of soft tissue artifacts: quantifying rigid versus deformation components and their relation with bone motion.

Authors:  Helios de Rosario; Alvaro Page; Antonio Besa; Vicente Mata; Efraim Conejero
Journal:  Med Biol Eng Comput       Date:  2012-10-26       Impact factor: 2.602

4.  Stretch and activation of the human biarticular hamstrings across a range of running speeds.

Authors:  Anthony G Schache; Tim W Dorn; Tim V Wrigley; Nicholas A T Brown; Marcus G Pandy
Journal:  Eur J Appl Physiol       Date:  2013-09-08       Impact factor: 3.078

5.  Comparison of Marker-Based and Stereo Radiography Knee Kinematics in Activities of Daily Living.

Authors:  Donald R Hume; Vasiliki Kefala; Michael D Harris; Kevin B Shelburne
Journal:  Ann Biomed Eng       Date:  2018-06-14       Impact factor: 3.934

6.  Error performances of a model-based biplane fluoroscopic system for tracking knee prosthesis during treadmill gait task.

Authors:  Arnaud Barré; Kamiar Aminian
Journal:  Med Biol Eng Comput       Date:  2017-07-18       Impact factor: 2.602

7.  Validation of a method to accurately correct anterior superior iliac spine marker occlusion.

Authors:  Joshua T Hoffman; Michael P McNally; Samuel C Wordeman; Timothy E Hewett
Journal:  J Biomech       Date:  2015-02-03       Impact factor: 2.712

8.  Gait analysis in children with cerebral palsy via inertial and magnetic sensors.

Authors:  Josien C van den Noort; Alberto Ferrari; Andrea G Cutti; Jules G Becher; Jaap Harlaar
Journal:  Med Biol Eng Comput       Date:  2012-12-09       Impact factor: 2.602

9.  The inaccuracy of surface-measured model-derived tibiofemoral kinematics.

Authors:  Kang Li; Liying Zheng; Scott Tashman; Xudong Zhang
Journal:  J Biomech       Date:  2012-09-08       Impact factor: 2.712

10.  A Wearable Magnet-Based System to Assess Activity and Joint Flexion in Humans and Large Animals.

Authors:  Feini Qu; Brendan D Stoeckl; Peter M Gebhard; Todd J Hullfish; Josh R Baxter; Robert L Mauck
Journal:  Ann Biomed Eng       Date:  2018-08-06       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.